Long-term monitoring of hazardous volatile organic air pollutants using capillary GC-MS

被引:0
|
作者
Maeda, T
Tanabe, K
Morita, M
机构
[1] DKK Corp, Appl R&D Div, Musashino, Tokyo 180, Japan
[2] Natl Inst Environm Studies, Tsukuba, Ibaraki 305, Japan
来源
LC GC-MAGAZINE OF SEPARATION SCIENCE | 1998年 / 16卷 / 05期
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors investigated a continuous monitoring method for volatile organic air pollutants based on gas chromatography-mass spectrometry with an automatic sample collection system. The collection system comprised two stainless steel canisters and an automatic sample introduction system with a microtrap. The canisters collected sample by turns and provided an average sampling interval, which enabled long-term continuous monitoring with a reasonable number of measurements.
引用
收藏
页码:478 / +
页数:5
相关论文
共 50 条
  • [1] GC x GC-MS HYPHENATED TECHNIQUES FOR THE ANALYSIS OF VOLATILE ORGANIC COMPOUNDS IN AIR
    Arsene, Cecilia
    Vione, Davide
    Grinberg, Nelu
    Olariu, Romeo Iulian
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (13) : 1077 - 1111
  • [2] WCOT CAPILLARY COLUMN GC-FT-IR AND GC-MS FOR IDENTIFYING TOXIC ORGANIC POLLUTANTS
    SHAFER, KH
    COOKE, M
    DEROOS, F
    JAKOBSEN, RJ
    ROSARIO, O
    MULIK, JD
    APPLIED SPECTROSCOPY, 1981, 35 (05) : 469 - 472
  • [3] Development and application of GC-MS method for monitoring of long-term exposure to the pesticide cypermethrin
    Kavvalakis, Matthaios P.
    Tzatzarakis, Manolis N.
    Alegakis, Athanasios K.
    Vynias, Dionysios
    Tsakalof, Andreas K.
    Tsatsakis, Aristidis M.
    DRUG TESTING AND ANALYSIS, 2014, 6 : 9 - 16
  • [4] CAPILLARY COLUMNS IN SERIES FOR GC ANALYSIS OF VOLATILE ORGANIC POLLUTANTS IN ATMOSPHERIC AND ALVEOLAR AIR
    CLAIR, P
    TUA, M
    SIMIAN, H
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (06): : 383 - 387
  • [5] DETERMINATION OF VOLATILE POLLUTANTS IN HUMAN AND ANIMAL MILK BY GC-MS
    KRONELD, R
    REUNANEN, M
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1990, 44 (06) : 917 - 923
  • [6] Spatial and long-term temporal assessment of organic hazardous air pollutants and their comparative health risks
    Kim, K. H.
    Chun, H. -H.
    Jo, W. K.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2015, 12 (12) : 3929 - 3942
  • [7] Spatial and long-term temporal assessment of organic hazardous air pollutants and their comparative health risks
    K. H. Kim
    H.-H. Chun
    W. K. Jo
    International Journal of Environmental Science and Technology, 2015, 12 : 3929 - 3942
  • [8] Analysis of wastewater for volatile (purgeable) organic by GC-MS
    Butler, Jessie
    Steiniger, David
    Phillips, Eric
    LC GC EUROPE, 2008, : 10 - 10
  • [9] Ultrasonic assisted SPME coupled with GC and GC-MS using pencil lead as a fiber for monitoring the organic volatile impurities of ceftazidime
    Djozan, Djavanshir
    Jouyban, Abolghasem
    Norouzi, Jamal
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (08) : 680 - 685
  • [10] Volatile Organic Compound Profiling Using GC-MS to Characterize Patients with Bronchiectasis
    Gu, S.
    Xu, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201