Coronary CT Angiography with Photon-counting CT: First-In-Human Results

被引:177
|
作者
Si-Mohamed, Salim A. [1 ,2 ]
Boccalini, Sara [1 ,2 ]
Lacombe, Hugo [1 ]
Diaw, Adja [1 ]
Varasteh, Mohammad [1 ]
Rodesch, Pierre-Antoine [1 ]
Dessouky, Riham [4 ]
Villien, Marjorie [5 ]
Tatard-Leitman, Valerie [1 ]
Bochaton, Thomas [3 ]
Coulon, Philippe [5 ]
Yagil, Yoad [6 ]
Lahoud, Elias [6 ]
Erhard, Klaus [7 ]
Riche, Benjamin [8 ,9 ]
Bonnefoy, Eric [3 ]
Rioufol, Gilles [3 ]
Finet, Gerard [3 ]
Bergerot, Cyrille [3 ]
Boussel, Loic [1 ,2 ]
Greffier, Joel [10 ]
Douek, Philippe C. [1 ,2 ]
机构
[1] Univ Lyon, INSA Lyon, Univ Claude Bernard Lyon 1, UJM St Etienne,CNRS,Inserm,CREATIS UMR 5220,U1206, Villeurbanne, France
[2] Hosp Civils Lyon, Louis Pradel Hosp, Dept Radiol, Bron, France
[3] Hosp Civils Lyon, Louis Pradel Hosp, Dept Cardiol, Bron, France
[4] Zagazig Univ, Fac Med, Dept Radiol, Zagazig, Egypt
[5] Philips Healthcare, Suresnes, France
[6] Philips Healthcare, Haifa, Israel
[7] Philips Healthcare, Hamburg, Germany
[8] Hosp Civils Lyon, Dept Biostat & Bioinformat, Publ Hlth Canter, Lyon, France
[9] CNRS, Biostat Hlth Team, Dept Biometr & Evolutionary Biol Lab, UMR 5558, Villeurbanne, France
[10] Univ Montpellier, Dept Med Imaging, CIIU Nimes, Nimes Med Imaging Grp,EA 2992, Montpellier, France
关键词
COMPUTED TOMOGRAPHIC ANGIOGRAPHY; SCCT GUIDELINES; FEASIBILITY; PERFORMANCE; SOCIETY;
D O I
10.1148/radiol.211780
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background. Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose: To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating -detector (EID) dual-layer CT (DLCT) system. Materials and Methods: In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results: Fourteen consecutive participants (12 men; mean age, 61 years 6 17) were enrolled. Scores of overall quality and -diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs 6 0 versus 349 mAs 6 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion: Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. (C) RSNA, 2022 Online supplemental material is available for this article.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Coronary artery disease detection using deep learning and ultrahigh-resolution photon-counting coronary CT angiography
    Brendel, Jan M.
    Walterspiel, Jonathan
    Hagen, Florian
    Kuebler, Jens
    Brendlin, Andreas S.
    Afat, Saif
    Paul, Jean-Francois
    Kuestner, Thomas
    Nikolaou, Konstantin
    Gawaz, Meinrad
    Greulich, Simon
    Krumm, Patrick
    Winkelmann, Moritz T.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2025, 106 (02) : 68 - 75
  • [32] Photon-counting CT: A Step Change Leading to a Revolution in Coronary Imaging
    Williams, Michelle C.
    Newby, David E.
    RADIOLOGY, 2023, 307 (05)
  • [33] Reclassification of Coronary Artery Disease Status Using Photon-counting CT
    McCollough, Cynthia H.
    RADIOLOGY, 2024, 310 (02)
  • [34] The Photon-Counting CT Enters the Field of Cochlear Implantation: Comparison to Angiography DynaCT and Conventional Multislice CT
    Rak, Kristen
    Spahn, Bjoern
    Mueller-Graff, Franz-Tassilo
    Engert, Jonas
    Voelker, Johannes
    Hackenberg, Stephan
    Hagen, Rudolf
    Petritsch, Bernhard
    Grunz, Jan-Peter
    Bley, Thorsten
    Neun, Tilmann
    Huflage, Henner
    OTOLOGY & NEUROTOLOGY, 2024, 45 (06) : 662 - 670
  • [35] An introduction to photon-counting detector CT (PCD CT) for radiologists
    Nakamura, Yuko
    Higaki, Toru
    Kondo, Shota
    Kawashita, Ikuo
    Takahashi, Isao
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (03) : 266 - 282
  • [36] An introduction to photon-counting detector CT (PCD CT) for radiologists
    Yuko Nakamura
    Toru Higaki
    Shota Kondo
    Ikuo Kawashita
    Isao Takahashi
    Kazuo Awai
    Japanese Journal of Radiology, 2023, 41 : 266 - 282
  • [37] Thin slice photon-counting CT coronary angiography compared to conventional CT: Objective image quality and clinical radiation dose assessment
    van der Bie, Judith
    Bos, Daniel
    Dijkshoorn, Marcel L.
    Booij, Ronald
    Budde, Ricardo P. J.
    van Straten, Marcel
    MEDICAL PHYSICS, 2024, 51 (04) : 2924 - 2932
  • [38] Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer
    Rotzinger, David C.
    Racine, Damien
    Becce, Fabio
    Lahoud, Elias
    Erhard, Klaus
    Si-Mohamed, Salim A.
    Greffier, Joel
    Viry, Anais
    Boussel, Loic
    Meuli, Reto A.
    Yagil, Yoad
    Monnin, Pascal
    Douek, Philippe C.
    DIAGNOSTICS, 2021, 11 (12)
  • [39] First Clinical Photon-counting Detector CT System: Technical Evaluation
    Rajendran, Kishore
    Petersilka, Martin
    Henning, Andre
    Shanblatt, Elisabeth R.
    Schmidt, Bernhard
    Flohr, Thomas G.
    Ferrero, Andrea
    Baffour, Francis
    Diehn, Felix E.
    Yu, Lifeng
    Rajiah, Prabhakar
    Fletcher, Joel G.
    Leng, Shuai
    McCollough, Cynthia H.
    RADIOLOGY, 2022, 303 (01) : 130 - 138
  • [40] Photon-counting detector CT - first experiences in the field of musculoskeletal radiology
    Bette, Stefanie
    Risch, Franka
    Becker, Judith
    Popp, Daniel
    Decker, Josua A.
    Kaufmann, David
    Friedrich, Lena
    Scheurig-Muenkler, Christian
    Schwarz, Florian
    Kroencke, Thomas J.