The application of convolution-based statistical model on the electrical breakdown time delay distributions in neon

被引:25
|
作者
Maluckov, CA
Karamarkovic, JP
Radovic, MK
Pejovic, MM
机构
[1] Univ Belgrade, Techn Fac Bor, YU-19210 Bor, Serbia
[2] Univ Nish, Fac Civil Engn & Architecture, YU-18000 Nish, Serbia
[3] Univ Nish, Fac Sci & Math, YU-18000 Nish, Serbia
[4] Univ Nish, Fac Elect Engn, YU-18000 Nish, Serbia
关键词
D O I
10.1063/1.1806478
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The convolution-based model of the electrical breakdown time delay distribution is applied for statistical analysis of experimental results obtained in neon-filled diode tube at 6.5 mbar. At first, the numerical breakdown time delay density distributions are obtained by stochastic modeling as the sum of two independent random variables, the electrical breakdown statistical time delay with exponential, and discharge formative time with Gaussian distribution. Then, the single characteristic breakdown time delay distribution is obtained as the convolution of these two random variables with previously determined parameters. These distributions show good correspondence with the experimental distributions, obtained on the basis of 1000 successive and independent measurements. The shape of distributions is investigated, and corresponding skewness and kurtosis are plotted, in order to follow the transition from Gaussian to exponential distribution. (C) 2004 American Institute of Physics.
引用
收藏
页码:5328 / 5334
页数:7
相关论文
共 50 条
  • [41] Separation of vacuum and gas breakdown processes in argon and their influence on electrical breakdown time delay
    Pejovic, Milic
    Pejovic, Momcilo
    Belic, Cedomir
    Starikovic, Koviljka
    VACUUM, 2020, 173
  • [42] Application of time delay method for analysis of processes which initiate electrical breakdown in 1.3 mbar nitrogen
    Univ of Nis, Serbia, Yugoslavia
    IEEE Trans Plasma Sci, 6 (1733-1737):
  • [43] The application of time delay method for analysis of processes which initiate electrical breakdown in 1.3 mbar nitrogen
    Pejovic, MM
    Karamarkovic, JP
    Ristic, GS
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1998, 26 (06) : 1733 - 1737
  • [44] A convolution-based distance measure for fuzzy singletons and its application in a pattern recognition problem
    Naranjo, Rodrigo
    Santos, Matilde
    Garmendia, Luis
    INTEGRATED COMPUTER-AIDED ENGINEERING, 2021, 28 (01) : 51 - 63
  • [45] Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices
    Pejovic, Milic M.
    Denic, Dragan B.
    Pejovic, Momcilo M.
    Nesic, Nikola T.
    Vasovic, Nikola
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [46] CONVOLUTION-BASED ATTENTION MODEL WITH POSITIONAL ENCODING FOR STREAMING SPEECH RECOGNITION ON EMBEDDED DEVICES
    Park, Jinhwan
    Kim, Chanwoo
    Sung, Wonyong
    2021 IEEE SPOKEN LANGUAGE TECHNOLOGY WORKSHOP (SLT), 2021, : 30 - 37
  • [47] 3D Convolution-Based Video Compression Model Without Motion Estimation
    Guangdong Key Laboratory of Intelligent Information Processing, College of Electronic and Information Engineering, Shenzhen University, China
    Proc SPIE Int Soc Opt Eng,
  • [48] Experimental investigation of breakdown voltage and electrical breakdown time delay of commercial gas discharge tubes
    Pejović, Milić Momčilo
    Pejović, Momčilo Milić
    Stanković, Koviljka
    Japanese Journal of Applied Physics, 2011, 50 (8 PART 1):
  • [49] Experimental Results of Breakdown Voltage and Electrical Breakdown Time Delay of Geiger-Muller Chamber
    Pejovic, Milic M.
    2022 57TH INTERNATIONAL SCIENTIFIC CONFERENCE ON INFORMATION, COMMUNICATION AND ENERGY SYSTEMS AND TECHNOLOGIES (ICEST), 2022, : 330 - 333
  • [50] Experimental Investigation of Breakdown Voltage and Electrical Breakdown Time Delay of Commercial Gas Discharge Tubes
    Pejovic, Milic Momcilo
    Pejovic, Momcilo Milic
    Stankovic, Koviljka