Preparation of urine samples for trace metal determination: a study with aluminium analysis by inductively coupled plasma optical emission spectrometry

被引:20
|
作者
Burden, TJ [1 ]
Whitehead, MW [1 ]
Thompson, RPH [1 ]
Powell, JJ [1 ]
机构
[1] St Thomas Hosp, Rayne Inst, Gastrointestinal Lab, London SE1 7EH, England
基金
英国惠康基金;
关键词
X-ray microanalysis;
D O I
10.1177/000456329803500208
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Urinary analysis of trace metals forms a significant role in clinical chemistry, but the optimal preparation and analysis of urine samples has not been investigated. Human urine is generally supersaturated with dissolved solids. Therefore, samples often precipitate following collection. X-ray microanalysis showed that this precipitate was predominantly rich in calcium and phosphorus but could include some trace metals from urine, potentially lowering their concentrations in solution. Hence, the precipitate must be fully redissolved for accurate analysis of trace metals in urine. Methods are emphasized for the best collection and preparation of urine samples for subsequent trace metal analysis; in this work inductively coupled plasma optical emission spectrometry (ICPOES) was used for the analysis of aluminium. For optimal accuracy, peak profiles were collected over 396.147 nm-396.157 nm. Urinary aluminium levels were investigated from 10 healthy volunteers and concentrations were obtained using either aqueous, pooled or individual urine-based standard curves. Since urine has a highly variable matrix, individual sample-based standards, which are unique to that particular sample, gave the most accurate results. However, where sample size is small or sample numbers are unfeasibly large, pooled sample-based standards give good approximations to within 15% and, with appropriate validation, other elements as internal standards could also be used for approximations. Aqueous standards should be avoided. Spike-recovery experiments confirmed these data since individual sample based standards showed optimal recovery [99.3 (4.4)%], while pooled sample-based standards were a close proxy [101.6 (9.2)%] but aqueous standards were inappropriate [137.4 (12.8)%]. Postprandial urinary aluminium levels of the 10 volunteers were [7.2 (3.7)mu g/L] after analysis using individual sample-based standard curves.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 50 条
  • [21] Multielemental determination of trace elements in sewage sludge by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry
    Akatsuki, Shinsuke
    Yamanouchi, Ryoji
    Nakamoto, Yumi
    Yoshizumi, Koji
    Ogaki, Mitsuharu
    Yabutani, Tomoki
    Hayashi, Yukako
    Motonaka, Junko
    BUNSEKI KAGAKU, 2008, 57 (08) : 659 - 666
  • [22] Nano Platinum-Catalyzed Dry Ashing of Flour Samples for the Determination of Trace Metals by Inductively Coupled Plasma Optical Emission Spectrometry
    Sahayam, A. C.
    Venkateswarlu, G.
    Chaurasia, S. C.
    ATOMIC SPECTROSCOPY, 2009, 30 (04) : 139 - 142
  • [23] Heavy metals determination in honey samples using inductively coupled plasma-optical emission spectrometry
    Aghamirlou, Hasan Mohammadi
    Khadem, Monireh
    Rahmani, Abdolrasoul
    Sadeghian, Marzieh
    Mahvi, Amir Hossein
    Akbarzadeh, Arash
    Nazmara, Shahrokh
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2015, 13
  • [24] Determination of key elements in plant samples by inductively coupled plasma optical emission spectrometry with electrothermal vaporization
    Luisa Šerá
    Martin Loula
    Stanislava Matějková
    Oto Mestek
    Chemical Papers, 2019, 73 : 3005 - 3017
  • [25] Evaluation of REE determination in geological samples by inductively coupled plasma emission spectrometry
    Rathi, MS
    Khanna, PP
    Mukherjee, PK
    Saini, NK
    JOURNAL OF THE GEOLOGICAL SOCIETY OF INDIA, 1996, 48 (03) : 325 - 330
  • [26] Determination of lanthanum, scandium, and yttrium in complex geological samples by inductively coupled plasma optical emission spectrometry
    Pazos Marino, Magaly
    Abad Pena, Elizabet
    Argota Coello, Humberto
    Pomares-Alfonso, Mario Simeon
    SPECTROSCOPY LETTERS, 2021, 54 (02) : 122 - 132
  • [27] Determination of key elements in plant samples by inductively coupled plasma optical emission spectrometry with electrothermal vaporization
    Sera, Luisa
    Loula, Martin
    Matejkova, Stanislava
    Mestek, Oto
    CHEMICAL PAPERS, 2019, 73 (12): : 3005 - 3017
  • [28] Heavy metals determination in honey samples using inductively coupled plasma-optical emission spectrometry
    Hasan Mohammadi Aghamirlou
    Monireh Khadem
    Abdolrasoul Rahmani
    Marzieh Sadeghian
    Amir Hossein Mahvi
    Arash Akbarzadeh
    Shahrokh Nazmara
    Journal of Environmental Health Science and Engineering, 13
  • [29] The determination of gold in ore samples by inductively coupled plasma optical emission spectrometry (ICP-OES)
    Sekhar, KC
    Gupta, KK
    Bhattacharya, S
    Chakravarthy, S
    ATOMIC SPECTROSCOPY, 2004, 25 (04) : 165 - 169
  • [30] DETERMINATION OF TIN IN GEOCHEMICAL SAMPLES BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY
    PAHLAVANPOUR, B
    THOMPSON, M
    WALTON, SJ
    JOURNAL OF GEOCHEMICAL EXPLORATION, 1979, 12 (01) : 45 - 55