Evaluation of Gianturco coils for closure of large (>=3.5 mm) patent ductus arteriosus

被引:44
|
作者
Owada, CY
Teitel, DF
Moore, P
机构
[1] Division of Pediatric Cardiology, Univ. of California San Francisco, San Francisco, CA
[2] Division of Pediatric Cardiology, Box 0544, Univ. of California at San Francisco, San Francisco, CA 94143
关键词
D O I
10.1016/S0735-1097(97)00382-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This report evaluates the use of Gianturco coils to close large patent ductus arteriosus (PDAs) (greater than or equal to 3.5 mm) and describes transvenous delivery of 0.052-in. (0.132-cm) Gianturco coils. Background. Coil closure of PDAs has become increasingly popular, However, the technique has significant limitations when used to close large PDAs. This report evaluates patient characteristics, PDA anatomy, hemodynamic variables, delivery technique and coil geometry to determine predictors of success. Methods. Between January 1995 and January 1997, 16 of 118 patients undergoing catheterization for PDA closure were found to have large PDAs. Their median age and weight were 14 months (range 3 months to 43 years) and 8.5 kg (range 3.5 to 73), respectively, The mean PDA diameter was 4.3 mm (range 3.5 to 5.9), Closure of PDAs was attempted using transcatheter delivery of 0.038-in. (0.096-cm) and 0.052-in. coils. Differences in clinical, anatomic, hemodynamic and technical variables between successes and failures were compared. Results. Eleven (69%) of 16 patients had successful closure of their PDA, Failures occurred only in patients <8 months of age with an indexed PDA diameter >7 mm/m and a pulmonary/systemic how ratio greater than or equal to 2.8:1. Use of 0.052-in. coils tended to reduce the incidence of embolization and the number of coils needed for closure, Conclusions. Patients >8 months of age can have successful closure of large PDAs with currently available Gianturco coils, The 0.052-in. Gianturco coils can be used safely to close large PDAs in infants as small as 6 kg. Increased experience and improved coil design may improve closure rates of large PDAs in infants. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:1856 / 1862
页数:7
相关论文
共 50 条
  • [31] Transarterial occlusion of patent ductus arteriosus with Gianturco coils in pediatric patients: a preliminary result in central Taiwan
    Lee, ML
    Chaou, WT
    Wang, JK
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (01) : 57 - 63
  • [32] Transcatheter closure of patent ductus arteriosus using coils and Amplatzer duct occluder
    Dai, Z
    Zhang, Y
    Wang, H
    Jia, G
    Wang, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 164L - 165L
  • [33] Influence of ductal size on the results of transcatheter closure of patent ductus arteriosus with coils
    Fu, YC
    Hwang, B
    Jan, SL
    Lee, BC
    Ting, CT
    Chen, YT
    Chi, CS
    JAPANESE HEART JOURNAL, 2003, 44 (03): : 395 - 401
  • [34] Closure of patent ductus arteriosus with detachable coils: Easy is better than hard
    Hoyer, MH
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 43 (04): : 492 - 492
  • [35] IS TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS USING MULTIPLE COILS FEASIBLE
    INO, T
    NISHIMOTO, K
    AKIMOTO, K
    OHKUBO, M
    YABUTA, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08): : 637 - 637
  • [36] Percutaneous closure of patent ductus arteriosus using special screwing detachable coils
    Podnar, T
    Masura, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 41 (04): : 386 - 391
  • [37] Transcatheter coil closure of large patent ductus arteriosus with 0.052-inch Gianturco coils using myocardial biopsy forceps in a 70-year-old woman
    Tokuda Y.
    Matsumoto M.
    Suda K.
    Matsumura M.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2001, 49 (6): : 381 - 383
  • [38] Percutaneous closure of large patent ductus arteriosus in adult patients
    Hernandez, F.
    Garcia-Tejada, J.
    Velazquez, M. T.
    Gomez, I.
    Bastante, T.
    Unzue, L.
    Gonzalez, A.
    De Riva, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 393 - 393
  • [39] Transcatheter closure with single or multiple Gianturco coils of patent ductus arteriosus in infants weighing <=8kg: Retrograde versus antegrade approach
    Hijazi, ZM
    Lloyd, TR
    Beekman, RH
    Geggel, RL
    AMERICAN HEART JOURNAL, 1996, 132 (04) : 827 - 835
  • [40] TRANSCATHETER CLOSURE OF PATENT DUCTUS ARTERIOSUS
    高伟
    周爱卿
    余志庆
    李奋
    王荣发
    黄美蓉
    Journal of Shanghai Second Medical University, 2002, (01) : 47 - 49