Enhancing the performance of a single-basin single-slope solar still by using Fresnel lens: Experimental study
被引:62
|
作者:
Mu, Lei
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Mu, Lei
[1
]
Xu, Xuesong
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Civil Engn, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Xu, Xuesong
[2
]
Williams, Thomas
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Williams, Thomas
[1
]
Debroux, Claire
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Debroux, Claire
[1
]
Gomez, Rocio Castillo
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Gomez, Rocio Castillo
[1
]
Park, Young Ho
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Park, Young Ho
[1
]
Wang, Huiyao
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Civil Engn, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Wang, Huiyao
[2
]
Kota, Krishna
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Kota, Krishna
[1
]
Xu, Pei
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Civil Engn, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Xu, Pei
[2
]
Kuravi, Sarada
论文数: 0引用数: 0
h-index: 0
机构:
New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USANew Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
Kuravi, Sarada
[1
]
机构:
[1] New Mexico State Univ, Dept Mech & Aerosp Engn, 1040 S Horseshoe St, Las Cruces, NM 88003 USA
[2] New Mexico State Univ, Dept Civil Engn, Las Cruces, NM 88003 USA
Solar still;
Solar energy;
Desalination;
Fresnel lens;
Experimental study;
Water productivity enhancement;
BOILING HEAT-TRANSFER;
PHASE-CHANGE MATERIAL;
THERMAL PERFORMANCE;
DESALINATION SYSTEM;
WATER;
ENHANCEMENT;
STORAGE;
NANOPARTICLES;
ABSORBER;
ENERGY;
D O I:
10.1016/j.jclepro.2019.118094
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
A refraction-based methodology for concentrating sunlight is proposed to augment the pure water production of a conventional solar still. The Fresnel lens (FRL) was integrated with a single-basin, single-slope solar still to refract the incident sunlight to a focal point that was constantly located on the basin bottom. Due to the introduction of the FRL, two major impressive findings were observed. The first observation was a high hourly productivity window (HHPW), during which the proposed system produced fresh water at a relatively high and stable rate. The second one was the occurrence of nucleate boiling phenomenon, which is believed to significantly increase the heat transfer coefficient for the phase change process of the basin water. Consequently, with the increased heat input and the high heat transfer rate, the utilization of FRL achieved a significant pure water production enhancement (L/m(2)/day) of about 467%, as well as a significant daily efficiency (eta) improvement of about 84.7%, compared to a conventional system without FRL. A series of tests were conducted to study the impact of the operational parameters on the system performance. The system daily output demonstrated a linear and negative correlation with water depth (d(w)) in the basin. The introduction of forced air cooling showed a positive impact on system performance and enhanced the distillate yield. It was also found that increasing d(w) or/and applying forced air cooling effect could benefit from increasing eta. (C) 2019 Elsevier Ltd. All rights reserved.
机构:
Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, IranChandigarh Univ, Dept Mech Engn, Mohali 140413, Punjab, India
Khalilpoor, Nima
Sharifpur, Mohsen
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pretoria, Dept Mech & Aeronaut Engn, Clean Energy Res Grp, Pretoria, South Africa
China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung, TaiwanChandigarh Univ, Dept Mech Engn, Mohali 140413, Punjab, India
机构:
Univ Strathclyde, Dept Mech Engn, Energy Syst Res Unit, Glasgow G1 1XJ, Lanark, ScotlandUniv Strathclyde, Dept Mech Engn, Energy Syst Res Unit, Glasgow G1 1XJ, Lanark, Scotland
Madhlopa, A.
Johnstone, C.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Strathclyde, Dept Mech Engn, Energy Syst Res Unit, Glasgow G1 1XJ, Lanark, ScotlandUniv Strathclyde, Dept Mech Engn, Energy Syst Res Unit, Glasgow G1 1XJ, Lanark, Scotland
机构:
Anna Univ, Univ Coll Engn Villupuram, Dept Mech Engn, Chennai 605103, Tamil Nadu, IndiaAnna Univ, Univ Coll Engn Villupuram, Dept Mech Engn, Chennai 605103, Tamil Nadu, India