Preparation of urine samples for trace metal determination: a study with aluminium analysis by inductively coupled plasma optical emission spectrometry

被引:20
|
作者
Burden, TJ [1 ]
Whitehead, MW [1 ]
Thompson, RPH [1 ]
Powell, JJ [1 ]
机构
[1] St Thomas Hosp, Rayne Inst, Gastrointestinal Lab, London SE1 7EH, England
基金
英国惠康基金;
关键词
X-ray microanalysis;
D O I
10.1177/000456329803500208
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Urinary analysis of trace metals forms a significant role in clinical chemistry, but the optimal preparation and analysis of urine samples has not been investigated. Human urine is generally supersaturated with dissolved solids. Therefore, samples often precipitate following collection. X-ray microanalysis showed that this precipitate was predominantly rich in calcium and phosphorus but could include some trace metals from urine, potentially lowering their concentrations in solution. Hence, the precipitate must be fully redissolved for accurate analysis of trace metals in urine. Methods are emphasized for the best collection and preparation of urine samples for subsequent trace metal analysis; in this work inductively coupled plasma optical emission spectrometry (ICPOES) was used for the analysis of aluminium. For optimal accuracy, peak profiles were collected over 396.147 nm-396.157 nm. Urinary aluminium levels were investigated from 10 healthy volunteers and concentrations were obtained using either aqueous, pooled or individual urine-based standard curves. Since urine has a highly variable matrix, individual sample-based standards, which are unique to that particular sample, gave the most accurate results. However, where sample size is small or sample numbers are unfeasibly large, pooled sample-based standards give good approximations to within 15% and, with appropriate validation, other elements as internal standards could also be used for approximations. Aqueous standards should be avoided. Spike-recovery experiments confirmed these data since individual sample based standards showed optimal recovery [99.3 (4.4)%], while pooled sample-based standards were a close proxy [101.6 (9.2)%] but aqueous standards were inappropriate [137.4 (12.8)%]. Postprandial urinary aluminium levels of the 10 volunteers were [7.2 (3.7)mu g/L] after analysis using individual sample-based standard curves.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 50 条
  • [1] Determination of trace metals in urine by direct dilution Inductively Coupled Plasma Optical Emission Spectrometry
    Meza-Figueroa, D.
    Cebrian, M.
    Lopez-Carrillo, L.
    Ostrosky-Wegman, P.
    Torres-Sanchez, L.
    Caldero-Aranda, E.
    EPIDEMIOLOGY, 2008, 19 (01) : S226 - S226
  • [2] Trace Metal Determination in the Medicinal Plant Hyoscyamus (Solanaceae) by Inductively Coupled Plasma Optical Emission Spectrometry
    Keskin, Cumali
    Kisin, Erdener
    Yavuz, Murat
    ATOMIC SPECTROSCOPY, 2014, 35 (05) : 193 - 199
  • [3] Determination of Trace Heavy Metal Elements in Plant Essential Oils by Inductively Coupled Plasma Optical Emission Spectrometry
    Li Ai-yang
    Fu Liang
    Chen Lin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (04) : 1162 - 1167
  • [4] DETERMINATION OF PHOSPHORUS IN VARIOUS SAMPLES BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY
    KAWAGUCHI, H
    ITO, T
    MIZUIKE, A
    BUNSEKI KAGAKU, 1978, 27 (01) : 53 - 57
  • [5] Determination of inorganic elements in geopropolis samples by inductively coupled plasma optical emission spectrometry
    Siqueira, Jean Sanger
    Mescouto, Cleide Samara Tavares
    Lemos, Michelle de Souza
    Junior, Joao Batista Pereira
    Venturieri, Giorgio C.
    Dantas Filho, Heronides Adonias
    Dantas, Kelly das Gracas Fernandes
    JOURNAL OF APICULTURAL RESEARCH, 2022, 61 (03) : 400 - 407
  • [6] Determination of trace elements in refined gold samples by inductively coupled plasma atomic emission spectrometry
    Steharnik, Mirjana
    Todorovic, Marija
    Manojlovic, Dragan
    Stankovic, Dalibor
    Mutic, Jelena
    Trujic, Vlastimir
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (04) : 565 - 577
  • [7] Determination of minor and trace elements in urine reference sample by a combined system of inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry
    Fujimori, E
    Sawatari, H
    Chiba, K
    Haraguchi, H
    ANALYTICAL SCIENCES, 1996, 12 (03) : 465 - 470
  • [8] SIMULTANEOUS DETERMINATION OF TRACE-ELEMENTS IN URINE BY INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY
    HAAS, WJ
    FASSEL, VA
    KNISELEY, RN
    SUTHERLAND, WL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 174 (SEP): : 35 - 35
  • [9] Determination of Seventeen Trace Elements in Human Urine by Inductively Coupled Plasma-Atomic Emission Spectrometry
    Shen, Min
    Zhang, Shun-Xiang
    Liu, Gui-Hua
    Zhang, Chao-Yang
    Tang, Jin-Xuan
    Shi, Lu-Yuan
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2002, 22 (02): : 312 - 313
  • [10] Determination of seventeen trace elements in human urine by inductively coupled plasma-atomic emission spectrometry
    Shen, M
    Zhang, SX
    Liu, GH
    Zhang, CY
    Tang, JX
    Shi, LY
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (02) : 311 - 313