Serum MMP-7 in the Diagnosis of Biliary Atresia

被引:85
|
作者
Jiang, Jingying [1 ,2 ]
Wang, Junfeng [1 ,2 ]
Shen, Zhen [1 ,2 ]
Lu, Xuexin [1 ,2 ]
Chen, Gong [1 ,2 ]
Huang, Yanlei [1 ,2 ]
Dong, Rui [1 ,2 ]
Zheng, Shan [1 ,2 ]
机构
[1] Fudan Univ, Childrens Hosp, Dept Pediat Surg, Shanghai Key Lab Birth Defects, 399 Wan Yuan Rd, Shanghai 201102, Peoples R China
[2] Minist Hlth, Key Lab Neonatal Dis, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
KASAI PROCEDURE; NATIVE LIVER; FIBROSIS; PATHOGENESIS; EXPRESSION; MEDIATORS;
D O I
10.1542/peds.2019-0902
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BACKGROUND: The overlapping features of biliary atresia (BA) and other neonatal cholestasis with alternative causes (non-BA) have posed challenges for diagnosis. Matrix metalloproteinase-7 (MMP-7) has been reported to be promising in diagnosing BA. We aimed to validate the diagnostic accuracy of MMP-7 for BA in a large population sample. METHODS: We enrolled 288 patients with neonatal obstructive jaundice from March 2017 to October 2018. Serum MMP-7 levels were measured by using an enzyme-linked immunosorbent assay. Receiver operating characteristic curves were constructed, and decision curve analysis was done. A Pearson correlation coefficient test was conducted to assess the correlation between MMP-7 levels and other characteristics. RESULTS: The median serum MMP-7 levels were 38.89 ng/mL (interquartile range: 22.96-56.46) for the BA group and 4.4 ng/mL (interquartile range: 2.73-6.56) for the non-BA group (P < .001). The area under the receiver operating characteristic curve value was 0.9829 for MMP-7, and the sensitivity, specificity, positive predictive value, and negative predictive value were 95.19%, 93.07%, 97.27%, and 91.43%, respectively, at a cutoff value of 10.37 ng/mL. When MMP-7 was combined with gamma glutamyl transferase, the diagnostic accuracy was slightly improved without significance when compared with MMP-7 alone and had an area under the curve of 0.9880 (P = .08). Decision curve analysis also showed potential for MMP-7 to be used for clinical applications. A significant correlation was found with fibrosis stage from liver biopsy (R = 0.47; P < .001). CONCLUSIONS: MMP-7 demonstrated good accuracy in diagnosing BA and holds promise for future clinical application. Furthermore, its correlation with liver fibrosis indicated its potential use as a therapeutic target or prognostic biomarker. BA is a serious disorder with difficulty in accurate noninvasive diagnosis. This study validated the promising diagnostic accuracy of MMP-7 for BA.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Matrix metalloproteinases, MMP-7 and MMP-26, in plasma and serum of control and preeclamptic umbilical cord blood
    Galewska, Zofia
    Romanowicz, Lech
    Jaworski, Stefan
    Bankowski, Edward
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2010, 150 (02) : 152 - 156
  • [32] Serum periostin in biliary atresia
    Wiwanitkit, Somsri
    Wiwanitkit, Viroj
    BIOMARKERS, 2016, 21 (02) : 194 - 194
  • [33] High-throughput Proteomics Identifies MMP7 as a Biomarker of Biliary Atresia
    Lertudomphonwanit, Chatmanee
    Mourya, Reena
    Fei, Lin
    Zhang, Yue
    Bove, Kevin E.
    Shivakumar, Pranavkumar
    Bezerra, Jorge A.
    HEPATOLOGY, 2016, 64 : 68A - 69A
  • [34] Questioning Diagnostic Value of Serum Matrix Metalloproteinase 7 for Biliary Atresia
    Karbasian, Fereshteh
    Mashhadiagha, Amirali
    Anbardar, Mohammad H.
    Ataollahi, Maryam
    Dehghani, Seyed M.
    Honar, Naser
    Haghighat, Mahmood
    Imanieh, Mohammad H.
    Sayadi, Mehrab
    Shahramian, Iraj
    Aghsam, Ali
    Hosseini, Amirhossein
    Mortazavi, Seyedeh M. Mahadavi
    Darban, Behnaz
    Avazpour, Abbas
    Mirrahimi, Bahador
    Ruzbahani, Arian K.
    Tadayon, Ali
    JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2023, 13 (02) : 265 - 272
  • [35] SERUM MATRIX METALLOPROTEINASE-7 IN JAPANESE INFANTS WITH BILIARY ATRESIA
    Mizuochi, Tatsuki
    Sakaguchi, Hirotaka
    Konishi, Ken-Ichiro
    Yasuda, Ryosuke
    Kinoshita, Masahiro
    Fukahori, Suguru
    Shoji, Hiromichi
    Yoshimaru, Koichiro
    Matsuura, Toshiharu
    Sanada, Yukihiro
    Tainaka, Takahisa
    Uchida, Hiroo
    Sasaki, Hideyuki
    Iwama, Itaru
    Fujishiro, Jun
    Nio, Masaki
    HEPATOLOGY, 2021, 74 : 1178A - 1178A
  • [36] Diagnostic Accuracy of Serum Matrix Metalloproteinase-7 for Biliary Atresia
    Yang, Li
    Zhou, Ying
    Xu, Pei-pei
    Mourya, Reena
    Lei, Hai-yan
    Cao, Guo-qing
    Xiong, Xiao-li
    Xu, Hui
    Duan, Xu-fei
    Wang, Na
    Fei, Lin
    Chang, Xiao-pan
    Zhang, Xi
    Jiang, Meng
    Bezerra, Jorge A.
    Tang, Shao-tao
    HEPATOLOGY, 2018, 68 (06) : 2069 - 2077
  • [37] Diagnostic Accuracy of Serum Matrix Metalloproteinase-7 for Biliary Atresia
    Yang, Li
    Zhou, Ying
    Xu, Pei-Pei
    Mourya, Reena
    Lei, Hai-Yan
    Cao, Guo-Qing
    Xiong, Xiao-Li
    Xu, Hui
    Duan, Xu-Fei
    Wang, Na
    Fei, Lin
    Chang, Xiao-Pan
    Zhang, Xi
    Jiang, Meng
    Bezerra, Jorge A.
    Tang, Shao-Tao
    HEPATOLOGY, 2018, 68 : 118A - 118A
  • [38] Quantification of Serum Matrix Metallopeptide 7 Levels May Assist in the Diagnosis and Predict the Outcome for Patients with Biliary Atresia
    Wu, Jia-Feng
    Jeng, Yung-Ming
    Chen, Huey-Ling
    Ni, Yen-Hsuan
    Hsu, Hong-Yuan
    Chang, Mei-Hwei
    JOURNAL OF PEDIATRICS, 2019, 208 : 30 - +
  • [39] Biliary atresia: US diagnosis
    Humphrey, Terry M.
    Stringer, Mark D.
    RADIOLOGY, 2007, 244 (03) : 845 - 851
  • [40] MMP-7 and Cardiovascular Disease: Not So Surprising!
    Vanhoutte, Paul M.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2013, 112 (01) : 2 - 2