摘要
A platinum electrode with its surface modified with the condensation product of p-phenylenediamine and acetylferrocene (PPDA-AcFc) has been fabricated by cyclic voltammetry. The square wave voltammogram of the modified electrode, PPDA-AcFc/Pt, in aqueous medium gradually shifts by 0.440 V and 0.090 V in the positive direction on interaction with Al3+ and Pb2+ respectively. Electrochemical impedance spectroscopy shows the charge transfer resistance value of PPDA-AcFc/Pt electrode increases in the case of Al3+ while it decreases in the case of Pb2+. The linear range of detection is 0-12 mu M and 0-6 mu M for Al3+ and Pb2+ respectively.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 50 条
  • [1] A Novel Chitosan Nanoparticle-Schiff Base Modified Carbon Paste Electrode as a Sensor for the Determination of Pb(II) in Waste Water
    Kucukkolbasi, Semahat
    Erdogan, Zehra Ozden
    Barek, Jiri
    Sahin, Mustafa
    Kocak, Nuriye
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 2164 - 2181
  • [2] A single schiff base molecule for recognizing multiple metal ions: A fluorescence sensor for Zn(II) and Al(III) and colorimetric sensor for Fe(II) and Fe(III)
    Choi, Ye Won
    Park, Gyeong Jin
    Na, Yu Jeong
    Jo, Hyun Yong
    Lee, Seul Ah
    You, Ga Rim
    Kim, Cheal
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 194 : 343 - 352
  • [3] Antipyrine derived Schiff base: A colurimetric sensor for Fe(III) and "turn-on" fluorescent sensor for Al(III)
    Soufeena, P. P.
    Aravindakshan, K. K.
    JOURNAL OF LUMINESCENCE, 2019, 205 : 400 - 405
  • [4] New Pb(II)-selective membrane electrode based on a new Schiff base complex
    Yuan, Xiao-Ju
    Wang, Rui-Ying
    Mao, Chun-Bo
    Wu, Lian
    Chu, Cai-Qing
    Yao, Rui
    Gao, Zhi-Yang
    Wu, Ben-Lai
    Zhang, Hong-Yun
    INORGANIC CHEMISTRY COMMUNICATIONS, 2012, 15 : 29 - 32
  • [5] Use of a Schiff base-modified conducting polymer electrode for electrochemical assay of Cd(II) and Pb(II) ions by square wave voltammetry
    Mohammed Q. Mohammed
    Hani K. Ismail
    Hasan F. Alesary
    Stephen Barton
    Chemical Papers, 2022, 76 : 715 - 729
  • [6] Use of a Schiff base-modified conducting polymer electrode for electrochemical assay of Cd(II) and Pb(II) ions by square wave voltammetry
    Mohammed, Mohammed Q.
    Ismail, Hani K.
    Alesary, Hasan F.
    Barton, Stephen
    CHEMICAL PAPERS, 2022, 76 (02) : 715 - 729
  • [7] Schiff base modified screen printed electrode for selective determination of aluminium(III) at trace level
    Rana, Sonia
    Mittal, Susheel K.
    Singh, Narinder
    Singh, Jasminder
    Banks, Craig E.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 17 - 27
  • [8] The preparation and application of Schiff base chitosan modified electrode
    Liu, B
    Sun, XY
    Jinrui, X
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (09) : 1048 - 1052
  • [9] Synthesis and characterization of Schiff base derivatives of bimetallic [Mg(II); Al(III)]-μ-oxoisopropoxide
    Sharma, HK
    Kapoor, PN
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2004, 43 (03): : 566 - 568
  • [10] Efficient removal of Pb(II) using modified chitosan Schiff base@Fe/NiFe
    Jasim, Saade Abdalkareem
    Hachem, Kadda
    Abdelbasset, Walid Kamal
    Yasin, Ghulam
    Suksatan, Wanich
    Chem, Cui
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2022, 204 : 644 - 651