Dual range lactate oxidase-based screen printed amperometric biosensor for analysis of lactate in diversified samples

被引:37
|
作者
Cunha-Silva, Hugo [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Chem, Plaza Misael Banuelos S-N, Burgos 09001, Spain
关键词
Lactate oxidase; Dual range biosensor; Noninvasive analysis; Sweat; Saliva; Wine; METAL-ORGANIC FRAMEWORKS; LACTIC-ACID; PLATINUM-ELECTRODES; HYDROGEN-PEROXIDE; ELECTROCHEMICAL OXIDATION; BIENZYMATIC BIOSENSOR; EXERCISE INTENSITY; HUMAN PERSPIRATION; GLUCOSE-OXIDASE; CHITOSAN BEADS;
D O I
10.1016/j.talanta.2018.06.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lactate concentration is studied as an indicator of physical performance in sports activities, and is also analyzed in health care applications, as well as in the food and cosmetic industries. This organic acid is routinely determined in different concentration ranges, depending on the type of samples for analysis. This paper describes the development of a screen-printed lactate oxidase (LOx) based biosensor to determine lactate in broad concentration range. The Cu-MOF (copper metallic framework) crosslinking of 0.25U LOx in a chitosan layer, allows to determine the enzymatic product generated on a platinum modified working electrode, at 0.15 V (vs SPE Ag/AgCl). The biosensor responds linearly in two different concentration ranges: a first catalysis range of 14.65 mu A mM(-1), from 0.75 mu M to 1 mM, followed by a saturation zone from 1 to 4 mM, after which a substrate enzymatic inhibition of 0.207 mu A mM(-1), is observed up to 50 mM. These two ranges of analysis would allow the biosensor to be used for the determination of lactate in different types of samples, with low and high content of lactate. The method reproducibility was kept below 7% and a limit of detection of 0.75 mu M was obtained. The device was successfully used in the determination of lactate in sweat and saliva, as a low cost noninvasive analysis, and also in wine samples.
引用
收藏
页码:779 / 787
页数:9
相关论文
共 50 条
  • [21] Lactate biosensor based on the adsorption of polyelectrolyte stabilized lactate oxidase into porous conductive carbon
    Gavalas, VG
    Chaniotakis, NA
    MIKROCHIMICA ACTA, 2001, 136 (3-4) : 211 - 215
  • [22] Design and characterization of a lactate biosensor based on immobilized lactate oxidase onto gold surfaces
    Parra, A
    Casero, E
    Vázquez, L
    Pariente, F
    Lorenzo, E
    ANALYTICA CHIMICA ACTA, 2006, 555 (02) : 308 - 315
  • [23] Lactate Biosensor Based on the Adsorption of Polyelectrolyte Stabilized Lactate Oxidase into Porous Conductive Carbon
    Vasilis G. Gavalas
    Nikolas A. Chaniotakis
    Microchimica Acta, 2001, 136 : 211 - 215
  • [24] Dual Biosensor for Simultaneous Monitoring of Lactate and Glucose Based on Thin-layer Flow Cell Screen-printed Electrode
    Kanso, Hussein
    Gonzalez Garcia, Maria Begona
    Ma, Su
    Ludwig, Roland
    Fanjul Bolado, Pablo
    Hernandez Santos, David
    ELECTROANALYSIS, 2017, 29 (01) : 87 - 92
  • [25] AMPEROMETRIC L-LACTATE-SENSING ELECTRODE BASED ON A POLYION COMPLEX LAYER CONTAINING LACTATE OXIDASE - APPLICATION TO SERUM AND MILK SAMPLES
    MIZUTANI, F
    YABUKI, S
    HIRATA, Y
    ANALYTICA CHIMICA ACTA, 1995, 314 (03) : 233 - 239
  • [26] Biosensor Based on Peroxidase-Mimetic Nanozyme and Lactate Oxidase for Accurate L-Lactate Analysis in Beverages
    Smutok, Oleh
    Kavetskyy, Taras
    Prokopiv, Tetiana
    Serkiz, Roman
    Sausa, Ondrej
    Novak, Ivan
    Svajdlenkova, Helena
    Mat'ko, Igor
    Gonchar, Mykhailo
    Katz, Evgeny
    BIOSENSORS-BASEL, 2022, 12 (11):
  • [27] Continuous sweat lactate monitoring system with integrated screen-printed Mgo-templated carbon-lactate oxidase biosensor and microfluidic sweat collector
    Shitanda, Isao
    Mitsumoto, Masaya
    Loew, Noya
    Yoshihara, Yuko
    Watanabe, Hikari
    Mikawa, Tsutomu
    Tsujimura, Seiya
    Itagaki, Masayuki
    Motosuke, Masahiro
    ELECTROCHIMICA ACTA, 2021, 368 (368)
  • [28] AN IN-SITU ELECTROSYNTHESIZED AMPEROMETRIC BIOSENSOR BASED ON LACTATE OXIDASE IMMOBILIZED IN A POLY-O-PHENYLENEDIAMINE FILM - DETERMINATION OF LACTATE IN SERUM BY FLOW-INJECTION ANALYSIS
    PALMISANO, F
    CENTONZE, D
    ZAMBONIN, PG
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (07): : 471 - 479
  • [29] A screen-printed, amperometric biosensor for the determination of organophosphorus pesticides in water samples
    Raju Sekar
    Journal of Environmental Sciences, 2012, 24 (05) : 956 - 962
  • [30] A screen-printed, amperometric biosensor for the determination of organophosphorus pesticides in water samples
    Dou, Junfeng
    Fan, Fuqiang
    Ding, Aizhong
    Cheng, Lirong
    Sekar, Raju
    Wang, Hongting
    Li, Shuairan
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2012, 24 (05) : 956 - 962