Mass-transfer efficiency of a spray column for CO2 capture by MEA

被引:65
|
作者
Kuntz, Jeffery [1 ]
Aroonwilas, Adisorn [1 ]
机构
[1] Univ Regina, Fac Engn, Regina, SK S4S 0A2, Canada
来源
关键词
CO2; capture; absorption; spray column; mass transfer coefficient; mass transfer area; alkanolamine; ABSORPTION PERFORMANCE; STRUCTURED PACKINGS; PACKED-COLUMN; CONTACTORS;
D O I
10.1016/j.egypro.2009.01.029
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A parametric study of carbon dioxide (CO2) absorption performance into an aqueous solution of monoethanolamine (MEA) in the spray column was carried out experimentally over wide ranges of process conditions. The performance of the spray was interpreted in terms of the overall mass transfer coefficient (K(G)a(e)) and was found to vary with process parameters, including gas flow rate, liquid flow rate, CO2 partial pressure, MEA concentration, CO2 loading, and size of spray nozzle. The performance of the spray column was compared to that of a packed column and showed a promise for CO2 capture application. (C) 2008 Elsevier Ltd. All rights reserved
引用
收藏
页码:205 / 209
页数:5
相关论文
共 50 条
  • [41] CO2 capture using activated carbon synthesized from date stone: breakthrough, equilibrium, and mass-transfer zone
    Danish, Mohd
    Parthasarthy, Vijay
    Al Mesfer, Mohammed K.
    CARBON LETTERS, 2021, 31 (06) : 1261 - 1272
  • [42] HEAT AND MASS-TRANSFER OF SPRAY CANALS
    PORTER, RW
    CHEN, KH
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1974, 96 (03): : 286 - 291
  • [43] Development of Cigarette Carbonaceous Hydrochar/ZIF-67-Based Fluids for CO2 Capture from a Gas Stream in a Packed Column: Mass-Transfer Performance Evaluation
    Jaberi, Hassan
    Mosleh, Soleiman
    Dashtian, Kheibar
    ENERGY & FUELS, 2020, 34 (06) : 7295 - 7306
  • [44] MASS-TRANSFER IN A KUHNI EXTRACTION COLUMN
    KUMAR, A
    HARTLAND, S
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1988, 27 (07) : 1198 - 1203
  • [45] MEA-based CO2 capture: a study focuses on MEA concentrations and process parameters
    Wang, Nan
    Wang, Dong
    Krook-Riekkola, Anna
    Ji, Xiaoyan
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [46] MASS-TRANSFER IN A LARGE BUBBLE COLUMN
    KATAOKA, H
    TAKEUCHI, H
    NAKAO, K
    YAGI, H
    TADAKI, T
    OTAKE, T
    MIYAUCHI, T
    WASHIMI, K
    WATANABE, K
    YOSHIDA, F
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1979, 12 (02) : 105 - 110
  • [47] MASS-TRANSFER IN A RECIRCULATING BUBBLE COLUMN
    LEWIS, DA
    DAVIDSON, JF
    CHEMICAL ENGINEERING SCIENCE, 1985, 40 (11) : 2013 - 2017
  • [48] Efficiency Improvement of CO2 Capture
    Nagy, Tibor
    Koczka, Katalin
    Haaz, Eniko
    Toth, Andras Jozsef
    Racz, Laszlo
    Mizsey, Peter
    PERIODICA POLYTECHNICA-CHEMICAL ENGINEERING, 2017, 61 (01) : 51 - 58
  • [49] A new look to the old solvent: Mass transfer performance and mechanism of CO2 absorption into pure monoethanolamine in a spray column
    Kayahan, Emine
    Di Caprio, Ulderico
    Van den Bogaert, Annelot
    Khan, Mohammed N.
    Bulut, Metin
    Braeken, Leen
    Van Gerven, Tom
    Leblebici, M. Enis
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2023, 184
  • [50] LIMESTONE DISSOLUTION - EFFECTS OF PH, CO2, AND BUFFERS MODELED BY MASS-TRANSFER
    CHAN, PK
    ROCHELLE, GT