Condition assessment of XLPE insulated cables using isothermal relaxation current technique

被引:0
|
作者
Oyegoke, Bolarin S. [1 ]
Foottit, Frith [1 ]
Birtwhistle, David [1 ]
Lyall, Jim [1 ]
Wickramasuriya, Prasanna B. [2 ]
机构
[1] Queensland Univ Technol, Brisbane, Qld 4001, Australia
[2] Ergon Energy, Virginia, Australia
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Isothermal Relaxation Current (IRC) method of assessing the condition of power cable insulation has been in use for more than 10 years. The method is based on a relaxation model of the thermal release of carriers from traps. An empirical aging factor often called A-factor determined from IRC analysis is investigated using measured depolarization currents from laboratory and field aged cables. Measurement results presented here indicate that calculation of A-factor depends on how well the software of the measuring system in IRC test set is able to approximate the measured depolarization current data. It is found that wrong approximation of measured data may result especially when the current decay is not monotonically decaying with time. For a better use of this equipment it is propose that the user make use of the raw depolarization current data instead of the A-factor output from the test system.
引用
收藏
页码:4339 / +
页数:2
相关论文
共 50 条
  • [21] Condition assessment of XLPE cable insulation using short-time polarisation and depolarisation current measurements
    Oyegoke, B.
    Birtwhistle, D.
    Lyall, J.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2008, 2 (01) : 25 - 31
  • [22] A Novel Condition Assessment Method for Corrugated Aluminum Sheathed XLPE Cables Based on Evolved Gas Analysis
    Kong, Jiamin
    Zhou, Kai
    Chen, Yidong
    Meng, Pengfei
    Li, Yuan
    Ren, Xiancheng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (02) : 883 - 891
  • [23] Diagnostic study of electrical treeing in underground XLPE cables using acoustic emission technique
    Sarathi, R
    Raju, PG
    POLYMER TESTING, 2004, 23 (08) : 863 - 869
  • [24] A new approach for the failure prediction in XLPE power cables using acoustic emission technique
    Jabha, D. F. Jingle
    Selvi, K.
    Joselin, R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 81 : 336 - 345
  • [25] Assessment of the State of Electrical Insulation by Measuring Isothermal Relaxation Current
    Kononenko A.I.
    Kononenko, A.I. (aikononeko@niipribor.ru), 2018, Springer Science and Business Media, LLC (52) : 95 - 101
  • [26] A novel approach for the failure prediction in XLPE power cables using acoustic emission technique
    Jabha, D. F. Jingle
    Joselin, R.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2025, 40 (02) : 784 - 798
  • [27] Condition Evaluation of MV XLPE Cable with Step-rise Breakdown and Relaxation Current Method
    Zhu, Yonghua
    Jia, Xin
    Yang, Juanjuan
    Wu, Changshun
    Yuan, Changjun
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 704 - 707
  • [28] Exploration of Pt-doped Janus WSSe monolayer as a typical gas sensor for condition assessment in XLPE cables
    Ye, Helin
    Liu, Song
    Peng, Kai
    Zheng, Qiongling
    Hu, Jian
    Cui, Hao
    CHEMICAL PHYSICS LETTERS, 2023, 832
  • [29] Condition monitoring of 11 kv paper insulated cables using self-organising maps
    Arroyo, JMR
    Beddoes, AJ
    Allinson, NM
    CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING 2001, VOLS I AND II, CONFERENCE PROCEEDINGS, 2001, : 259 - 264
  • [30] Space charge studies of aged XLPE using combined isothermal and thermostimulated current measurements
    Lança, MC
    Neagu, ER
    Marat-Mendes, JN
    CROSS-DISCIPLINARY APPLIED RESEARCH IN MATERIALS SCIENCE AND TECHNOLOGY, 2005, 480 : 501 - 505