Development and validation of a sensitive, fast and simple LC-MS/MS method for the quantitation of favipiravir in human serum

被引:43
|
作者
Onmaz, Duygu Eryavuz [1 ]
Abusoglu, Sedat [1 ]
Onmaz, Mustafa [2 ]
Yerlikaya, Fatma Humeyra [1 ]
Unlu, Ali [1 ]
机构
[1] Selcuk Univ, Fac Med, Dept Biochem, Alaaddin Keykubat Campus, TR-42075 Selcuklu, Konya, Turkey
[2] Necmettin Erbakan Univ, Fac Med, Dept Family Med, Konya, Turkey
关键词
Favipiravir; COVID-19; Tandem mass spectrometry; Validation;
D O I
10.1016/j.jchromb.2021.122768
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Favipiravir is a broad-spectrum inhibitor of viral RNA polymerase. It is currently used as a possible treatment for coronavirus disease 2019 (COVID-19). Pre-clinical or clinical trials of favipiravir require robust, sensitive, and accurate bioanalytical methods for quantitation of favipiravir levels. Recently, several studies have been reported about developing a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring favipiravir levels. However, these methods were validated predominantly for plasma samples, electrospray ionization was operated only in negative or positive mode, and clinical application of these methods has not been applied for patients with COVID-19. This study aimed was to develop a validated LC-MS/MS method for the measurement of favipiravir levels in positive and negative electrospray ionization mode and to perform a pilot study in patients with COVID-19 receiving favipiravir to demonstrate the applicability of this method in biological samples. Simple protein precipitation was used for the extraction of favipiravir from the desired matrix. Favipiravir levels were quantitated using MS / MS with an electrospray ionization source in positive and negative multiple reaction monitoring (MRM) mode. The chromatographic detection was performed on a reverse-phase Phenomenex C18 column (50 mm x 4.6 mm, 5 mu m, 100 angstrom) with gradient elution using 0.1% formic acid in water and 0.1% formic acid in methanol as mobile phase. The method was linear over the concentration ranges of 0.048-50 mu g/mL (in negative ionization mode) and 0.062-50 mu g/mL (in positive ionization mode) with a correlation coefficient (r2) better than 0.998. The total run time was 3.5 min. The intra-assay and inter-assay % CV values were less than 7.2% and 8.0%, respectively. A simple, rapid and robust LC-MS / MS method was developed for the measurement of favipiravir and validation studies were performed. The validated method was successfully applied for drug level measurement in COVID-19 patients receiving favipiravir.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Fast and Sensitive LC-MS/MS Method for the Quantitation of Saponins in Various Sugar Beet Materials
    Edelmann, Matthias
    Dawid, Corinna
    Ralla, Theo
    Stark, Timo D.
    Salminen, Hanna
    Weiss, Jochen
    Hofmann, Thomas
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2020, 68 (50) : 15027 - 15035
  • [32] Validation of a novel LC-MS/MS method for the quantitation of colistin A and B in human plasma
    Dotsikas, Yannis
    Markopoulou, Catherine K.
    Koundourellis, John E.
    Loukas, Yannis L.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 37 - 45
  • [33] Ceftriaxone pharmacokinetics by a sensitive and simple LC-MS/MS method: Development and application
    Herrera-Hidalgo, L.
    Gil-Navarro, M., V
    Penchala, S. Dilly
    Lopez-Cortes, L. E.
    de Alarcon, A.
    Luque-Marquez, R.
    Lopez-Cortes, L. F.
    Gutierrez-Valencia, A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 189
  • [34] Fast and Simple LC-MS/MS Method for Rifampicin Quantification in Human Plasma
    Rakusa, Zane Temova
    Roskar, Robert
    Andrejc, Anita Klancar
    Lusin, Tina Trdan
    Faganeli, Natasa
    Grabnar, Iztok
    Mrhar, Ales
    Kristl, Albin
    Trontelj, Jurij
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [35] Development and validation of a sensitive LC-MS/MS method with electrospray ionization for quantitation of pramipexole in human plasma: application to a clinical pharmacokinetic study
    Bharathi, D. Vijaya
    Hotha, Kishore Kumar
    Sagar, P. V. Vidya
    Kumar, S. Sirish
    Naidu, A.
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (02) : 212 - 218
  • [36] Method development and validation of cabozantinib by LC-MS/MS
    Venkateshwarlu, Punna
    Patel, Mehul M.
    PHARMACIA, 2022, 69 (02) : 407 - 413
  • [37] Development and validation of a sensitive LC-MS/MS assay for simultaneous quantitation of ranolazine and its three metabolites in human plasma
    Wang, Yuan
    Chen, Xiaoyan
    Sun, Zuoming
    Yang, Yong
    Zhang, Ying
    Liu, Wanhui
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 889 : 10 - 16
  • [38] Development, validation and application of a sensitive LC-MS/MS method for the quantification of thalidomide in human serum, cells and cell culture medium
    Roche, Sandra
    Sewell, Louise
    Meiller, Justine
    Pedersen, Kasper
    Rajpal, Rajesh
    O'Gorman, Peter
    Clynes, Martin
    O'Connor, Robert
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 16 - 26
  • [39] Development and validation of a sensitive LC-MS/MS method for the determination of D-serine in human plasma
    Xie, Y.
    Alexander, G. M.
    Schwartzman, R. J.
    Singh, N.
    Torjman, M. C.
    Goldberg, M. E.
    Wainer, I. W.
    Moaddel, R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 1 - 5
  • [40] Development and validation of a sensitive LC-MS/MS method for the determination of fenoterol in human plasma and urine samples
    Sanghvi, M.
    Ramamoorthy, A.
    Strait, J.
    Wainer, I. W.
    Moaddel, R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 933 : 37 - 43