Reconstruction and navigation system for intraoperative brachytherapy using the flab technique for colorectal tumor bed irradiation

被引:10
|
作者
Strassmann, G
Walter, S
Kolotas, C
Heyd, R
Baltas, D
Debertshäuser, D
Nier, H
Tonus, C
Sakas, G
Zamboglou, N
机构
[1] Stadt Kliniken Offenbach, Strahlenklin, Dept Radiat Med, D-63069 Offenbach, Germany
[2] Fraunhoferinst, Inst Graph Datenverarbeitung, Darmstadt, Germany
[3] Natl Tech Univ Athens, Inst Commun & Comp Syst, Athens, Greece
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 47卷 / 05期
关键词
colorectal cancer; intraoperative HDR brachytherapy; treatment planning; navigation;
D O I
10.1016/S0360-3016(00)00492-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To present the development of a new navigation and reconstruction system based on an electromagnetic free-hand tracker and on CT imaging for treatment planning of intraoperative high-dose-rate brachytherapy (IORT-HDRB) in the sacral region. Our aim is to improve accuracy and to enable individualized treatment planning and dose documentation to be performed for IORT-HDRB using a flab technique. Methods and Materials: The material consists of an electromagnetic 3D tracker system, a PC workstation with Microsoft Windows NT 4.0 operating system, and a recognition program for continuous speech. In addition, we designed an external reference system constructed of titanium and Perspex, which is positioned in the pelvis, and a special digitizer pen for reconstruction of the flab geometry. The flab design incorporates a series of silicon 10-mm-diameter spherical pellets. Measurements were made with a pelvic phantom in order to study the accuracy of the system. The reconstruction results are stored and can be exported,ia network or floppy to our different treatment planning systems. Results: Our results for the reconstruction of a flab with six catheters and a total of 100 spherical pellets give mean errors in the range (2.5 +/- 0.6) mm to (3.5 +/- 0.8) mm depending on the positions of the pelvic phantom and transmitter relative to the operation table. These errors are calculated by comparing the reconstruction results of our system with those using a CT-based reconstruction of the flab geometry. For the accuracy of the navigation system for the pelvic phantom, we obtained mean errors in the range (2.2 +/- 0.7) mm to (3.1 +/- 1.0) mm, Conclusions: The new system we have developed enables navigation and reconstruction within the surgical environment with a clinically acceptable level of accuracy. It offers the possibility of individualized treatment planning and effective documentation of the 3D dose distribution in IORT-HDRB using a flab technique. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1323 / 1329
页数:7
相关论文
共 50 条
  • [31] Increased risk of late success with short interval between intraoperative tumor bed boost and mamma homogeneous irradiation
    Blank, E.
    Welzel, G.
    Keller, A.
    Hermann, B.
    Vorodi, F.
    Herskind, C.
    Tome, O.
    Suetterlin, M.
    Wenz, F.
    Kraus-Tiefenbacher, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 80 - 80
  • [32] Brain tumor enhancement revealed by 3D intraoperative ultrasound imaging in a navigation system
    Chalopin, C.
    Lindenberg, R.
    Arlt, F.
    Muens, A.
    Meixensberger, J.
    Lindner, D.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 468 - 471
  • [33] Navigation system based on intraoperative diffusion weighted imaging using open MRI
    Ozawa, N
    Muragaki, Y
    Shirakawa, H
    Suzukawa, H
    Nakamura, R
    Iseki, H
    CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 810 - 814
  • [34] Intraoperative functional MRI using a real-time neurosurgical navigation system
    Maldjian, JA
    Schulder, M
    Liu, MC
    Mun, IK
    Hirschorn, D
    Murthy, R
    Carmel, P
    Kalnin, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) : 910 - 912
  • [35] PERCUTANEOUS HIGH DOSE RATE (HDR) BRACHYTHERAPY OF AN OCCIPITAL SPINOCELLULAR CARCINOMA USING THE AFTER-LOADING TECHNIQUE WITH THE FREIBURG-FLAB APPLICATOR SET
    Schertler, A.
    Lippuner, T.
    Meier, U. R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 533 - 533
  • [36] Intraoperative evaluation of the anatomical double-bundle anterior cruciate ligament reconstruction with the OrthoPilot navigation system
    Ishibashi, Y
    Tsuda, E
    Tazawa, K
    Sato, H
    Toh, S
    ORTHOPEDICS, 2005, 28 (10) : S1277 - S1282
  • [37] Reduction of ipsilateral breast tumor recurrence rates by intraoperative radiotherapy boost technique and whole breast irradiation
    不详
    EJC SUPPLEMENTS, 2006, 4 (02): : 52 - 52
  • [38] Clinical Impact of Intraoperative Navigation Using a Doppler Ultrasonographic Guided Vessel Tracking Technique for Pancreaticoduodenectomy
    Maemura, Kosei
    Mataki, Yuko
    Kurahara, Hiroshi
    Iino, Satoshi
    Sakoda, Masahiko
    Ueno, Shinichi
    Shinchi, Hiroyuki
    Takao, Sonshin
    Natsugoe, Shoji
    INTERNATIONAL SURGERY, 2014, 99 (06) : 770 - 778
  • [39] Advanced Navigation System for Visionless Person using Pharos Technique
    Somasundaram, P. L.
    Ramya, R.
    Geetha, S.
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2019, 12 (03): : 14 - 17
  • [40] Intraoperative radiofrequency ablation using a 3D navigation tool for treatment of colorectal liver metastases
    Stippel, DL
    Böhm, S
    Beckurts, KTE
    Brochhagen, HG
    Hölscher, AH
    ONKOLOGIE, 2002, 25 (04): : 346 - 350