Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management

被引:61
|
作者
Cooper, JM
Stephenson, EA
Berul, CI
Walsh, EP
Epstein, LM
机构
[1] Brigham & Womens Hosp, Div Cardiovasc, Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Boston Childrens Hosp, Boston, MA USA
关键词
lasers; congenital heart defects; children; sudden death; ventricularfibrillation; ventricular tachycardia;
D O I
10.1046/j.1540-8167.2003.02500.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ICD Lead Complications in Children with CHD. introduction: Implantable cardioverter defibrillators (ICDs) are being implanted for primary and secondary prevention of sudden death in children and young adults with congenital heart disease. Over time, ICD leads adhere to venous endothelium and endocardium. Lead removal, when necessary, often requires disruption of this fibrous tissue. Methods and Results: We retrospectively reviewed and analyzed our experience with ICD lead extraction in children and young adults with congenital heart disease. From April 1999 through January 2002, 14 patients underwent 15 lead extraction procedures to remove 21 leads (17 ICD leads and 4 pacing or sensing leads). Seven patients had surgically corrected structural heart disease (5 transposition of the great arteries with atrial switch repair and 2 corrected tetralogy of Fallot). Mean patient age at extraction was 17.9 +/- 5.7 years (range 9-32), and mean duration of lead implantation was 42.0 +/- 18.9 months (range 15-75). Fourteen of 15 procedures were performed for lead fracture or failure. A laser sheath was used for 20 of 21 lead extractions. Twenty of 21 leads (95%) were completely extracted. There were three instances of blood loss requiring transfusion. There were no major complications or deaths. Conclusion: Young congenital heart disease patients with an ICD are at risk for growth-related lead distortion. The use of a laser sheath is safe and effective for ICD lead extraction in congenital heart disease patients, despite coil adherence and altered anatomy. It may be advisable to avoid dual-coil leads in patients with the potential for future growth.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [21] Transvenous coronary sinus and implantable cardioverter defibrillator lead extraction: different difficulties and complications
    Dovellini, E. V.
    Giurlani, L.
    Corsi, P.
    Michelucci, A.
    Cerisano, G. P.
    Valenti, R.
    Antoniucci, D.
    EUROPEAN HEART JOURNAL, 2015, 36 : 172 - 172
  • [22] Implantable cardioverter-defibrillator in children and young adolescents: potential benefit and complications
    Gradaus, R
    Wollmann, C
    Koebel, J
    Hammel, D
    Kotthoff, S
    Block, M
    Breithardt, G
    Boecker, D
    EUROPEAN HEART JOURNAL, 2003, 24 : 278 - 278
  • [23] Narrative review of: risk stratification and implantable cardioverter-defibrillator therapy in adults with congenital heart disease
    Koebe, Julia
    Willy, Kevin
    Eckardt, Lars
    Baumgartner, Helmut
    Wasmer, Kristina
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2021, 11 (02) : 538 - 549
  • [24] Characteristics of hospital admissions associated with implantable cardioverter defibrillator placement among adults with congenital heart disease
    Baskar, Shankar
    Veldtman, Gruschen R.
    Khoury, Philip R.
    Opotowsky, Alexander R.
    Cedars, Ari M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 269 : 97 - 103
  • [25] THE RISK OF SUDDEN CARDIAC DEATH IN ADULT CONGENITAL HEART DISEASE: IMPLICATIONS FOR IMPLANTABLE CARDIOVERTER DEFIBRILLATOR THERAPY
    Koyak, Zeliha
    Mulder, Barbara
    Zwinderman, Aeilko
    Harris, Louise
    Oechslin, Erwin
    Bouma, Berto
    Silversides, Candice
    Budts, Werner
    Van Gelder, Isabelle
    de Groot, Joris R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E531 - E531
  • [26] Detection and management of an implantable cardioverter defibrillator lead failure - Incidence and clinical implications
    Ellenbogen, KA
    Wood, MA
    Shepard, RK
    Clemo, HF
    Vaughn, T
    Holloman, K
    Dow, M
    Leffler, J
    Abeyratne, A
    Verness, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (01) : 73 - 80
  • [27] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR OUTCOMES IN PEDIATRIC AND CONGENITAL HEART DISEASE: IT'S COMPLICATED
    Dechert, Brynn
    Bradley, David J.
    Serwer, Gerald A.
    Dick, Macdonald, II
    LaPage, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A575 - A575
  • [28] Implantable Cardioverter Defibrillator Therapy in a Mixed Adult Congenital Heart Disease Population
    Joyce, E.
    O'Brien, C.
    Buckley, U.
    Keaney, J.
    Doran, E.
    Savage, R.
    Walsh, K.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S402 - S403
  • [29] EFFICACY OF IMPLANTABLE CARDIOVERTER DEFIBRILLATORS IN ADULTS WITH CONGENITAL HEART DISEASE
    Koyak, Zeliha
    De Groot, Joris R.
    Van Gelder, Isabelle C.
    Budts, Werner
    Van Erven, Lieselot
    Van Dessel, Pascal F. H. M.
    Van Dijk, Arie
    Smeets, Joep L. R. M.
    Maass, Alexander H.
    Wilde, Arthur A. M.
    Pieper, Petronella G.
    Mulder, Barbara J. M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E407 - E407
  • [30] Implantable-Cardioverter Defibrillator Use in Adult Congenital Heart Disease Patients
    Schefter, Zoe
    Walsh, Amy Z.
    Valente, Anne M.
    Alexander, Mark E.
    Dewitt, Elizabeth S.
    Bezzerides, Vassilios J.
    Triedman, John K.
    Mah, Douglas Y.
    CIRCULATION, 2019, 140