The application of a simplified framework for the treatment of left breast cancer using deep inspiration breath-hold (DIBH) for reduced heart dose

被引:0
|
作者
Guan, H. [1 ]
Hammond, R. [1 ]
Pradhan, D. [1 ]
机构
[1] Henry Ford Hlth Syst, Detroit, MI USA
关键词
D O I
10.1118/1.2761125
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A simplified framework for deep inspiration breath‐hold (DIBH) was developed and used for patient simulation. This report presents the details of using the framework for left breast patient treatment. Materials and methods: For each patient, two plans were made, one with the free breathing CT and the other with the DIBH CT. Organ structures (left breast, heart and left lung) were contoured separately on each set of CT. Dose volume histograms (DVH) and dose statistics were used for comparison. Before treatment, the framework was set to patient in the same way as for simulation. Patient setup was made at DIBH such that P point's SSD (anterior) matches that from the simulation DIBH CT. Portal images were taken at DIBH and compared to DRRs generated from the DIBH CT for setup. Because the RPM inside the treatment room and that inside the simulation room had different setups, in case the DIBH amplitudes were different, the two gating threshold lines can be shifted and overlaid to the captured DIBH signal before treatment. The RPM system can guide the linac to turn on or off the radiation automatically. Results: Comparing the two plans based on two CT sets, it was found that the left breast dose coverage was similar. While the absolute DVH for left lung was higher with DIBH, the relative DVH was similar or even lower because of the much enlarged lung volume. The heart volume did not change much but the dose was appreciably reduced. One breath hold was generally enough for the treatment of each beam. We did find that the DIBH portal images matched better to DRRs generated from DIBH CT than with free breathing CT. Conclusion: The framework was successfully applied for the treatment of three left breast patients with reduced heart dose. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2493 / 2494
页数:2
相关论文
共 50 条
  • [41] Heart dose variability in RT of left breast cancer patients treated in deep inspiration breath hold
    Johansson, G.
    Freden, E.
    Knutsson, J.
    Olin, M.
    Dagertun, L.
    Siegbahn, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1255 - S1256
  • [42] Reproducibility of deep inspiration breath-hold and dosimetric implications in treatments of left-breast cancer
    Porcu, P.
    Fassi, A.
    Tabarelli, P.
    Liotta, M.
    Meaglia, I.
    Bocci, C.
    Riboldi, M.
    Baroni, G.
    Ivaldi, G. B.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S187 - S187
  • [43] Predictors of Cardiac Sparing in Deep Inspiration Breath-Hold for Patients With Left Sided Breast Cancer
    Mkanna, Abbas
    Mohamad, Osama
    Ramia, Paul
    Thebian, Ranim
    Makki, Maha
    Tamim, Hani
    Jalbout, Wassim
    Youssef, Bassem
    Eid, Toufic
    Geara, Fady
    Shahine, Bilal
    Zeidan, Youssef H.
    FRONTIERS IN ONCOLOGY, 2018, 8
  • [44] Deep inspiration breath-hold (DIBH) technique applied in right breast radiotherapy to minimize liver radiation
    Rice, L.
    Harris, S.
    Green, M. M. L.
    Price, P. M.
    BJR CASE REPORTS, 2015, 1 (02):
  • [45] Selection of patients with left breast cancer for Deep-Inspiration Breath-Hold Radiotherapy Technique
    Czeremszynska, B.
    Drozda, S.
    Gorzynski, M.
    Kepka, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S555 - S555
  • [46] Dose Sparing Potential of Deep Inspiration Breath-hold Technique for Left Breast Cancer Radiotherapy Organs-at-risk
    Lawler, Gavin
    Leech, Michelle
    ANTICANCER RESEARCH, 2017, 37 (02) : 883 - 890
  • [47] The DIBH (Deep Inspiration Breath-Hold) Monitoring Development Using Ultrasonic and IR Sensors with a Microcontroller
    Kwag, J. H.
    Lindsey, M.
    Hogan, T.
    Hinton, B.
    Reed, W. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E566 - E567
  • [48] Cardiac dose-sparing effects of deep-inspiration breath-hold in left breast irradiation
    Sakka, Mazen
    Kunzelmann, Leonie
    Metzger, Martin
    Grabenbauer, Gerhard G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 (10) : 800 - 811
  • [49] Titulo * Deep-inspiration-breath-hold (DIBH) radiotherapy in patients with left-sided breast cancer
    de la Fuente Alonso, C.
    Gil Haro, B.
    Velasco, J.
    Lopez, M.
    Benlloch, R.
    Zapata, I.
    Cordoba, S.
    Hernandez, M.
    Rodriguez, R.
    Sarrion, P.
    Santana, S.
    Perez, S.
    Martinez, F. J.
    Romero, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1022 - S1023
  • [50] Interim Report from the SAVE HEART Study: deep inspiration breath-hold in left-sided breast cancer
    Schoenecker, S.
    Gaasch, A.
    Pazos, M.
    Reitz, D.
    Braun, M.
    Harbeck, N.
    Freislederer, P.
    Niyazi, M.
    Belka, C.
    Corradini, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S88 - S88