Enhancement of a 252Cf-based neutron beam via subcritical multiplication for neutron capture therapy

被引:0
|
作者
Wang, CK [1 ]
Zino, JF [1 ]
Kessler, G [1 ]
机构
[1] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
关键词
Monte Carlo; neutron capture therapy; subcritical multiplication; Cf-252;
D O I
10.1016/S0969-8043(00)00237-2
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Previous studies indicated that an epithermal-neutron beam based on bare Cf-252 is not feasible for neutron capture therapy (NCT). It was reported that a clinically useful epithermal-neutron beam requires a minimum of 1.0 g of Cf-252, which is more than twice the US current annual supply. However, it was reasoned that the required quantity of Cf-252 could be dramatically reduced when used with a subcritical multiplying assembly (SMA), This reasoning is based on the assumption that the epithermal-neutron beam intensity for NCT is directly proportional to the fission neutron population, and that the neutron multiplying factor of the SMA can be estimated by 1/(1 - k(eff)). We have performed detailed Monte Carlo calculations to investigate the validity of the above reasoning. Our results show that 1/(1 - k(eff)) grossly overestimates the beam enhancement factor for NCT. For example, Monte Carlo calculations predict a beam enhancement factor of 6.0 for an optimized SMA geometry with k(eff) = 0.968. This factor is much less than 31 predicted by 1/(1 - k(eff)). The overestimation is due to the fact that most of the neutrons produced in the SMA are self-shielded, whereas self-shielding is negligible in a bare Cf-252 source. Since the beam intensity of a 0.1 g Cf-252 With the optimized SMA enhancement is still more than an order of magnitude too low compared to the existing reactor beams, we conclude that the enhancement via an SMA for a Cf-252-based epithermal-neutron beam is inadequate for NCT. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:811 / 814
页数:4
相关论文
共 50 条
  • [31] Electronic imaging for Cf-252 based neutron radiography
    Mochiki, K
    Akaike, H
    Murata, Y
    Moki, T
    Ishikawa, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 137 - 139
  • [32] Microdosimetric spectra of the THOR neutron beam for boron neutron capture therapy
    Hsu, FY
    Tung, CJ
    Watt, DE
    RADIATION PROTECTION DOSIMETRY, 2003, 104 (02) : 121 - 126
  • [33] Status of epithermal neutron beam design for neutron capture therapy at THOR
    Liu, YWH
    Chu, HJ
    Liu, HM
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A363 - A366
  • [34] DU PONT BNL INVESTIGATE 252CF FOR NEUTRON THERAPY
    不详
    CHEMICAL & ENGINEERING NEWS, 1968, 46 (41) : 54 - &
  • [35] A modified fast neutron therapy beam for boron neutron capture enhanced fast neutron therapy (BNCEFNT)
    Kota, C
    Maughan, RL
    Burmeister, J
    Forman, JD
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A496 - A500
  • [36] INTERSTITIAL NEUTRON THERAPY FOR MALIGNANT GLIOMAS USING CF-252
    MARUYAMA, Y
    YOUNG, AB
    CHIN, HW
    BEACH, JL
    MARKESBERY, W
    JOURNAL OF NEURO-ONCOLOGY, 1984, 2 (03) : 283 - 283
  • [37] Cf252 interstitional neutron therapy of malignant tumours of vagina
    Spikalovas, V
    Valuckas, K
    Atkocius, V
    EUROPEAN JOURNAL OF CANCER, 1995, 31A : 186 - 186
  • [38] INTERSTITIAL CF-252 NEUTRON THERAPY FOR GLIOBLASTOMA-MULTIFORME
    MARUYAMA, Y
    CHIN, HW
    YOUNG, AB
    BEAN, J
    TIBBS, P
    BEACH, JL
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1982, 5 (06): : 589 - 591
  • [39] Accelerator based neutron source for neutron capture therapy
    Belchenko, Y
    Dimov, G
    Kononov, V
    Kononov, O
    Kuksanov, N
    Kraynov, G
    Salimov, R
    Silvestrov, G
    Shirokov, V
    Skrinsky, A
    Smirnov, G
    Sysoev, A
    Taskaev, S
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 293 - 297
  • [40] Neutronic design of a fission converter-based epithermal neutron beam for neutron capture therapy
    Kiger, WS
    Sakamoto, S
    Harling, OK
    NUCLEAR SCIENCE AND ENGINEERING, 1999, 131 (01) : 1 - 22