Rapid detection of microbial contamination in Triclosan and High Fluoride Dentifrices using an ATP Bioluminescence assay

被引:11
|
作者
Ignar, R [1 ]
English, D [1 ]
Jimenez, L [1 ]
机构
[1] Block Drug Co, Res & Dev Microbiol Lab, Jersey City, NJ 07302 USA
关键词
D O I
10.1111/j.1745-4581.1998.tb00183.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The Celsis A TP Bioluminescence method was optimized and validated to detect the presence of microbial contamination in High Fluoride and Triclosan dentifrice formulations. Several enrichment broths were evaluated by using a 24-27 h incubation period. The A TP concentrations of the enrichment broths were found to a range from 0.012 to 0.040 nM. None of the tested enrichment broths were found to exhibit any sample inhibition/enhancement effects on the ATP Bioluminescence reaction. Dentifrice suspensions were inoculated with bacteria, yeast, and mold. All test microorganisms (ca. 1-15 CFU/g) were detected within a 24-27 h incubation period by using TAT Broth Base enrichment broths containing different concentrations of the following ingredients: Tween 20, Neopeptone, Dextrose, Triton X-100, Thiosulfate, Sodium Dibasic Phosphate, and Glycine. Negative ATP response after 24-27 h of incubation at 35C indicates the absence of contamination from these products.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [21] Assessment of contamination using an ATP bioluminescence assay on doorknobs in a university-affiliated hospital in Japan
    Kajigaya N.
    Hirose Y.
    Koike S.
    Fujita T.
    Yokota N.
    Hata S.
    Ikenaga M.
    Kobayashi N.
    Takahashi T.
    BMC Research Notes, 8 (1)
  • [22] RAPID METHODS FOR THE DETECTION OF YEAST AND LACTOBACILLUS BY ATP BIOLUMINESCENCE
    MILLER, R
    GALSTON, G
    JOURNAL OF THE INSTITUTE OF BREWING, 1989, 95 (05) : 317 - 319
  • [23] Using ATP driven bioluminescence assay to monitor microbial safety in a contemporary human cadaver lab
    Benninger, Brion
    Maier, Thomas
    FASEB JOURNAL, 2008, 22
  • [24] Rapid Detection of Microbial Contamination in Intravenous Fluids by ATP-Based Monitoring System
    Oie, Shigeharu
    Kamiya, Akira
    Yamasaki, Hirofumi
    Kouda, Kyoji
    Furukawa, Hiroyuki
    Tsuruta, Ryosuke
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2020, 73 (05) : 363 - 365
  • [25] An ATP bioluminescence assay applicable to rapid fluconazole susceptibility testing of dermatophytes
    Yoshida, T
    Uchida, K
    Yamaguchi, H
    MICROBIOLOGY AND IMMUNOLOGY, 1997, 41 (05) : 377 - 386
  • [26] On-chip bioluminescence biosensor for the detection of microbial surface contamination
    Abbasi, Reza
    Imanbekova, Meruyert
    Wachsmann-Hogiu, Sebastian
    BIOSENSORS & BIOELECTRONICS, 2024, 254
  • [27] High sensitivity detection of ATP using bioluminescence at an optical fiber end
    Hiroshima University, ADSM, Department of Quantum Matter, 1-3-1 Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8530, Japan
    不详
    不详
    不详
    IEEJ Trans. Electron. Inf. Syst., 2007, 10 (1498-1503+1):
  • [28] Wastewater and sludge: The rapid determination of microbial content by ATP bioluminescence.
    Girotti, S
    Zanetti, F
    Ferri, E
    Stampi, S
    Fini, F
    Righetti, S
    Roda, A
    Budini, R
    ANNALI DI CHIMICA, 1998, 88 (3-4) : 291 - 298
  • [29] On-chip bioluminescence biosensor for the detection of microbial surface contamination
    Abbasi, Reza
    Imanbekova, Meruyert
    Wachsmann-Hogiu, Sebastian
    Biosensors and Bioelectronics, 2024, 254
  • [30] Rapid Detection of Microbial Count Using Portable Bioluminescence-based Biosensor
    Luo Jin-Ping
    Tian Qing
    Yue Wei-Wei
    He Bao-Shan
    Cai Xin-Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (02) : 306 - 310