Validity and Reliability of the New Portable Metabolic Analyzer PNOE

被引:29
|
作者
Tsekouras, Yiannis E. [1 ]
Tambalis, Konstantinos D. [1 ]
Sarras, Stavros E. [1 ]
Antoniou, Athanasios K. [1 ]
Kokkinos, Peter [2 ,3 ,4 ]
Sidossis, Labros S. [1 ,2 ,5 ]
机构
[1] Harokopio Univ, Sch Hlth Sci & Educ, Dept Nutr & Dietet, Athens, Greece
[2] Rutgers State Univ, Dept Kinesiol & Hlth, New Brunswick, NJ USA
[3] Vet Affairs Med Ctr, Dept Cardiol, 50 Irving St NW, Washington, DC 20422 USA
[4] Georgetown Univ, Sch Med, Washington, DC USA
[5] Rutgers State Univ, Robert Wood Johnson Med Sch, Dept Med, New Brunswick, NJ 08854 USA
来源
关键词
indirect calorimetry; breath-by-breath analysis; validity; reliability assessment; portable metabolic measuring system; COSMED K4 B(2); OXYGEN-UPTAKE; EXERCISE; ACCURACY; SYSTEM; VALIDATION; FITNESS;
D O I
10.3389/fspor.2019.00024
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Assessment of the oxygen and carbon dioxide content of expired air during exercise is critical for determining cardiorespiratory status. The purpose of this study was to compare the new portable metabolic analyzer PNOE with COSMED - Quark CPET, a previously validated stationary metabolic cart. Methods: A total of 22 subjects (17 male and 5 female) aged 32.3 +/- 11.1 years took part in the study. Breath by breath gas exchange was measured by both devices during a four-stage incremental protocol on a cycle ergometer. On a separate day, 10 participants repeated the trial to assess the reliability of the PNOE metabolic cart. Results: Strong correlations were obtained in VO2 (r = 0.98, p < 0.001), VCO2 (r = 0.98, p < 0.001), VE (r = 0.98, p < 0.001), and RQ (r = 0.91, p < 0.001), between the two devices. Bland-Altman plots revealed a mean difference of 34.0 +/- 118 ml/min and 36.4 +/- 110 ml/min in VO2 and VCO2 analysis, respectively. There were no significant differences in VO2, VCO2, VE, or RQ between the two devices. Intraclass correlation coefficient was high between the two trials for VO2 (r = 0.98, p < 0.001), VCO2 (r = 0.98, p < 0.001), VE (r = 0.99, p < 0.001), and RQ (r = 0.93, p < 0.001). Conclusions: Our data indicate that the portable metabolic cart PNOE can accurately determine respiratory gases over a wide range of exercise intensities, in healthy individuals, in a controlled laboratory setting.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] NEW PORTABLE SOUND AND VIBRATION ANALYZER
    FARAN, JJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1959, 31 (06): : 843 - 843
  • [12] Validity of the VmaxST portable metabolic measurement system
    Laurent, C. Matthew
    Meyers, Michael C.
    Robinson, Clay A.
    Strong, Lorna R.
    Chase, Charles
    Goodwin, Beelee
    JOURNAL OF SPORTS SCIENCES, 2008, 26 (07) : 709 - 716
  • [13] Using a Contemporary Portable Metabolic Gas Exchange System for Assessing Energy Expenditure: A Validity and Reliability Study
    McClung, Holly L.
    Tharion, William J.
    Walker, Leila A.
    Rome, Maxwell N.
    Hoyt, Reed W.
    Looney, David P.
    SENSORS, 2023, 23 (05)
  • [14] Validity and Reliability of the Posturographic Outcomes of a Portable Balance Board
    Meier, Patricia
    Calisti, Maite
    Werner, Inge
    Debertin, Daniel
    Mayer-Suess, Lukas
    Knoflach, Michael
    Federolf, Peter
    SENSORS, 2025, 25 (05)
  • [15] Reliability of the VmaxST Portable Metabolic Measurement System
    Blessinger, J.
    Sawyer, B.
    Davis, C.
    Irving, B. A.
    Weltman, A.
    Gaesser, G.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2009, 30 (01) : 22 - 26
  • [16] NEW PORTABLE CENTRIFUGAL ANALYZER WITH EXPANDED VERSATILITY
    MROCHEK, JE
    BURTIS, CA
    JOHNSON, WF
    BAUER, ML
    LAKOMY, DG
    GENUNG, RK
    SCOTT, CD
    CLINICAL CHEMISTRY, 1977, 23 (08) : 1416 - 1426
  • [17] New portable analyzer monitors power quality
    不详
    HYDROCARBON PROCESSING, 1999, 78 (01): : 38 - 38
  • [18] Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord)
    Akarcesme, Cengiz
    Cengizel, Elif
    Alvurdu, Sumer
    Bagci, Emre
    Altundag, Emre
    Cengizel, Cagdas Ozgur
    Senel, Omer
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2024,
  • [19] Reliability and Validity of a New Portable Tethered Sprint Running Test as a Measure of Maximal Anaerobic Performance
    Limmer, Mirjam
    Berkholz, Alina
    de Marees, Markus
    Platen, Petra
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2020, 34 (08) : 2197 - 2204
  • [20] Validity of a Portable Glucose, Total Cholesterol, and Triglycerides Multi-Analyzer in Adults
    Coqueiro, Raildo da Silva
    Santos, Mateus Carmo
    Leal Neto, Joao de Souza
    de Queiroz, Bruno Morbeck
    Jardim Bruegger, Nelson Augusto
    Barbosa, Aline Rodrigues
    BIOLOGICAL RESEARCH FOR NURSING, 2014, 16 (03) : 288 - 294