Impedance pneumography using textile electrodes

被引:0
|
作者
Fiedler, P. [1 ]
Biller, S. [1 ]
Griebel, S.
Haueisen, J. [1 ]
机构
[1] Ilmenau Univ Technol, Inst Biomed Engn & Informat, D-98684 Ilmenau, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The acquisition of physiological parameters using textile and textile-integrated sensors has become an important alternative for mobile and long-term monitoring. We analyzed to different commercially available electrically conductive textiles concerning their applicability for textile-based impedance pneumography. We immersed the textiles to four corroding solutions and observed no considerable changes in the absolute value as well as the phase shift of the material impedances. Subsequently, we performed impedance pneumography tests with different current amplitudes and frequencies. Using silver coated synthetic textile electrodes it was possible to detect the correct respiration frequency during normal, flat as well as slow, deep respiration.
引用
收藏
页码:1606 / 1609
页数:4
相关论文
共 50 条
  • [1] Evaluation of Respiratory Signal Record Based on Impedance Pneumography and Textile Electrodes
    Ruben Dell'Aquila, Carlos
    Eduardo Canadas, Gabriel
    Laciar, Eric
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1502 - 1509
  • [2] Movement artefact rejection in impedance pneumography using six strategically placed electrodes
    Khambete, ND
    Brown, BH
    Smallwood, RH
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) : 79 - 88
  • [3] Electrode Comparison for Textile-Integrated Electrocardiogram and Impedance Pneumography Measurement
    Tuohimaki, K.
    Mahdiani, S.
    Jeyhani, V.
    Vehkaoja, A.
    Iso-Ketola, P.
    Vanhala, J.
    Viik, J.
    Mantysalo, M.
    EMBEC & NBC 2017, 2018, 65 : 302 - 305
  • [4] IMPEDANCE PNEUMOGRAPHY
    NORTH, JB
    JENNETT, S
    LANCET, 1972, 2 (7781): : 828 - &
  • [5] IMPEDANCE PNEUMOGRAPHY
    HECK, AF
    REICHL, W
    HALL, VR
    LANCET, 1972, 2 (7780): : 758 - &
  • [6] Assessment of Pulmonary Flow Using Impedance Pneumography
    Seppa, Ville-Pekka
    Viik, Jari
    Hyttinen, Jari
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (09) : 2277 - 2285
  • [7] Graphene electrodes for long-term impedance pneumography - a feasibility study
    Mlynczak, Marcel
    Zylinski, Marek
    Janczak, Daniel
    Jakubowska, Malgorzata
    Niewiadomski, Wiktor
    Cybulski, Gerard
    EMBEC & NBC 2017, 2018, 65 : 514 - 517
  • [8] RHEOPNEUMOGRAPHY (IMPEDANCE PNEUMOGRAPHY)
    LUKYANOV, EK
    ANOKHIN, MI
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE,USSR, 1966, 62 (09): : 1074 - &
  • [9] Impedance pneumography - is it possible?
    Mlynczak, Marcel
    Cybulski, Gerard
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2012, 2012, 8454
  • [10] Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel
    Puurtinen, Merja M.
    Komulainen, Satu M.
    Kauppinen, Pasi K.
    Malmivuo, Jaakko A. V.
    Hyttinen, Jari A. K.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3335 - +