Diagnostic Accuracy of Community-Based Diabetic Retinopathy Screening With an Offline Artificial Intelligence System on a Smartphone

被引:143
|
作者
Natarajan, Sundaram [1 ]
Jain, Astha [1 ]
Krishnan, Radhika [1 ]
Rogye, Ashwini [1 ]
Sivaprasad, Sobha [2 ]
机构
[1] Aditya Jyot Fdn Twinkling Little Eyes, 153 Major Parmeswaran Rd, Mumbai 400031, Maharashtra, India
[2] Moorfields Eye Hosp, London, England
基金
英国医学研究理事会;
关键词
VALIDATION; PROGRAM;
D O I
10.1001/jamaophthalmol.2019.2923
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Offline automated analysis of retinal images on a smartphone may be a cost-effective and scalable method of screening for diabetic retinopathy; however, to our knowledge, assessment of such an artificial intelligence (AI) system is lacking. OBJECTIVE To evaluate the performance of Medios AI (Remidio), a proprietary, offline, smartphone-based, automated system of analysis of retinal images, to detect referable diabetic retinopathy (RDR) in images taken by a minimally trained health care worker with Remidio Non-Mydriatic Fundus on Phone, a smartphone-based, nonmydriatic retinal camera. Referable diabetic retinopathy is defined as any retinopathy more severe than mild diabetic retinopathy, with or without diabetic macular edema. DESIGN, SETTING, AND PARTICIPANTS This prospective, cross-sectional, population-based study took place from August 2018 to September 2018. Patients with diabetes mellitus who visited various dispensaries administered by the Municipal Corporation of Greater Mumbai in Mumbai, India, on a particular day were included. INTERVENTIONS Three fields of the fundus (the posterior pole, nasal, and temporal fields) were photographed. The images were analyzed by an ophthalmologist and the AI system. MAIN OUTCOMES AND MEASURES To evaluate the sensitivity and specificity of the offline automated analysis system in detecting referable diabetic retinopathy on images taken on the smartphone-based, nonmydriatic retinal imaging system by a health worker. RESULTS Of 255 patients seen in the dispensaries, 231 patients (90.6%) consented to diabetic retinopathy screening. The major reasons for not participating were unwillingness to wait for screening and the blurring of vision that would occur after dilation. Images from 18 patients were deemed ungradable by the ophthalmologist and hence were excluded. In the remaining participants (110 female patients [51.6%] and 103 male patients [48.4%]; mean [SD] age, 53.1 [10.3] years), the sensitivity and specificity of the offline AI system in diagnosing referable diabetic retinopathy were 100.0% (95% CI, 78.2%-100.0%) and 88.4% (95% CI, 83.2%-92.5%), respectively, and in diagnosing any diabetic retinopathy were 85.2% (95% CI, 66.3%-95.8%) and 92.0% (95% CI, 97.1%-95.4%), respectively, compared with ophthalmologist grading using the same images. CONCLUSIONS AND RELEVANCE These pilot study results show promise in the use of an offline AI system in community screening for referable diabetic retinopathy with a smartphone-based fundus camera. The use of AI would enable screening for referable diabetic retinopathy in remote areas where services of an ophthalmologist are unavailable. This study was done on patients with diabetes who were visiting a dispensary that provides curative services to the population at the primary level. A study with a larger sample size may be needed to extend the results to general population screening, however.
引用
收藏
页码:1182 / 1188
页数:7
相关论文
共 50 条
  • [31] Screening for Diabetic Retinopathy Using an Automated Diagnostic System Based on Deep Learning: Diagnostic Accuracy Assessment
    Rego, Silvia
    Dutra-Medeiros, Marco
    Soares, Filipe
    Monteiro-Soares, Matilde
    OPHTHALMOLOGICA, 2021, 244 (03) : 250 - 257
  • [32] Prospective studies on artificial intelligence (AI)-based diabetic retinopathy screening
    Nanegrungsunk, Onnisa
    Ruamviboonsuk, Paisan
    Grzybowski, Andrzej
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (24)
  • [33] Pilot Artificial Intelligence based Diabetic Retinopathy Screening Programme in Poland
    Grzybowski, A.
    Brona, P.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (1_SUPPL) : 25 - 26
  • [34] Evaluation of a novel artificial intelligence-based screening system for diabetic retinopathy in community of China: a real-world study
    Ming, Shuai
    Xie, Kunpeng
    Lei, Xiang
    Yang, Yingrui
    Zhao, Zhaoxia
    Li, Shuyin
    Jin, Xuemin
    Lei, Bo
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (04) : 1291 - 1299
  • [35] Evaluation of a novel artificial intelligence-based screening system for diabetic retinopathy in community of China: a real-world study
    Shuai Ming
    Kunpeng Xie
    Xiang Lei
    Yingrui Yang
    Zhaoxia Zhao
    Shuyin Li
    Xuemin Jin
    Bo Lei
    International Ophthalmology, 2021, 41 : 1291 - 1299
  • [36] Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy
    Huang, Xuan
    Wang, Hui
    She, Chongyang
    Feng, Jing
    Liu, Xuhui
    Hu, Xiaofeng
    Chen, Li
    Tao, Yong
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [37] Will artificial intelligence replace ophthalmologist in diabetic retinopathy screening?
    You, Zhipeng
    Hu, Xiaoqin
    Shi, Ke
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (15): : 6920 - 6920
  • [38] Diabetic retinopathy screening in the emerging era of artificial intelligence
    Grauslund, Jakob
    DIABETOLOGIA, 2022, 65 (09) : 1415 - 1423
  • [39] Artificial intelligence in diabetic retinopathy screening: Mind the workflow
    Perilli, Roberto
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025, 35 (02) : NP61 - NP62
  • [40] Artificial intelligence for diabetic retinopathy screening, prediction and management
    Gunasekeran, Dinesh V.
    Ting, Daniel S. W.
    Tan, Gavin S. W.
    Wong, Tien Y.
    CURRENT OPINION IN OPHTHALMOLOGY, 2020, 31 (05) : 357 - 365