Square wave voltammetric determination of nitrofurantoin in pharmaceutical formulations on highly boron-doped diamond electrodes at different boron-doping contents

被引:56
|
作者
de Lima-Neto, Pedro [1 ]
Correia, Adriana N. [1 ]
Portela, Rafael R. [1 ]
Juliao, Murilo da Silva [2 ]
Linhares-Junior, Gilberto F. [3 ]
de Lima, Janete E. S. [3 ]
机构
[1] Univ Fed Ceara, Ctr Ciencias, Dept Quim Analit & Fisicoquim, BR-60455970 Fortaleza, Ceara, Brazil
[2] Univ Estadual Vale Acarau, Ctr Ciencias Exatas & Tecnol, BR-62040370 Sobral, CE, Brazil
[3] Univ Fed Ceara, Dept Farm, Fac Farm Odontol & Enfermagem, BR-60430370 Fortaleza, Ceara, Brazil
关键词
Boron-doped diamond film electrode; Nitrofurantoin; Cyclic voltammetry; Square wave voltammetry; Electroanalytical determination; ELECTROANALYTICAL CHEMISTRY; CARBON NANOTUBES; URINE; BEHAVIOR; ELECTROCHEMISTRY; PLASMA; DRUG;
D O I
10.1016/j.talanta.2009.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NET determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i e.5000. 10,000 and 20,000 mg L(-1)) The level of boron-doping ill the diamond film electrodes influenced the electrochemical reduction of NET. The appropriate cyclic voltammetric response of NET was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L-1 of boron These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NET concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20.000 mg L(-1) of boron were 269 x 10(-8) mol L(-1) (6 40 mu g L(-1)) and 8 15 x 10(-9) mol L(-1) (1 94 mu g L(-1)), respectively. while the lower limits of quantification were 8.96 x 10(-8) mol L(-1) (21 33 mu g L(-1)) and 2.72 x 10(-8) mol L(-1) (6.47 mu g L(-1)), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NET and did not require complex preparations or renovations of the electrode surface This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 50 条
  • [31] Simultaneous square-wave voltammetric determination of aspartame and cyclamate using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    de Carvalho, Adriana Evaristo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2008, 76 (03) : 685 - 689
  • [32] Voltammetric characterization of boron-doped diamond electrodes for electroanalytical applications
    Rehacek, V.
    Hotovy, I.
    Marton, M.
    Mikolasek, M.
    Michniak, P.
    Vincze, A.
    Kromka, A.
    Vojs, M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 862
  • [33] Electroanalytical determination of lidocaine in pharmaceutical preparations using boron-doped diamond electrodes
    Oliveira, Robson T. S.
    Salazar-Banda, Giancarlo R.
    Ferreira, Valdir S.
    Oliveira, Silvio C.
    Avaca, Luis A.
    ELECTROANALYSIS, 2007, 19 (11) : 1189 - 1194
  • [34] Square-wave voltammetric determination of hydroxychloroquine in pharmaceutical and synthetic urine samples using a cathodically pretreated boron-doped diamond electrode
    Deroco, Patricia Batista
    Vicentini, Fernando Campanha
    Oliveira, Geiser Gabriel
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 719 : 19 - 23
  • [35] Sensitive square-wave voltammetric determination of tadalafil (Cialis®) in pharmaceutical samples using a cathodically pretreated boron-doped diamond electrode
    Sartori, Elen Romao
    Clausen, Debora Nobile
    Ruiz Pires, Igor Matheus
    Rossi Salamanca-Neto, Carlos Alberto
    DIAMOND AND RELATED MATERIALS, 2017, 77 : 153 - 158
  • [36] Voltammetric Determination of Antidepressant Imipramine in Pharmaceutical Preparations Using Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Matokarova, Martina
    Salusova, Ivana
    Plankova, Alexandra
    Brtkova, Barbora
    Borovska, Katarina
    Marton, Marian
    Vojs, Marian
    Svorc, L'ubomir
    CHEMICKE LISTY, 2017, 111 (06): : 392 - 397
  • [37] Chlorine evolution at highly boron-doped diamond electrodes
    Ferro, S
    De Battisti, A
    Duo, I
    Comninellis, C
    Haenni, W
    Perret, A
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (07) : 2614 - 2619
  • [38] Voltammetric determination of antifungal agents in pharmaceuticals and cosmetics using boron-doped diamond electrodes
    Mielech-Lukasiewicz, Katarzyna
    Roginska, Katarzyna
    ANALYTICAL METHODS, 2014, 6 (19) : 7912 - 7922
  • [39] Simultaneous Differential Pulse Voltammetric Determination of Ascorbic Acid and Caffeine in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2010, 22 (15) : 1717 - 1723
  • [40] Square-Wave Voltammetric Determination of Antihistaminic Drug Hydroxyzine in Pharmaceuticals Using a Boron-doped Diamond Electrode
    Scremin, Jessica
    Sartori, Elen Romao
    ORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY, 2016, 8 (03): : 174 - 180