Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel

被引:0
|
作者
Puurtinen, Merja M. [1 ]
Komulainen, Satu M. [1 ]
Kauppinen, Pasi K. [1 ]
Malmivuo, Jaakko A. V. [1 ]
Hyttinen, Jari A. K. [1 ]
机构
[1] Tampere Univ Technol, Ragnar Granit Inst, PO Box 692, FIN-33101 Tampere, Finland
基金
芬兰科学院;
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Textile sensors, when embedded into clothing, can provide new ways of monitoring physiological signals, and improve the usability and comfort of such monitoring systems in the areas of medical, occupational health and sports. However, good electrical and mechanical contact between the electrode and the skin is very important, as it often determines the quality of the signal. This paper introduces a study where the properties of dry textile electrodes, textile electrodes moistened with water, and textile electrodes covered with hydrogel were studied with five different electrode sizes. The aim was to study how the electrode size and preparation of the electrode (dry electrode / wet electrode / electrode covered with hydrogel membrane) affect the measurement noise, and the skin-electrode impedance. The measurement noise and skin-electrode impedance were determined from surface biopotential measurements. These preliminary results indicate that noise level increases as the electrode size decreases. The noise level is high in dry textile electrodes, as expected. Yet, the noise level of wet textile electrodes is quite low and similar to that of textile electrodes covered with hydrogel. flydrogel does not seem to improve noise properties, however it may have effects on movement artifacts. Thus, it is feasible to use textile embedded sensors in physiological monitoring applications when moistening or hydrogel is applied.
引用
收藏
页码:3335 / +
页数:2
相关论文
共 50 条
  • [1] Dry Wearable Textile Electrodes for Portable Electrical Impedance Tomography
    Hu, Chang-Lin
    Cheng, I-Cheng
    Huang, Chih-Hsien
    Liao, Yu-Te
    Lin, Wei-Chieh
    Tsai, Kun-Ju
    Chi, Chih-Hsien
    Chen, Chang-Wen
    Wu, Chia-Hsi
    Lin, I-Te
    Li, Chien-Ju
    Lin, Chii-Wann
    SENSORS, 2021, 21 (20)
  • [2] Dry Textile Electrodes for Wearable Bio-Impedance Analyzers
    Corchia, Laura
    Monti, Giuseppina
    Raheli, Federica
    Candelieri, Giulia
    Tarricone, Luciano
    IEEE SENSORS JOURNAL, 2020, 20 (11) : 6139 - 6147
  • [3] Textile electrodes in ECG measurement
    Pola, Taina
    Vanhala, Jukka
    PROCEEDINGS OF THE 2007 INTERNATIONAL CONFERENCE ON INTELLIGENT SENSORS, SENSOR NETWORKS AND INFORMATION PROCESSING, 2007, : 635 - +
  • [4] Impedance pneumography using textile electrodes
    Fiedler, P.
    Biller, S.
    Griebel, S.
    Haueisen, J.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1606 - 1609
  • [5] Noise performance of textile-based dry ECG recording electrodes
    Maji, Soumyajyoti
    Burke, Martin J.
    ELECTRONICS LETTERS, 2021, 57 (02) : 45 - 48
  • [6] Analysis of Consistency of Transthoracic Bioimpedance Measurements Acquired with Dry Carbon Black PDMS Electrodes, Adhesive Electrodes, and Wet Textile Electrodes
    Posada-Quintero, Hugo F.
    Reljin, Natasa
    Eaton-Robb, Caitlin
    Noh, Yeonsik
    Riistama, Jarno
    Chon, Ki H.
    SENSORS, 2018, 18 (06)
  • [7] Impedance evaluation of textile electrodes for EEG measurements
    Rahman, S. M. Musfequr
    Mattila, Henna
    Janka, Marika
    Virkki, Johanna
    TEXTILE RESEARCH JOURNAL, 2023, 93 (7-8) : 1878 - 1888
  • [8] WEARABLE TEXTILE ELECTRODES FOR ECG MEASUREMENT
    Vojtech, Lukas
    Bortel, Radoslav
    Neruda, Marek
    Kozak, Milos
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2013, 11 (05) : 410 - 414
  • [9] Biological signal measurement using stretchable dry electrodes printed on textile substrates
    Inoue M.
    Tada Y.
    Amano Y.
    Itabashi Y.
    Sato T.
    Saito S.
    Inoue, Masahiro (masa-inoue@gunma-u.ac.jp), 1600, Institute of Electrical Engineers of Japan (136): : 18 - 23
  • [10] Quality control of textile electrodes by electrochemical impedance spectroscopy
    Westbroek, P
    Priniotakis, G
    Palovuori, E
    De Clerck, K
    Van Langenhove, L
    Kiekens, P
    TEXTILE RESEARCH JOURNAL, 2006, 76 (02) : 152 - 159