Magnetic molecularly imprinted polymer based - micro-solid phase extraction of cocaine and metabolites in plasma followed by high performance liquid chromatography - tandem mass spectrometry

被引:18
|
作者
Sanchez-Gonzalez, Juan [1 ]
Barreiro-Grille, Tania [1 ]
Cabarcos, Pamela [2 ]
Jesus Tabernero, Maria [2 ]
Bermejo-Barrera, Pilar [1 ]
Moreda-Pineiro, Antonio [1 ]
机构
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Ave Ciencias S-N, Santiago De Compostela 15782, Spain
[2] Univ Santiago de Compostela, Fac Med, Dept Pathol Anat & Forens Sci, Rua San Francisco S-N, Santiago De Compostela 15782, Spain
关键词
Magnetic molecularly imprinted polymer; Plasma; Cocaine; HPLC-MS/MS; ENVIRONMENTAL WATER SAMPLES; SELECTIVE EXTRACTION; BOVINE HEMOGLOBIN; AQUEOUS-SOLUTION; RHODAMINE-B; NANOPARTICLES; RECOGNITION; URINE; MICROEXTRACTION; ANTIBIOTICS;
D O I
10.1016/j.microc.2016.03.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel adsorbent, magnetic molecularly imprinted polymer (MMIP) based on magnetite nanoparticles surface covered with an MIP selective for cocaine (COC), was synthesised and used in batch micro-solid phase extraction (mu-SPE) for isolation of COC and metabolites (benzoylecgonine, BZE; cocaethylene, CE; and ecgonine methyl ester, EME) from plasma samples. High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was used for performing analysis. Parameters such as sample pH, magnetic stirring speed, extraction temperature and time (loading stage), composition and volume of the eluting solution, and desorption time, were optimised. Under the most favourable conditions, the highest extraction yields were obtained by using 0.1 to 1.0 mL of plasma (pH adjusted at 8.5) plus 50 mg of MMIP, and magnetic stirring (20 degrees C, 100 rpm) for 4 min. Elution was performed with 2 mL of a dichloromethane/2-propanol/ammonium hydroxide (75:20:5) mixture under ultrasound irradiation (325 W, 35 kHz) for 5 min. The limits of detection were between 0.013 and 036 ng L-1, and the limits of quantification were from 0.043 to 1.2 ng L-1. The relative standard deviations of intra- and inter-day tests (three concentration levels tested) ranged from 1 to 9% and from 2 to 10%, respectively. Analytical recoveries were in the range of 91-102% when spiking drug-free plasma samples at three concentration levels. Accurate results were also obtained after analysing a BTMF 1/11-B control material. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [21] Molecularly Imprinted Polymer Solid Phase Extraction followed by High-Performance Liquid Chromatography as an Efficient and Sensitive Technique for Determination of Meropenem in Human Plasma and Urine
    Amlashi, Hamoon Sami
    Daryasari, Ameneh Porgham
    Soleimani, Mojtaba
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2019, 72 : 32 - 39
  • [22] Determination of β2-Agonists in Porcine Urine by Molecularly Imprinted Solid Phase Extraction Followed Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Detection
    Wang, Peilong
    Li, Yang
    Wang, Ruiguo
    Zhang, Wei
    Cheng, Jie
    Wang, Jing
    Su, Xiaoou
    Ye, Zhihua
    ANALYTICAL LETTERS, 2013, 46 (05) : 734 - 744
  • [23] Simultaneous Determination of 11 Aminoglycoside Residues in Honey, Milk, and Pork by Liquid Chromatography with Tandem Mass Spectrometry and Molecularly Imprinted Polymer Solid Phase Extraction
    Yang, Bixia
    Wang, Lian
    Luo, Chunying
    Wang, Xixi
    Sun, Chengjun
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (06) : 1869 - 1878
  • [24] Magnetic Molecularly Imprinted Polymer Particles Based Micro-Solid Phase Extraction for the Determination of 4-Nitrophenol in Lake Water
    Yigaimu, Aziguli
    Muhammad, Turghun
    Yang, Wenwu
    Muhammad, Imran
    Wubulikasimu, Muyasier
    Piletsky, Sergey A.
    MACROMOLECULAR RESEARCH, 2019, 27 (11) : 1089 - 1094
  • [25] Magnetic Molecularly Imprinted Polymer Particles Based Micro-Solid Phase Extraction for the Determination of 4-Nitrophenol in Lake Water
    Aziguli Yigaimu
    Turghun Muhammad
    Wenwu Yang
    Imran Muhammad
    Muyasier Wubulikasimu
    Sergey A. Piletsky
    Macromolecular Research, 2019, 27 : 1089 - 1094
  • [26] Sensitive detection of β-agonists in pork tissue with novel molecularly imprinted polymer extraction followed liquid chromatography coupled tandem mass spectrometry detection
    Wang, Peilong
    Liu, Ximeng
    Su, Xiaoou
    Zhu, Ruohua
    FOOD CHEMISTRY, 2015, 184 : 72 - 79
  • [27] DETERMINATION OF TETRACYCLINES BY SOLID-PHASE EXTRACTION WITH A MOLECULARLY IMPRINTED POLYMER AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Carvalho Abrao, Lailah Cristina
    Maia, Patricia Penido
    Figueiredo, Eduardo Costa
    ANALYTICAL LETTERS, 2014, 47 (13) : 2183 - 2194
  • [28] Magnetic dispersive solid-phase extraction based on modified magnetic nanoparticles for the detection of cocaine and cocaine metabolites in human urine by high-performance liquid chromatography-mass spectrometry
    Yang, Feiyu
    Zou, Yun
    Ni, Chunfang
    Wang, Rong
    Wu, Min
    Liang, Chen
    Zhang, Jiabin
    Yuan, Xiaoliang
    Liu, Wenbin
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (21) : 4234 - 4245
  • [29] An insulin monitoring device based on hyphenation between molecularly imprinted micro-solid phase extraction and complementary molecularly imprinted polymer-sensor
    Tiwari, Mahavir Prasad
    Prasad, Bhim Bali
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1337 : 22 - 31
  • [30] Analysis of alternariol and alternariol monomethyl ether in foodstuffs by molecularly imprinted solid-phase extraction and ultra-high-performance liquid chromatography tandem mass spectrometry
    Rico-Yuste, A.
    Walravens, J.
    Urraca, J. L.
    Abou-Hany, R. A. G.
    Descalzo, A. B.
    Orellana, G.
    Rychlik, M.
    De Saeger, S.
    Moreno-Bondi, M. C.
    FOOD CHEMISTRY, 2018, 243 : 357 - 364