Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance

被引:3
|
作者
AL-Shareef, Jamal M. [1 ,2 ,3 ]
Attalla, Ehab M. [1 ]
El-Gebaly, Reem H. [2 ]
Deiab, Nashaat A. [1 ]
Abdelmajeed, M. [1 ]
Fathy, Mohamed M. [2 ]
机构
[1] Cairo Univ, Natl Canc Inst, Dept Radiotherapy & Nucl Med, Giza, Egypt
[2] Cairo Univ, Fac Sci, Dept Biophys, Giza, Egypt
[3] Sanaa Univ, Dept Phys, Sanaa, Yemen
关键词
In-vivo dosimetry; In-vitro dosimetry; Diode; IMRT; QA; EXIT DOSE MEASUREMENTS; MOSFET DETECTORS; ENTRANCE; ERRORS;
D O I
10.1016/j.radphyschem.2021.109564
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The implementation of an in-vivo diode for dose verification of the intensity-modulated radiotherapy (IMRT) during the actual treatment being rare. This work aims to implement in-vivo and in-vitro diode dosimetry for the IMRT technique to verify the accuracy of the dose delivered to the patients undergoing radiation treatment. In total, 279 fields have been investigated for dose verification from 33 cases, including head and neck, prostate, bladder, and breast cancer patients. Additionally, these fields were compared with in-vitro measurements on a perspex phantom. Beforehand, the measurements were tested for an Alderson Rando phantom. In-vivo measurements revealed that 87.1% of the measured doses were within +/- 5% of the calculated doses. Of the other 12.9%, about 11.1% were more than +/- 5% and less +/- 10% and only 1.8% were outside the +/- 10% of the calculated doses. The corresponding fields for in-vitro measurements show that 96.1% of the measured doses within +/- 5% and only 3.9% were outside the +/- 5% of the calculated doses. The results in this study indicated that in-vivo diode dosimetry for IMRT is reliable as a quality assurance (QA) tool in the radiotherapy departments. Moreover, measurements with diodes are a real-time readout during actual treatment compared to the verification tools that have been used for routine IMRT QA. Additionally, the measurements were carried out comfortably and well tolerated by the patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] In-vivo diode measurements as a tool for quality control of treatment dosimetry
    Shentall, G
    Fillingham, E
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S88 - S88
  • [22] Dosimetric validation of new semiconductor diode dosimetry system for intensity modulated radiotherapy
    Kinhikar, Rajesh
    Chaudhari, Suresh
    Kadam, Sudarshan
    Dhote, Dipak
    Deshpande, Deepak
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (01) : 86 - 90
  • [23] Dosimetry of gated intensity modulated radiotherapy
    Solberg, TD
    Paul, TJ
    Agazaryan, NN
    Urmanita, T
    Arellano, AR
    Llacer, J
    Boone, RA
    Fog, R
    DeMarco, JJ
    Chetty, I
    Smathers, JB
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 286 - 288
  • [24] In-vivo quality assurance
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S55 - S56
  • [25] In-vivo diode Dosimetry for IMRT fields
    Circiumaru, O.
    Zhu, T.
    MEDICAL PHYSICS, 2006, 33 (06) : 2111 - 2111
  • [26] Testing of Prototype Delta4AT Diode Array for In-Vivo Radiotherapy Dosimetry
    Riley, S.
    Matzen, T.
    Carver, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Film dosimetry for quality assurance of an intensity modulated arc therapy (IMAT) treatment
    Bakai, A
    Duthoy, W
    De Gersem, W
    Gillis, S
    De Wagter, C
    De Neve, W
    Nüsslin, F
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 65 - 65
  • [28] Multichannel Film Dosimetry for Quality Assurance of Intensity Modulated Radiotherapy Treatment Plans Under 0.35 T Magnetic Field
    Gungor, Gorkem
    Korkmaz, Latif
    Kayalilar, Namik
    Aydin, Gokhan
    Yapici, Bulent
    Mustafayev, Teuta Zoto
    Atalar, Banu
    Ozyar, Enis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (03)
  • [29] Quality Assurance of Nasopharyngeal Carcinoma Intensity Modulated Radiotherapy Treatment Plans Using Three Dimensional Dosimetry Verification System
    Ma, C.
    Yin, Y.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S321 - S321
  • [30] Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry
    Vinall, A. J.
    Williams, A. J.
    Currie, V. E.
    Van Esch, A.
    Huyskens, D.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (995): : 949 - 957