Optical fiber biosensor for the determination of low biochemical oxygen demand

被引:73
|
作者
Chee, GJ [1 ]
Nomura, Y [1 ]
Ikebukuro, K [1 ]
Karube, I [1 ]
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
来源
BIOSENSORS & BIOELECTRONICS | 2000年 / 15卷 / 7-8期
关键词
BOD sensor; biosensor; Pseudomonas putida; artificial wastewater; optical fiber sensor; fluorescence;
D O I
10.1016/S0956-5663(00)00093-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An optical fiber biosensor was developed for the evaluation of low Biochemical Oxygen Demand (BOD) values in river waters. Artificial wastewater (AWW) solution was employed as standards for the calibration of the BOD sensor. The response time of the sensor was 15 min, and the optimal BOD response was observed at 30 degreesC, pH 7.0. A linear relationship was obtained between the output voltage and BOD, values, and the range of determination was 1-10 mg l(-1) BOD. The sensor response was almost not influenced by chloride ion up to 1000 mg l(-1), and also not affected by heavy metal ions (Fe(3+), Cu(2+), Mn(2+), Cr(3+), Zn(2+)). The BOD of river waters was estimated by using the optical fiber biosensor, and good correlation between the sensor and BOD, test was obtained (r(2) = 0.971). (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:371 / 376
页数:6
相关论文
共 50 条
  • [31] Microbial fuel cell biosensor for the determination of biochemical oxygen demand of wastewater samples containing readily and slowly biodegradable organics
    Tardy, Gabor Mark
    Lorant, Balint
    Gyalai-Korpos, Miklos
    Bakos, Vince
    Simpson, David
    Goryanin, Igor
    BIOTECHNOLOGY LETTERS, 2021, 43 (02) : 445 - 454
  • [32] Rapid Determination of the Chemical Oxygen Demand of Water Using a Thermal Biosensor
    Yao, Na
    Wang, Jinqi
    Zhou, Yikai
    SENSORS, 2014, 14 (06): : 9949 - 9960
  • [33] A comparison of the graphical and standard methods for the determination of biochemical oxygen demand
    Woodring, S.L.
    Clifford, D.A.
    Journal of the Water Pollution Control Federation, 1988, 60 (04): : 537 - 542
  • [34] Immobilized multi-species based biosensor for rapid biochemical oxygen demand measurement
    Liu, Changyu
    Ma, Chao
    Yu, Dengbin
    Jia, Jianbo
    Liu, Ling
    Zhang, Bailin
    Dong, Shaojun
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2074 - 2079
  • [35] A NOVEL BIOSENSOR BASED ON MICROBIAL ELECTROLYSIS CELL FOR RAPID ANALYSIS OF BIOCHEMICAL OXYGEN DEMAND
    Jiang, Haiming
    Si, Wantong
    Li, Xia
    FRESENIUS ENVIRONMENTAL BULLETIN, 2017, 26 (05): : 3455 - 3464
  • [36] FIBER OPTICAL FLUOROSENSOR FOR DETERMINATION OF HALOTHANE AND OR OXYGEN
    WOLFBEIS, OS
    POSCH, HE
    KRONEIS, HW
    ANALYTICAL CHEMISTRY, 1985, 57 (13) : 2556 - 2561
  • [37] DETERMINATION OF THE BIOCHEMICAL OXYGEN-DEMAND (BOD5) BY DIRECT COULOMETRIC DETERMINATION OF THE OXYGEN CONSUMED
    GANTNER, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 299 (01): : 42 - 45
  • [38] Development of a luminescence-based biosensor for biological oxygen demand determination.
    Kwok, NY
    Wong, KY
    Lo, WH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U73 - U73
  • [39] Effects of dilution on dissolved oxygen depletion and microbial populations in the biochemical oxygen demand determination
    Seo, Kyo Seong
    Chang, Ho Nam
    Park, Joong Kon
    Choo, Kwang-Ho
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2007, 76 (04) : 951 - 956
  • [40] Effects of dilution on dissolved oxygen depletion and microbial populations in the biochemical oxygen demand determination
    Kyo Seong Seo
    Ho Nam Chang
    Joong Kon Park
    Kwang-Ho Choo
    Applied Microbiology and Biotechnology, 2007, 76 : 951 - 956