A non-enzymatic sensor for hydrogen peroxide based on the use of α-Fe2O3 nanoparticles deposited on the surface of NiO nanosheets

被引:46
|
作者
Achari, Divyalakshmi Saravana [1 ]
Santhosh, Chella [2 ]
Deivasegamani, Revathy [1 ]
Nivetha, Ravi [1 ]
Bhatnagar, Amit [2 ]
Jeong, Soon Kwan [3 ]
Grace, Andrews Nirmala [1 ]
机构
[1] VIT Univ, Ctr Nanotechnol Res, Vellore 632014, Tamil Nadu, India
[2] Univ Eastern Finland, Dept Environm & Biol Sci, POB 1627, FI-70211 Kuopio, Finland
[3] Korea Inst Energy Res, Green Energy Proc Lab, 152 Gajeong Ro, Daejeon 34129, South Korea
关键词
NiO/alpha-Fe2O3; Nanocomposites; Non-enzymatic sensor; H2O2; Amperometry; Electrocatalysis; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; BIOSENSOR; GRAPHENE; GLUCOSE; HEMOGLOBIN; NANOTUBES; IMMOBILIZATION; NANOWALLS; ALCOHOLS;
D O I
10.1007/s00604-017-2335-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the synthesis of nanocomposites from NiO and alpha-Fe2O3 by a hydrothermal route. The material was characterized in terms of structural and morphological features by X-ray diffraction and scanning electron microscopy. The nanocomposites were synthesized by growing alpha-Fe2O3 nanoparticles on the surface of flower-like NiO nanosheets, and then characterized by cyclic voltammetry and amperometric techniques. A glassy carbon electrode (GCE) modified with the nanocomposite displayed distinctly improved response to H2O2 compared to a GCE modified with bare NiO. The H2O2 sensor, best operated at a voltage of 0.4 V (vs. Ag/AgCl) has a sensitivity of 146.98 mu A.mu M-1.cm(-2), a 0.05 mM lower detection limit, and a linear working range that extends from 0.5 to 3 mM of H2O2. The sensor is reproducible and long-term stable even in the presence of various interfering molecules such as ascorbic acid and uric acid.
引用
收藏
页码:3223 / 3229
页数:7
相关论文
共 50 条
  • [1] A non-enzymatic sensor for hydrogen peroxide based on the use of α-Fe2O3 nanoparticles deposited on the surface of NiO nanosheets
    Divyalakshmi Saravana achari
    Chella Santhosh
    Revathy Deivasegamani
    Ravi Nivetha
    Amit Bhatnagar
    Soon Kwan Jeong
    Andrews Nirmala Grace
    Microchimica Acta, 2017, 184 : 3223 - 3229
  • [2] A non-enzymatic hydrogen peroxide sensor based on vertical NiO nanosheets supported on the graphite sheet
    Liu, Wei
    Zhang, Hongxiu
    Yang, Bin
    Li, Zhongjian
    Lei, Lecheng
    Zhang, Xingwang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 749 : 62 - 67
  • [3] A Non-enzymatic Hydrogen Peroxide Sensor with Enhanced Sensitivity Based on Pt Nanoparticles
    Awais, Azka
    Arsalan, Muhammad
    Sheng, Qinglin
    Yue, Tianli
    ANALYTICAL SCIENCES, 2021, 37 (10) : 1419 - 1426
  • [4] A Non-enzymatic Hydrogen Peroxide Sensor with Enhanced Sensitivity Based on Pt Nanoparticles
    Azka Awais
    Muhammad Arsalan
    Qinglin Sheng
    Tianli Yue
    Analytical Sciences, 2021, 37 : 1419 - 1426
  • [5] A highly sensitive non-enzymatic hydrogen peroxide and hydrazine electrochemical sensor based on 3D micro-snowflake architectures of α-Fe2O3
    Majumder, S.
    Saha, B.
    Dey, S.
    Mondal, R.
    Kumar, S.
    Banerjee, S.
    RSC ADVANCES, 2016, 6 (65): : 59907 - 59918
  • [6] Development of a Non-Enzymatic Glucose Sensor Based on Fe2O3 Nanoparticles-Carbonve and Analytica Paste Electrodes
    Hernandez-Ramirez, D.
    Mendoza-Huizar, L. H.
    Galan-Vidal, C. A.
    Aguilar-Lira, G. Y.
    Alvarez-Romero, G. A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (06)
  • [7] Non-enzymatic hydrogen peroxide sensor based on Co3O4 nanocubes
    Cao, Guang Sheng
    Wang, Lei
    Yuan, Pengfei
    Gao, Chao
    Liu, Xiaojuan
    Li, Tong
    Li, Tianmin
    BULLETIN OF MATERIALS SCIENCE, 2014, 37 (06) : 1369 - 1373
  • [8] Non-enzymatic hydrogen peroxide sensor based on Co3O4 nanocubes
    Guang Sheng Cao
    Lei Wang
    Pengfei Yuan
    Chao Gao
    Xiaojuan Liu
    Tong Li
    Tianmin Li
    Bulletin of Materials Science, 2014, 37 : 1369 - 1373
  • [9] A novel non-enzymatic glucose sensor modified with Fe2O3 nanowire arrays
    Cao, Xia
    Wang, Ning
    ANALYST, 2011, 136 (20) : 4241 - 4246
  • [10] γ-Fe2O3 modified exfoliated graphite flexible paper based non-enzymatic glucose sensor
    Choudhary, Piyush
    Tiwari, Chandni
    Tiwari, Ajay
    Singh, Vijay K.
    Laha, Suvra S.
    Malhotra, Bansi D.
    Dixit, Ambesh
    MATERIALS LETTERS, 2024, 365