Methylmercury determination in seafood by photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry

被引:27
|
作者
Covaci, Eniko [1 ]
Senila, Marin [2 ]
Ponta, Michaela [1 ]
Darvasi, Eugen [1 ]
Petreus, Dorin [3 ]
Frentiu, Maria [2 ]
Frentiu, Tiberiu [1 ]
机构
[1] Babes Bolyai Univ, Fac Chem & Chem Engn, Arany Janos 11, Cluj Napoca 400028, Romania
[2] Natl Inst Res & Dev Optoelect Bucharest, Res Inst Analyt Instrumentat, Donath 67, Cluj Napoca 400293, Romania
[3] Tech Univ Cluj Napoca, Fac Elect Telecommun & Informat Technol, Gh Baritiu 26-28, Cluj Napoca 40002, Romania
关键词
Methylmercury determination; Photo-induced cold vapor generation; Plasma microtorch; Optical emission spectrometry; Thermal decomposition atomic absorption spectrometry; European legislation; ATOMIC-ABSORPTION-SPECTROMETRY; TOTAL MERCURY; SPECIATION ANALYSIS; ANALYTICAL-CHEMISTRY; BIOLOGICAL SAMPLES; INORGANIC MERCURY; WATER; FISH; TISSUE; HG;
D O I
10.1016/j.talanta.2017.04.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-chromatographic method based on double liquid-liquid extraction and measurements by UV photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry was developed and characterized for methylmercury determination in seafood. Samples were prepared following the procedure recommended in JRC Technical Report of European Commission formerly proposed for the determination of methylmercury in seafood by thermal decomposition atomic absorption spectrometry, namely confinement of Hg species in 47% HBr solution, extraction of CH3Hg+ in toluene and back-extraction in 1% L-cysteine aqueous solution. Mercury cold vapor was generated by flow injection UV photo-reduction from CH3Hg+ in 0.6 mol L-1 HCOOH, while quantification was performed against external Hg2+ aqueous standards and measuring Hg 253.652 nm emission using a low power/Ar consumption plasma microtorch (15 W, 100 mL min(-1)) and a low resolution microspectrometer (Ocean Optics). The figures of merit and analytical capability were assessed by analyzing certified reference materials and test samples of fish fillet and discussed in relation with requirements for Hg determination in seafood in European legislation (Decisions 2007/333/EC and 2002/657/EC) as well as compared to performances achieved in thermal decomposition atomic absorption spectrometry. The limit of detection and quantification of 2 mu g kg(-1) and 6 mu g kg(-1) respectively, precision of 2.79.4% and accuracy of 99 +/- 8% of the proposed method for the determination of CH3Hg+ fulfill the demands of European legislation for Hg quantification. The limit of detection and quantification were better than those in the used reference method or other non-/chromatographic methods taken for comparison. The analysis of certified reference materials and the Bland and Altman test performed on 12 test samples confirmed trueness of the proposed method and its reliability for the determination of traces of CH3Hg+ with 95% confidence level. The proposed method fulfills several demands of the eco-scale concept, is sensitive, simple and safe related to sample preparation through elimination of classical, harmful reductants and attractive by using economical miniaturized instrumentation incorporating a low power and low Ar consumption plasma.
引用
收藏
页码:464 / 472
页数:9
相关论文
共 50 条
  • [41] Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk
    Niedobová, Eva
    Machát, Jiří
    Otruba, Vítězslav
    Kanický, Viktor
    Journal of Analytical Atomic Spectrometry, 2005, 20 (09): : 945 - 949
  • [42] Determination of selenium by flow injection hydride generation inductively coupled plasma optical emission spectrometry
    Hernandez, Princess C.
    Tyson, Julian F.
    Uden, Peter C.
    Yates, Dennis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (03) : 298 - 304
  • [43] Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk
    Niedobová, E
    Machát, J
    Otruba, V
    Kanicky, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (09) : 945 - 949
  • [44] Portable photochemical vapor generation-microwave plasma optical emission spectrometer
    Deng, Yujia
    Zeng, Wen
    Jiang, Xiaoming
    Hou, Xiandeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) : 1316 - 1319
  • [45] Determination of mercury in water samples by electrochemical cold vapor generation coupled to microstrip microwave induced helium plasma optical emission spectrometry
    Cerveny, Vaclav
    Horvath, Mark
    Broekaert, Jose A. C.
    MICROCHEMICAL JOURNAL, 2013, 107 : 10 - 16
  • [46] Multivariate optimization of mercury determination by flow injection-cold vapor generation-inductively coupled plasma optical emission spectrometry
    Goncalves dos Santos, Vanessa Cristina
    Grassi, Marco Tadeu
    de Campos, Monica Soares
    Peralta-Zamora, Patricio Guillermo
    Abate, Gilberto
    ANALYST, 2012, 137 (19) : 4458 - 4463
  • [47] Determination of total mercury and methylmercury in biological samples by photochemical vapor generation
    Vieira, Mariana A.
    Ribeiro, Anderson S.
    Curtius, Adilson J.
    Sturgeon, Ralph E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (04) : 837 - 847
  • [48] Determination of total mercury and methylmercury in biological samples by photochemical vapor generation
    Mariana A. Vieira
    Anderson S. Ribeiro
    Adilson J. Curtius
    Ralph E. Sturgeon
    Analytical and Bioanalytical Chemistry, 2007, 388 : 837 - 847
  • [49] UV photochemical vapor generation-nitrogen microwave induced plasma optical emission spectrometric determination of nickel
    Jiang, Xiaoming (jiangxm@scu.edu.cn), 1600, Royal Society of Chemistry (33):
  • [50] UV photochemical vapor generation-nitrogen microwave induced plasma optical emission spectrometric determination of nickel
    Li, Mengtian
    Deng, Yujia
    Jiang, Xiaoming
    Hou, Xiandeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1086 - 1091