Cord blood collection and processing with hydroxyethyl starch or non-hydroxyethyl starch

被引:12
|
作者
Schwandt, Svenja [1 ]
Korschgen, Lutz [1 ]
Peters, Svenja [1 ]
Kogler, Gesine [1 ]
机构
[1] Univ Dusseldorf, Med Ctr, Inst Transplantat Diagnost & Cell Therapeut, Moorenstr 5, D-40225 Dusseldorf, Germany
关键词
AnnexinV; cord blood; processing; FLOW-CYTOMETRIC DETECTION; COLONY-FORMING-UNITS; PHOSPHATIDYLSERINE EXPRESSION; PEDIATRIC-PATIENTS; CD34(+) CELLS; SINGLE-CENTER; BONE-MARROW; ANNEXIN-V; TRANSPLANTATION; OUTCOMES;
D O I
10.1016/j.jcyt.2016.02.003
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Background. Collection and processing characteristics influencing quality of cord blood (CB) units play an essential role to cord blood banks (CBBs). At many CBBs, volume reduction is performed using hydroxyethyl starch (HES) and the Sepax (Biosafe) automated cell processing system. Due to the withdrawal of HES from the European market, a validation of the nonHES protocol was performed. Methods. This partially retrospective study identified CB characteristics such as gestational age and CB volume/cell count correlated with higher quality. For the nonHES validation, CB was analyzed for total nucleated cell (TNC), mononuclear cell (MNC) recovery, hematocrit (HCT) and colony-forming units (CFUs). Viabilities of CD34(+) and CD45(+) cells were determined by 7-aminoactinomycin D (7-AAD) and AnnexinV (AnnV) staining and compared for 21 mL and 42 mL buffy coat (BC) samples applying the HES/nonHES protocol. Results. Factors affecting the potency of CB transplants were the gestational age and the volume reduction to a defined BC volume. High initial cell counts and CB volumes correlated negatively with post-processing TNC recovery for lower BC volumes. Post-processing HES and nonHES results were comparable, but nonHES revealed a significantly lower post-thaw recovery of viable CD34+ cells measured by 7-AAD/AnnV (21 mL: 45.4 +/- 16.4%; 42 mL: 67.3 +/- 14.5%) as compared with HES (21 mL: 72.7 +/- 14.4%, P = 0.0164; 42 mL: 83.4 +/- 14.7%, P = 0.0203). Discussion. Due to the lower post-thaw CD34(+) cell viability (AnnV(-)/7-AAD(-)) for nonHES samples, the use of HES is recommended, ideally combined with a high BC volume. The post-processing HCT has no statistically significant impact on the post-thaw CD34(+) cell viability (AnnV(-)/7-AAD(-)).
引用
收藏
页码:642 / 652
页数:11
相关论文
共 50 条
  • [21] Pharmacokinetics of Hydroxyethyl Starch
    Cornelius Jungheinrich
    Thomas A. Neff
    Clinical Pharmacokinetics, 2005, 44 : 681 - 699
  • [22] Hydroxyethyl starch: Safe or not?
    Warren, BB
    Durieux, ME
    ANESTHESIA AND ANALGESIA, 1997, 84 (01): : 206 - 212
  • [23] HYDROXYETHYL STARCH IN CABG
    DIEHL, JT
    ANNALS OF THORACIC SURGERY, 1985, 39 (01): : 97 - 97
  • [24] Blood volume determination using hydroxyethyl starch
    Weil, MH
    CRITICAL CARE MEDICINE, 1997, 25 (04) : 566 - 566
  • [25] A BLOOD SUBSTITUTE FROM HYDROXYETHYL STARCH AND HEMOGLOBIN
    CERNY, LC
    CERNY, EL
    ROBACH, J
    REATH, M
    PONTERO, L
    ARTIFICIAL ORGANS, 1984, 8 (01) : 109 - 109
  • [26] INFLUENCE OF HYDROXYETHYL STARCH ON BLOOD-CLOTTING
    PETER, K
    GANDER, HP
    LUTZ, H
    NOLD, W
    STOSIEK, U
    ANAESTHESIST, 1975, 24 (05): : 219 - 224
  • [27] A BLOOD SUBSTITUTE FROM HYDROXYETHYL STARCH AND HEMOGLOBIN
    CERNY, LC
    CERNY, EL
    ROBACH, J
    REATH, M
    PONTERO, L
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 10 : 151 - 153
  • [28] Effect of hydroxyethyl starch on blood glucose levels
    Jung, Ki Tae
    Shim, Soo Bin
    Choi, Woo Young
    An, Tae Hun
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2016, 69 (04) : 350 - 356
  • [29] Effects of hydroxyethyl starch on blood coagulation profile
    Türkan, H
    Ural, AU
    Beyan, C
    Yalçin, A
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (03) : 156 - 159
  • [30] Influence of saline-based hydroxyethyl starch on umbilical cord blood electrolytes
    Yatabe, Tomoaki
    Nishigaki, Atsushi
    Tamura, Takahiko
    Yokoyama, Masataka
    JOURNAL OF ANESTHESIA, 2017, 31 (02) : 291 - 293