Square wave voltammetric determination of nitrofurantoin in pharmaceutical formulations on highly boron-doped diamond electrodes at different boron-doping contents

被引:56
|
作者
de Lima-Neto, Pedro [1 ]
Correia, Adriana N. [1 ]
Portela, Rafael R. [1 ]
Juliao, Murilo da Silva [2 ]
Linhares-Junior, Gilberto F. [3 ]
de Lima, Janete E. S. [3 ]
机构
[1] Univ Fed Ceara, Ctr Ciencias, Dept Quim Analit & Fisicoquim, BR-60455970 Fortaleza, Ceara, Brazil
[2] Univ Estadual Vale Acarau, Ctr Ciencias Exatas & Tecnol, BR-62040370 Sobral, CE, Brazil
[3] Univ Fed Ceara, Dept Farm, Fac Farm Odontol & Enfermagem, BR-60430370 Fortaleza, Ceara, Brazil
关键词
Boron-doped diamond film electrode; Nitrofurantoin; Cyclic voltammetry; Square wave voltammetry; Electroanalytical determination; ELECTROANALYTICAL CHEMISTRY; CARBON NANOTUBES; URINE; BEHAVIOR; ELECTROCHEMISTRY; PLASMA; DRUG;
D O I
10.1016/j.talanta.2009.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NET determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i e.5000. 10,000 and 20,000 mg L(-1)) The level of boron-doping ill the diamond film electrodes influenced the electrochemical reduction of NET. The appropriate cyclic voltammetric response of NET was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L-1 of boron These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NET concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20.000 mg L(-1) of boron were 269 x 10(-8) mol L(-1) (6 40 mu g L(-1)) and 8 15 x 10(-9) mol L(-1) (1 94 mu g L(-1)), respectively. while the lower limits of quantification were 8.96 x 10(-8) mol L(-1) (21 33 mu g L(-1)) and 2.72 x 10(-8) mol L(-1) (6.47 mu g L(-1)), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NET and did not require complex preparations or renovations of the electrode surface This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 50 条
  • [1] Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode
    Ardila, Jorge Armando
    Sartori, Elen Romao
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2013, 103 : 201 - 206
  • [2] Electroanalytical determination of promethazine hydrochloride in pharmaceutical formulations on highly boron-doped diamond electrodes using square-wave adsorptive voltammetry
    Ribeiro, Francisco Wirley P.
    Cardoso, Amanda S.
    Portela, Rafael R.
    Lima, Janete E. S.
    Machado, Sergio A. S.
    de Lima-Neto, Pedro
    De Souza, Djenaine
    Correia, Adriana N.
    ELECTROANALYSIS, 2008, 20 (18) : 2031 - 2039
  • [3] Analytical determination of aliskiren in pharmaceutical formulations using boron-doped diamond electrodes
    Carvalho, Flavio H. O.
    Cintra, Alessandra
    Abrahao, Odonirio
    Gomes, Roseli A. S.
    Salazar-Banda, Giancarlo R.
    Oliveira, Robson T. S.
    ANALYTICAL METHODS, 2015, 7 (18) : 7461 - 7466
  • [4] Electroanalytical Determination of Captopril in Pharmaceutical Formulations Using Boron-Doped Diamond Electrodes
    Ferreira Vitoreti, Ana B.
    Abrahao, Odonirio
    da Silva Gomes, Roseli A.
    Salazar-Banda, Giancarlo R.
    Oliveira, Robson T. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1044 - 1054
  • [5] Comparison Study of Voltammetric Determination of Dantrolene using Boron-Doped Diamond Electrodes With Different Content of Boron
    Martinkova, Pavlina
    Selesovska, Renata
    Chylkova, Jaromira
    Behul, Miroslav
    XXXVII MODERNI ELEKTROCHEMICKE METODY, 2017, : 142 - 146
  • [6] Voltammetric Determination of Ethionamide in Pharmaceutical Formulations and Human Urine using a Boron-Doped Diamond Electrode
    Ferraz, Bruno R. L.
    Leite, Fernando R. F.
    Batista, Bruna L.
    Malagutti, Andrea R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (04) : 677 - 684
  • [7] Simultaneous voltammetric determination of paracetamol and caffeine in pharmaceutical formulations using a boron-doped diamond electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Mazo, Luiz Henrique
    Fatibello-Filho, Orlando
    TALANTA, 2009, 78 (03) : 748 - 752
  • [8] Evaluation of boron-doped diamond electrode for simultaneous voltammetric determination of hydrochlorothiazide and losartan in pharmaceutical formulations
    Gardenal Santos, Michely Cristina
    Teixeira Tarley, Cesar Ricardo
    Dall'Antonia, Luiz Henrique
    Sartori, Elen Romao
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 263 - 270
  • [9] Electrochemical reduction of nitrate on boron-doped diamond electrodes: Effects of surface termination and boron-doping level
    Kuang, Peijing
    Natsui, Keisuke
    Feng, Chuanping
    Einaga, Yasuaki
    CHEMOSPHERE, 2020, 251
  • [10] Voltammetric assay of naproxen in pharmaceutical formulations using boron-doped diamond electrode
    Suryanarayan, V
    Zhang, Y
    Yoshihara, S
    Shirakashi, T
    ELECTROANALYSIS, 2005, 17 (11) : 925 - 932