Rolled-up SiOx/SiNx microtubes with an enhanced quality factor for sensitive solvent sensing

被引:13
|
作者
Song, Pengfei [1 ,2 ]
Chen, Cheng [3 ]
Qu, Juntian [1 ,2 ]
Ou, Pengfei [3 ]
Dastjerdi, M. H. T. [4 ,5 ]
Mi, Zetian [4 ,6 ]
Song, Jun [3 ]
Liu, Xinyu [1 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, 5 Kings Coll Rd, Toronto, ON M5S 3G8, Canada
[2] McGill Univ, Dept Mech Engn, 817 Sherbrooke St West, Montreal, PQ H3A 0C3, Canada
[3] McGill Univ, Dept Min & Mat Engn, 3610 Rue Univ, Montreal, PQ H3A 0C5, Canada
[4] McGill Univ, Dept Elect & Comp Engn, 3480 Rue Univ, Montreal, PQ H3A 0E9, Canada
[5] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
[6] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
基金
加拿大自然科学与工程研究理事会;
关键词
rolled-up microtube; plasma-enhanced chemical vapor deposition; optical cavity; whispering-gallery mode; chemical and biosensors; WHISPERING-GALLERY-MODES; OPTICAL MICROCAVITIES; NANOMEMBRANES; FABRICATION; STRAIN; FREQUENCY; PECVD; FILMS; TUBES;
D O I
10.1088/1361-6528/aad0b1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The microtubes made through rolling-up of strain-engineered nanomembranes have received growing research attention after their first invention due to the technology's high flexibility, integrability, and versatility. These rolled-up microtubes have been used for a variety of device applications including sensors, batteries and transistors, among others. This paper reports the development of highly sensitive whispering-gallery mode (WGM) chemical sensors based on rolled-up microtube optical microcavities (RUM-OCs). For the first time, such microcavities were batch fabricated through rolling-up of plasma-enhanced chemical vapor deposition (PECVD)-synthesized SiOx/SiNx bilayer nanomembranes, which have better optical properties than the conventional electron-beam-deposited SiO/SiO2 bilayers. Benefiting from the high refractive index (RI) of PECVD-deposited SiNx, our RUM-OC shows an enhanced quality factor of 880 that is much higher than that (50) of a SiO/SiO2 RUM-OC with the same dimensions. The developed RUM-OC is used for sensitive WGM solvent sensing, and demonstrate a limit of detection of 10(-4) refractive index unit (RIU), which is 10 times lower than that (10(-3) RIU) of a SiO/SiO2 RUM-OC.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Rolled-up nanomembranes as compact 3D architectures for field effect transistors and fluidic sensing applications
    Grimm, Daniel
    Bufon, Carlos Cesar Bof
    Deneke, Christoph
    Atkinson, Paola
    Thurmer, Dominic J.
    Schaeffel, Franziska
    Gorantla, Sandeep
    Bachmatiuk, Alicja
    Schmidt, Oliver G.
    NANO LETTERS, 2013, 13 (01) : 213 - 218
  • [42] Enhanced axial confinement in a monolithically integrated self-rolled-up SiNx vertical microring photonic coupler
    Yu, Xin
    Goddard, Lynford L.
    Li, Xiuling
    Chen, Xiaogang
    APPLIED PHYSICS LETTERS, 2016, 109 (11)
  • [43] Sharp whispering-gallery modes in rolled-up vertical SiO2 microcavities with quality factors exceeding 5000
    Boettner, Stefan
    Li, Shilong
    Trommer, Jens
    Kiravittaya, Suwit
    Schmidt, Oliver G.
    OPTICS LETTERS, 2012, 37 (24) : 5136 - 5138
  • [44] Local-Wetting-Induced Deformation of Rolled-Up Si/Si-Ge Nanomembranes: A Potential Route for Remote Chemical Sensing
    Yu, Minrui
    Huang, Minghuang
    Savage, Donald E.
    Lagally, Max G.
    Blick, Robert H.
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2011, 10 (01) : 21 - 25
  • [45] Noble Quality Assurance System for Volumetric Modulated Arc Therapy: Dose Evaluation in Rolled-Up/-Out Plane of Radiochromic Films
    Park, J.
    Lee, J.
    Choi, K.
    Lee, J.
    Suh, T.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [46] Gold nanoparticle-induced diameter reduction and enhanced Raman shift in self-rolled-up InGaAs/GaAs microtubes
    Wang, Xiankun
    Wang, Qi
    Chai, Zhaoer
    Mao, Guoming
    Liu, Hao
    Ren, Xiaomin
    NANOPHOTONICS AND MICRO/NANO OPTICS III, 2016, 10027
  • [47] Hierarchical ultrathin rolled-up Co(OH)(CO3)0.5 films assembled on Ni0.25Co0.75Sx nanosheets for enhanced supercapacitive performance
    Bai, Lu
    Fang, Fang
    Sun, Hongyu
    Yan, Xingxu
    Sun, Xiaoming
    Luo, Jun
    Zhu, Jing
    RSC ADVANCES, 2014, 4 (101) : 57458 - 57462
  • [48] Air-Mode Photonic Crystal Micro-Ring Resonator With Enhanced Quality Factor for Refractive Index Sensing
    Xu, Yameng
    Hu, Shubo
    Kong, Mei
    IEEE PHOTONICS JOURNAL, 2020, 12 (03):
  • [49] Enhanced Quality Factor of Polyvinyl formal (PVF) Based Nanocomposites Filled with Zinc Oxide and Carbon Black Nanoparticles for Wireless Sensing Applications
    Mohanapriya, M. K.
    Deshmukh, Kalim
    Sadasivuni, Kishor Kumar
    Thangamani, G.
    Chidambaram, K.
    Ahamed, M. Basheer
    Pasha, S. K. Khadheer
    MATERIALS TODAY-PROCEEDINGS, 2019, 9 : 199 - 216
  • [50] Highly sensitive label-free biosensor: graphene/CaF2 multilayer for gas, cancer, virus, and diabetes detection with enhanced quality factor and figure of merit
    Jafari, Behnam
    Gholizadeh, Elnaz
    Jafari, Bahram
    Zhoulideh, Moheimen
    Adibnia, Ehsan
    Ghafariasl, Mahdi
    Noori, Mohammad
    Golmohammadi, Saeed
    SCIENTIFIC REPORTS, 2023, 13 (01)