power system measurement; support vector machines; electric generators; power system simulation; power system security; least squares approximations; power system transient stability; power system control; learning (artificial intelligence); rotors; transient stability-oriented assessment; preventive control action; deregulated power system; modern power system; increasing penetration; renewable resources; system capacity; deregulated scenario; system reliability; security; system operator; severe contingencies; system operating constraints; real-time transient stability assessment; phasor measurement units; square support vector machine; system stability state; coherency-based selection method; generation rescheduling; preventive operation; insecure operating contingency; rotor angle trajectories-based transient severity index; critical generators; noncritical generators; system transient stability; power network; supervised learning approach preventive control; 39-bus system; complex power system models;
D O I
10.1049/joe.2018.9353
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The modern power system is becoming more complex and dynamic because of increasing penetration of renewable energy resources, operating closer to system capacity for economic benefits. In order to maintain the system stability, the system operator is required to initiate appropriate preventive control action under severe contingencies while satisfying the system operating constraints. Real time transient stability assessment (TSA) of power system is proposed in this paper by using wide area measurement system (WAMS) and phasor measurement units (PMUs). An architecture based on least square support vector machine (LS-SVM) has been developed to identify the system stability state in real time. Also, this paper proposes a coherency based selection method to identify the appropriate members for generation rescheduling as preventive operation in insecure operating contingency. Rotor angle trajectories based transient stability index (TSI) is employed to classify the generators as either critical or non-critical generators in a power network. Accordingly preventive control action in the form of generation rescheduling can be initiated to achieve stability. The method has been demonstrated on the IEEE 10-machines, 39-bus system. The proposed methodology is effective and capable of handling complex power system models with multiple contingencies.
引用
收藏
页码:5345 / 5350
页数:6
相关论文
共 50 条
  • [41] ELM Model for Power System Transient Stability Assessment
    Zhang Linlin
    Hu Xiongwei
    Li Peng
    Shi Fang
    Yu Zhihong
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 5740 - 5744
  • [42] Transient Stability Assessment of Power System Using ELM
    Zhang, Shang
    ELECTRONIC INFORMATION AND ELECTRICAL ENGINEERING, 2012, 19 : 901 - 903
  • [43] A Review of Power System Transient Stability Analysis and Assessment
    Wang, Huimin
    Li, Zhaojun
    2019 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-QINGDAO), 2019,
  • [44] Truncated Transient Stability Index for On-line Power System Transient Stability Assessment
    Ye, Xinlin
    Morales, Juan D.
    Milanovic, Jovica, V
    2021 IEEE PES INNOVATIVE SMART GRID TECHNOLOGY EUROPE (ISGT EUROPE 2021), 2021, : 266 - 270
  • [45] Stability-oriented Line Impedance Domain Assessment for Weak Grids With Constant Power Loads: An Impedance-based Approach
    Wang R.
    Sun Q.
    Qin D.
    Hu W.
    Ma D.
    Li X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (04): : 1284 - 1294
  • [46] Transient Stability Assessment and Emergency Control Strategy Based on Random Forest in Power System
    Wang T.
    Liu J.
    Zhu S.
    Wang Z.
    Qin H.
    Zhang Y.
    Zhang X.
    Wang, Tong (hdwangtong@126.com), 1600, Power System Technology Press (44): : 4694 - 4701
  • [47] A coherency based generator rescheduling for preventive control of transient stability in power systems
    Verma, Kusum
    Niazi, K. R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 45 (01) : 10 - 18
  • [48] Distributed FACTS for Power System Transient Stability Control
    Bruno, Sergio
    De Carne, Giovanni
    La Scala, Massimo
    ENERGIES, 2020, 13 (11)
  • [49] Analytic Deep Learning and Stepwise Integrated Gradients-Based Power System Transient Stability Preventive Control
    Liu, Youbo
    Su, Tong
    Qiu, Gao
    Gao, Hongjun
    Liu, Junyong
    Shui, Yue
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (01) : 863 - 876
  • [50] An integrated scheme to coordinate preventive control and emergency control for transient stability enhancement in power systems
    Yang, XL
    Sun, YZ
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 329 - 332