First-pass myocardial perfusion cardiovascular magnetic resonance at 3 Tesla

被引:20
|
作者
Su, Mao-Yuan M.
Yang, Kai-Chien
Wu, Chau-Chung
Wu, Yen-Wen
Yu, Hsi-Yu
Tseng, Rung-Yu
Tseng, Wen-Yih I.
机构
[1] Natl Taiwan Univ, Ctr Optoelect Biomed, Coll Med, Taipei 10016, Taiwan
[2] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei 100, Taiwan
[4] Natl Taiwan Univ Hosp, Dept Nucl Med, Taipei, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Surg, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Med Imaging, Taipei, Taiwan
关键词
myocardial perfusion; 3; Tesla; ischemic heart disease;
D O I
10.1080/10976640601093661
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To test the feasibility of first-pass contrast-enhanced myocardial perfusion imaging at 3 Tesla and to evaluate the change in perfusion index between normal, remote and ischemic myocardium, we obtained perfusion index from healthy subjects and patients with coronary artery stenosis. Materials and Methods: First-pass contrast-enhanced perfusion imaging was performed on 12 patients and 32 age-matched healthy subjects in both rest and dipyridamole-induced stress states. After bolus injection of contrast agent, Gd-DTPA with dose of 0.025 mmol/kg body weight and injection time of 1.5 s, three short-axis images from apex to base of the left ventricle (LV) were acquired for 80 cardiac cycles using saturation recovery turbo FLASH sequence. The maximal upslope (Upslope) was derived from the signal-time curves of the LV cavity and myocardium to measure myocardial perfusion. Within 72 hours after cardiovascular magnetic resonance examination, patients received coronary angiography, and the results were correlated with cardiovascular magnetic resonance results. Results: Using our protocol of contrast agent administration, sufficient perfusion contrast was obtained without susceptibility-induced signal drop-out at the interface between LV cavity and the myocardium. In healthy volunteers, Upslope showed no dependence on myocardial segments or coronary territories. Upslope increased significantly from rest to stress in normal myocardium (0.09 +/- 0.03 vs. 0.16 +/- 0.05, p < 0.001) and remote myocardium (0.09 +/- 0.03 vs. 0.13 +/- 0.03, p < 0.001), whereas in ischemic myocardium the change was insignificant (0.11 +/- 0.03 vs. 0.10 +/- 0.04, p = ns). This resulted in significant difference in the ratio of Upslope at stress to that at rest, representing myocardial perfusion reserve, between ischemic and non-ischemic myocardium (0.96 +/- 0.41 vs. 1.71 +/- 0.42, p < 0.001 for ischemic vs. normal myocardium; 0.96 +/- 0.41 vs. 1.59 +/- 0.40, p < 0.001 for ischemic vs. remote myocardium). Conclusions: First-pass gadolinium-enhanced myocardial perfusion imaging at 3 Tesla is feasible. The Upslope ratio can differentiate ischemic from non-ischemic myocardium.
引用
收藏
页码:633 / 644
页数:12
相关论文
共 50 条
  • [21] Myocardial first-pass perfusion magnetic resonance imaging - A multicenter dose-ranging study
    Wolff, SD
    Schwitter, J
    Coulden, R
    Friedrich, MG
    Bluemke, DA
    Biederman, RW
    Martin, ET
    Lansky, AJ
    Kashanian, F
    Foo, TKF
    Licato, PE
    Comeau, CR
    CIRCULATION, 2004, 110 (06) : 732 - 737
  • [22] First-pass Perfusion Defect of the Subendocardium by Cardiac Magnetic Resonance Indicates the Microvascular Myocardial Ischemia
    Shinagawa, Hisahito
    Inomata, Takayuki
    Iwamoto, Miwa
    Ishii, Shunsuke
    Watanabe, Ichiro
    Koitabashi, Toshimi
    Nishii, Mototsugu
    Takeuchi, Ichiro
    Izumi, Tohru
    JOURNAL OF CARDIAC FAILURE, 2011, 17 (09) : S165 - S166
  • [23] Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients
    Milidonis, Xenios
    Nazir, Muhummad Sohaib
    Schneider, Torben
    Capstick, Myles
    Drost, Sita
    Kok, Gertjan
    Pelevic, Nikola
    Poelma, Christian
    Schaeffter, Tobias
    Chiribiri, Amedeo
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2871 - 2884
  • [24] Quantitative myocardial first-pass cardiovascular magnetic resonance perfusion imaging using hyperpolarized [1-13C] pyruvate
    Fuetterer, Maximilian
    Busch, Julia
    Traechtler, Julia
    Wespi, Patrick
    Peereboom, Sophie M.
    Sauer, Mareike
    Lipiski, Miriam
    Fleischmann, Thea
    Cesarovic, Nikola
    Stoeck, Christian T.
    Kozerke, Sebastian
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [25] Assessment of coronary microvascular dysfunction in hypertrophic cardiomyopathy: First-pass myocardial perfusion cardiovascular magnetic resonance imaging at 1.5 T
    Huang, L.
    Han, R.
    Ai, T.
    Sun, Z.
    Bai, Y.
    Cao, Z.
    Morelli, J. N.
    Xia, L.
    CLINICAL RADIOLOGY, 2013, 68 (07) : 676 - 682
  • [26] Quantitative myocardial first-pass cardiovascular magnetic resonance perfusion imaging using hyperpolarized [1-13C] pyruvate
    Maximilian Fuetterer
    Julia Busch
    Julia Traechtler
    Patrick Wespi
    Sophie M. Peereboom
    Mareike Sauer
    Miriam Lipiski
    Thea Fleischmann
    Nikola Cesarovic
    Christian T. Stoeck
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 20
  • [27] Sensitivity of resting magnetic resonance first-pass myocardial perfusion imaging for the detection of acute and chronic myocardial infarction
    Alejandro Aquino
    Edwin Wu
    Thomas A Holly
    Daniel C Lee
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [28] Steady-state first-pass perfusion (SSFPP): A 3D TWIST in myocardial first-pass perfusion imaging
    Shivraman Giri
    Hui Xue
    Abdul Wattar
    Yu Ding
    Randall M Kroeker
    Gerhard Laub
    Peter Kellman
    Sven Zuehlsdorff
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [29] Parallel imaging for first-pass myocardial perfusion
    Irwan, Roy
    Lubbers, Daniel D.
    van der Vleuten, Pieter A.
    Kappert, Peter
    Gotte, Marco J. W.
    Sijens, Paul E.
    MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 678 - 683
  • [30] 2004 3D first-pass myocardial perfusion imaging with complete left ventricular coverage at 3 Tesla
    Taehoon Shin
    Houchun H Hu
    Samuel S Valencerina
    Luis Martinez
    Gerald M Pohost
    Krishna S Nayak
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)