Peritoneal Catheter Fixation to the Abdominal Wall in Surgical Catheter Implantation to Prevent Malfunction

被引:7
|
作者
Wang, Huiming [1 ]
Jia, Houjun [2 ]
Lv, Xifeng [1 ]
Ding, Guohua [1 ]
机构
[1] Wuhan Univ, Renmin Hosp, Renal Dept, Wuhan 430060, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Dept Gen Surg, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Peritoneal dialysis; Catheter malposition; Chronic renal failure; DIALYSIS CATHETER; PLACEMENT; INSERTION; PD;
D O I
10.1159/000368214
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Catheter failure, especially catheter displacement and obstruction remain the major barriers for peritoneal dialysis. We have developed a new surgery technique of catheter fixation on the lower abdominal wall in the catheter planting to avert the catheter mechanical complications. Method: A retrospective study was performed on 93 patients; among them, 52 patients underwent the traditional method of surgery for catheter insertion and 41 patients received additional catheter fixation. Comparisons of complications including infection, leak, infusion pains, catheter displacement, and obstruction occurred during a follow-up period of 6 months, were made between the fixed and non-fixed groups. Results: Catheter fixation cost more time than the conventional operating procedure (94.2 +/- 14.6 min vs. 83 +/- 13.3 min, p = 0.043). Complications of infection, leak, and infusion pain that occurred in the fixed and unfixed groups are comparable. Catheter fixation reduced the complications of catheter displacement or obstruction to 0 episode in the fixed group, whereas those complications were encountered by 7 patients in the unfixed group (0/41 vs. 7/52, p = 0.0 22). All these 7 patients received re-exploration and catheter replacement with further catheter fixation. In the following time until now (ranging from 3 to 16 months), no catheter dysfunction was observed. Conclusions: These results suggest that catheter fixation is effective in preventing catheter displacement and obstruction in peritoneal dialysis. (C) 2014 S. Karger AG, Basel
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [21] Laparoscopic-Assisted Abdominal Wall Pexy of Peritoneal Dialysis Catheter
    Wei, Wei
    Fanous, Medhat
    AMERICAN SURGEON, 2021, 87 (01) : 131 - 133
  • [22] Catheter implantation and the treatment of catheter exit spot in peritoneal dialysis
    Krauth, H
    DIALYSE 1995, 1996, : 55 - 62
  • [23] A MODIFIED OPEN SURGERY TECHNIQUE FOR PERITONEAL DIALYSIS CATHETER PLACEMENT DECREASES CATHETER MALFUNCTION
    Jiang, Chunming
    Xu, Linfeng
    Chen, Yun
    Yan, Xiang
    Sun, Cheng
    Zhang, Miao
    PERITONEAL DIALYSIS INTERNATIONAL, 2014, 34 (04): : 358 - 367
  • [24] Peritoneal dialysis catheter malfunction caused by wrapping of the catheter by the sigmoid mesocolon: a case report
    Shao, Xiao-Jiao
    Zhang, Li Yuan
    RENAL FAILURE, 2021, 43 (01) : 313 - 314
  • [25] Modified laparoscopic placement of peritoneal dialysis catheter with intra-abdominal fixation
    Quanquan Shen
    Xinxin Jiang
    Xiaogang Shen
    Fangyan Yu
    Qiudi Tu
    Wangfang Chen
    Qing Ye
    Tapas Ranjan Behera
    Qiang He
    International Urology and Nephrology, 2017, 49 : 1481 - 1488
  • [26] Resuming automated peritoneal dialysis after laparoscopic peritoneal wall anchoring for peritoneal dialysis catheter fixation
    Matsunami, Masatoshi
    Suzuki, Tomo
    Suzuki, Koichiro
    Kuji, Hiroshi
    JOURNAL OF NEPHROLOGY, 2024, 37 (04) : 1051 - 1061
  • [27] Modified laparoscopic placement of peritoneal dialysis catheter with intra-abdominal fixation
    Shen, Quanquan
    Jiang, Xinxin
    Shen, Xiaogang
    Yu, Fangyan
    Tu, Qiudi
    Chen, Wangfang
    Ye, Qing
    Behera, Tapas Ranjan
    He, Qiang
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2017, 49 (08) : 1481 - 1488
  • [28] Percutaneous peritoneal dialysis catheter implantation
    Soler, Laura Boix, I
    Suarez, Gabriel Manuel Gonzalez
    Devia, Claudia Marcela Castillo
    Saltos, Jehimy Jean Alvarez
    Cantalejo, Leyre Garcia
    Alemany, Nadia Martin
    Martinez, Jordi Calabia
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [29] Percutaneous peritoneal dialysis catheter implantation
    I. Soler, Laura Boix
    Gonzalez Suarez, Gabriel Manuel
    Castillo Devia, Claudia Marcela
    Alvarez Saltos, Jehimy Jean
    Garcia Cantalejo, Leyre
    Martin Alemany, Nadia
    Calabia Martinez, Jordi
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I2610 - I2611
  • [30] Cerebrospinal Fluid Drainage System Peritoneal Catheter Malfunction in Children
    Brichtova, E.
    Mackerle, Z.
    Tuma, J.
    Gal, P.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2009, 72 (05) : 461 - 465