Optical and x-ray streak camera gain measurements

被引:8
|
作者
Ghosh, S [1 ]
Boni, R [1 ]
Jaanimagi, PA [1 ]
机构
[1] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2004年 / 75卷 / 10期
关键词
D O I
10.1063/1.1787929
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Measurements of streak camera gain as the number of CCD (charge-coupled-device) electrons recorded per single-electron events hitting the streak tube phosphor are presented. The CCD is fiber optically coupled to the streak tube output; there is no image intensifier in the system. The gain is measured from the signal-to-noise ratio (SNR) of the recorded photoelectrons. This technique allows us to verify that the photoelectron SNR follows Poisson statistics and to establish the linear dynamic range. Superpixel histograms of sparse streak records are also used to generate the pulse-height distribution (PHD) for recording single-electron events and corroborate the gain measurement. The noise factor and the number distribution of secondary electrons emitted per absorbed x ray from Au, KBr, and CsI photocathodes are derived from the PHD's recorded with an x-ray streak camera. (C) 2004 American Institute of Physics.
引用
收藏
页码:3956 / 3958
页数:3
相关论文
共 50 条
  • [42] Demonstration of a sub-picosecond x-ray streak camera
    Chang, Z
    Rundquist, A
    Zhou, J
    Murnane, MM
    Kapteyn, HC
    Liu, X
    Shan, B
    Liu, J
    Niu, L
    Gong, M
    Zhang, X
    APPLIED PHYSICS LETTERS, 1996, 69 (01) : 133 - 135
  • [43] Signal averaging x-ray streak camera with picosecond jitter
    Maksimchuk, A.
    Kim, M.
    Workman, J.
    Korn, G.
    Squier, J.
    Du, D.
    Umstadter, D.
    Mourou, G.
    Bouvier, M.
    Review of Scientific Instruments, 1996, 67 (3 pt 1): : 697 - 699
  • [44] Performance of a CsI photocathode in a hard x-ray streak camera
    Hara, T
    Tanaka, Y
    Kitamura, H
    Ishikawa, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (10): : 3624 - 3626
  • [45] X-CHRON-540 - A NEW PICOSECOND X-RAY STREAK CAMERA
    HADLAND, R
    BOWLEY, D
    HONOUR, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 1090 - 1094
  • [46] OPTICAL FIDUCIALS FOR X-RAY STREAK CAMERAS AT LLE
    JAANIMAGI, PA
    DASILVA, L
    GREGORY, GG
    HESTDALEN, C
    KIIKKA, CD
    KOTMEL, R
    RICHARDSON, MC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (08): : 2189 - 2191
  • [47] Observation of hard X-ray pulses with a highly sensitive streak camera
    Hara, T
    Tanaka, Y
    Kitamura, H
    Ishikawa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1125 - 1128
  • [48] Design of a sub 100-femtosecond X-ray Streak Camera
    Li, Bin
    Rajeev, P. P.
    Gregori, G.
    Benetou, M.
    Dobson, B.
    Cavalleri, A.
    Pickworth, L.
    Lau, P.
    Jaanimagi, P.
    Read, F.
    Lynn, J.
    Neely, D.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 2456 - +
  • [49] Image plate and X-ray streak camera precision coupling technology
    Yang, Z. (yzh@caep.ac.cn), 1600, Editorial Office of High Power Laser and Particle Beams, P.O. Box 919-805, Mianyang, 621900, China (24):
  • [50] Characterization of the new FX1 x-ray streak camera
    Pitre, V
    Magnan, S
    Kieffer, JC
    Dorchies, F
    Salin, F
    Goulmy, C
    Rebuffie, JC
    FOURTH-GENERATION X-RAY SOURCES AND ULTRAFAST X-RAY DETECTORS, 2004, 5194 : 115 - 122