A non-enzymatic sensor for hydrogen peroxide based on the use of α-Fe2O3 nanoparticles deposited on the surface of NiO nanosheets

被引:46
|
作者
Achari, Divyalakshmi Saravana [1 ]
Santhosh, Chella [2 ]
Deivasegamani, Revathy [1 ]
Nivetha, Ravi [1 ]
Bhatnagar, Amit [2 ]
Jeong, Soon Kwan [3 ]
Grace, Andrews Nirmala [1 ]
机构
[1] VIT Univ, Ctr Nanotechnol Res, Vellore 632014, Tamil Nadu, India
[2] Univ Eastern Finland, Dept Environm & Biol Sci, POB 1627, FI-70211 Kuopio, Finland
[3] Korea Inst Energy Res, Green Energy Proc Lab, 152 Gajeong Ro, Daejeon 34129, South Korea
关键词
NiO/alpha-Fe2O3; Nanocomposites; Non-enzymatic sensor; H2O2; Amperometry; Electrocatalysis; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; BIOSENSOR; GRAPHENE; GLUCOSE; HEMOGLOBIN; NANOTUBES; IMMOBILIZATION; NANOWALLS; ALCOHOLS;
D O I
10.1007/s00604-017-2335-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the synthesis of nanocomposites from NiO and alpha-Fe2O3 by a hydrothermal route. The material was characterized in terms of structural and morphological features by X-ray diffraction and scanning electron microscopy. The nanocomposites were synthesized by growing alpha-Fe2O3 nanoparticles on the surface of flower-like NiO nanosheets, and then characterized by cyclic voltammetry and amperometric techniques. A glassy carbon electrode (GCE) modified with the nanocomposite displayed distinctly improved response to H2O2 compared to a GCE modified with bare NiO. The H2O2 sensor, best operated at a voltage of 0.4 V (vs. Ag/AgCl) has a sensitivity of 146.98 mu A.mu M-1.cm(-2), a 0.05 mM lower detection limit, and a linear working range that extends from 0.5 to 3 mM of H2O2. The sensor is reproducible and long-term stable even in the presence of various interfering molecules such as ascorbic acid and uric acid.
引用
收藏
页码:3223 / 3229
页数:7
相关论文
共 50 条
  • [31] Non-enzymatic amperometric sensor for hydrogen peroxide based on a biocomposite made from chitosan, hemoglobin, and silver nanoparticles
    Tian, Li
    Feng, Yongjia
    Qi, Yanjuan
    Wang, Binbin
    Chen, Yinran
    Fu, Xueyan
    MICROCHIMICA ACTA, 2012, 177 (1-2) : 39 - 45
  • [32] A non-enzymatic hydrogen peroxide sensor based on dendrimer functionalized magnetic graphene oxide decorated with palladium nanoparticles
    Baghayeri, Mehdi
    Alinezhad, Heshmatollah
    Tarahomi, Mehrasa
    Fayazi, Maryam
    Ghanei-Motlagh, Masoud
    Maleki, Behrooz
    APPLIED SURFACE SCIENCE, 2019, 478 : 87 - 93
  • [33] Flexible electrochemical sensor based on laser scribed Graphene/Ag nanoparticles for non-enzymatic hydrogen peroxide detection
    Aparicio-Martinez, Eider
    Ibarra, Adriana
    Estrada-Moreno, Ivan A.
    Osuna, Velia
    Dominguez, Rocio B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
  • [34] Heterostructure Fe2O3–In2O3 Nanoparticles as Hydrogen Gas Sensor
    D. M. Chethana
    T. C. Thanuja
    H. M. Mahesh
    M. S. Kiruba
    H. C. Barshilia
    S. Yallappa
    J. Manjanna
    Journal of Electronic Materials, 2021, 50 : 4313 - 4323
  • [35] A novel non-enzymatic hydrogen peroxide sensor based on poly-melamine film modified with platinum nanoparticles
    He, Sijing
    Chen, Zuanguang
    Yu, Yanyan
    Shi, Lijuan
    RSC ADVANCES, 2014, 4 (85): : 45185 - 45190
  • [36] A non-enzymatic amperometric hydrogen peroxide sensor based on iron nanoparticles decorated reduced graphene oxide nanocomposite
    Amanulla, Baishnisha
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Chiu, Te-Wei
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 487 : 370 - 377
  • [37] Surface modification of CuO nanoparticles with conducting polythiophene as a non-enzymatic amperometric sensor for sensitive and selective determination of hydrogen peroxide
    Rashed, Md. A.
    Ahmed, Jahir
    Faisal, M.
    Alsareii, S. A.
    Jalalah, Mohammed
    Tirth, Vineet
    Harraz, Farid A.
    SURFACES AND INTERFACES, 2022, 31
  • [38] Facile and Rapid Synthesis of Microwave Assisted Pd Nanoparticles as Non-Enzymatic Hydrogen Peroxide Sensor
    Sahin, Ozlem
    Kivrak, Hilal
    Kivrak, Arif
    Kazici, Hilal Celik
    Alal, Orhan
    Atbas, Dilan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (01): : 762 - 769
  • [39] Novel Fe@Fe-O@Ag nanocomposite for efficient non-enzymatic sensing of hydrogen peroxide
    Jakubec, Petr
    Urbanova, Veronika
    Markova, Zdenka
    Zboril, Radek
    ELECTROCHIMICA ACTA, 2015, 153 : 62 - 67
  • [40] α-Fe2O3 Film with Highly Photoactivity for Non-Enzymatic Photoelectrochemical Detection of Glucose
    Liu, Fuyan
    Wang, Peng
    Zhang, Qianqian
    Wang, Zeyan
    Liu, Yuanyuan
    Zheng, Zhaoke
    Qin, Xiaoyan
    Zhang, Xiaoyang
    Dai, Ying
    Huang, Baibiao
    ELECTROANALYSIS, 2019, 31 (09) : 1809 - 1814