A Virtual Reality System to Train Image Guided Placement of Kirschner-Wires for Distal Radius Fractures

被引:0
|
作者
Seah, Tian En Timothy [1 ]
Barrow, Alastair [1 ]
Baskaradas, Aroon [2 ]
Gupte, Chinmay [2 ]
Bello, Fernando [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, St Marys Hosp, Dept Surg & Canc, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, St Marys Hosp, Imperial Coll Healthcare NHS Trust, London SW7 2AZ, England
来源
BIOMEDICAL SIMULATION | 2014年 / 8789卷
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
We present the design, development and initial user testing of a virtual reality simulator to train orthopaedic surgeons in the optimal placement of K-wires for fixation of distal radius fractures. Our platform includes 5 DOF haptic feedback to recreate the manual skill aspects of the drilling process, a 3D view of the anatomy and a controllable x-ray image. Once complete, the user is given an overview of their performance compared with the 'ideal placement' defined by an expert orthopaedic surgeon. The design goals based on analysis of the core steps in the procedure are presented, along with the technical implementation in terms of both haptic and graphical feedback. Preliminary user testing results are discussed, together with current limitations and planned future development.
引用
收藏
页码:20 / 29
页数:10
相关论文
共 29 条
  • [11] Radiological outcomes of distal radius extra-articular fragility fractures treated with extra-focal kirschner wires
    Kennedy, C.
    Kennedy, M. T.
    Niall, D.
    Devitt, A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (06): : 639 - 642
  • [12] CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results
    Rieger, M
    Gabl, M
    Gruber, H
    Jaschke, WR
    Mallouhi, A
    EUROPEAN RADIOLOGY, 2005, 15 (04) : 792 - 797
  • [13] CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results
    Michael Rieger
    Markus Gabl
    Hannes Gruber
    Werner R. Jaschke
    Ammar Mallouhi
    European Radiology, 2005, 15 : 792 - 797
  • [14] Virtual guidance versus virtual implant planning system in the treatment of distal radius fractures
    Vetter, Sven Yves
    Magaraggia, Jessica
    Beisemann, Nils
    Schnetzke, Marc
    Keil, Holger
    Franke, Jochen
    Gruetzner, Paul Alfred
    Swartman, Benedict
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (05):
  • [15] LONG-TERM FOLLOW-UP OF TREATMENT OF COMMINUTED FRACTURES OF THE DISTAL END OF THE RADIUS BY TRANSFIXATION WITH KIRSCHNER WIRES AND CAST
    SCHECK, M
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1962, 44 (02): : 337 - 351
  • [16] Die Versorgung der distalen RadiusfrakturKirschner-Draht-Osteosynthese oder palmare winkelstabile Platte?Treatment of distal radius fracturesPercutaneous Kirschner-wires or palmar locking plates?
    R. Meier
    C. Krettek
    C. Probst
    Der Unfallchirurg, 2012, 115 (7): : 598 - 607
  • [17] LONG-TERM FOLLOW-UP OF TREATMENT OF COMMINUTED FRACTURES OF THE DISTAL END OF THE RADIUS BY TRANSFIXATION WITH KIRSCHNER WIRES AND CAST
    SCHECK, M
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (02): : 316 - 316
  • [18] A comparative study of functional outcome of treatment of intra articular fractures of distal radius fixed with percutaneous Kirschner's wires vs T-plate
    Khan, Jahangir Iqbal
    Hussain, Faisal Nazeer
    Mehmood, Tahir
    Adil, Omer
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (03) : 709 - 713
  • [19] Biomechanical evaluation of fixation of intra-articular fractures of the distal part of the radius in cadavera: Kirschner wires compared with calcium-phosphate bone cement
    Yetkinler, DN
    Ladd, AL
    Poser, RD
    Constantz, BR
    Carter, D
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (03): : 391 - 399
  • [20] Three-dimensional image-guided placement of percutaneous pedicle screws without the use of biplanar fluoroscopy or Kirschner wires: technical note
    Nottmeier, Eric W.
    Fenton, Douglas
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2010, 6 (04): : 483 - 488