Comparison of Iodixanol and Ioxaglate for Coronary Optical Coherence Tomography Imaging

被引:0
|
作者
Christakopoulos, Georgios E.
Kotsia, Anna P.
Christopoulos, Georgios
Abdullah, Shuaib M.
Rangan, Bavana V.
Roesle, Michele
Banerjee, Subhash
Brilakis, Emmanouil S.
机构
[1] VA North Texas Hlth Care Syst, Dallas, TX USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2015年 / 27卷 / 12期
关键词
coronary artery disease; cardiac imaging; radiographic contrast; iodixanol; ioxaglate; MOLECULAR-WEIGHT DEXTRAN; INTRAVASCULAR ULTRASOUND; CONTRAST-MEDIA; ATHEROSCLEROSIS; OCCLUSION; PLAQUE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The impact of contrast type on coronary imaging using optical coherence tomography (OCT) has received limited study. We compared OCT imaging obtained using the non-ionic, iso-osmolar iodixanol with the ionic, low-osmolar ioxaglate. Methods. Twenty-two vessels in 20 patients were imaged twice using manual injection of iodixanol and ioxaglate in random order. OCT images were analyzed at 1 mm intervals to determine lumen area, artifact diameter and area, as well as stent strut coverage and malapposition in OCT pullbacks that included stents. Results. There were no complications related to OCT imaging or to contrast administration. A total of 2184 cross-sections (1092 with iodixanol and 1092 with ioxaglate) were analyzed. Compared with iodixanol, imaging using ioxaglate provided similar mean lumen area (6.21 +/- 2.83 mm(2) vs 6.27 +/- 2.83 mm(2); Spearman's rho, 0.982), mean minimum lumen diameter (2.47 +/- 0.59 mm vs 2.50 +/- 0.58 mm; Spearman's rho, 0.939), and mean maximum lumen diameter (2.99 +/- 0.71 mm vs 3.01 +/- 0.70 mm; Spearman's rho, 0.964), but lower mean artifact area per cross-section (0.099 +/- 0.325 mm(2) vs 0.068 +/- 0.329 mm(2); P<.001). Analyses of 3303 stent struts in 388 cross-sections (194 with iodixanol and 194 with ioxaglate) demonstrated similar strut malapposition rates (11.82% vs 13.90%; P=.10) and strut coverage (41.92% vs 40.33%; P=.35). Conclusions. Compared with iodixanol, OCT imaging using ioxaglate provided similar lumen and diameter measurements and stent strut characterization, but smaller area of artifact.
引用
收藏
页码:E287 / E290
页数:4
相关论文
共 50 条
  • [21] Contribution of optical coherence tomography imaging in management of iatrogenic coronary dissection
    Barber-Chamoux, Nicolas
    Souteyrand, Geraud
    Combaret, Nicolas
    Ouedraogo, Edgar
    Lusson, Jean Rene
    Motreff, Pascal
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2016, 17 (02) : 138 - 142
  • [22] Spontaneous coronary dissection extension induced by optical coherence tomography imaging
    Garcia-Guimaraes, Marcos
    De Rueda, Clemencia
    Antuna, Paula
    Cuesta, Javier
    Bastante, Teresa
    Alfonso, Fernando
    REC-INTERVENTIONAL CARDIOLOGY, 2020, 2 (02): : 155 - 156
  • [23] In vivo optical coherence tomography imaging and histopathology of healed coronary plaques
    Shimokado, Aiko
    Matsuo, Yoshiki
    Kubo, Takashi
    Nishiguchi, Tsuyoshi
    Taruya, Akira
    Teraguchi, Ikuko
    Shiono, Yasutsugu
    Orii, Makoto
    Tanimoto, Takashi
    Yamano, Takashi
    Ino, Yasushi
    Hozumi, Takeshi
    Tanaka, Atsushi
    Muragaki, Yasuteru
    Akasaka, Takashi
    ATHEROSCLEROSIS, 2018, 275 : 35 - 42
  • [24] Optical coherence tomography of coronary arteries - a novel intravascular imaging modality
    Mrevlje, B.
    Legutko, J.
    Jakala, J.
    Noc, M.
    Dudek, D.
    Birkemeyer, R.
    Aboukoura, M.
    Nienaber, C.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2014, 139 (39) : 1941 - 1946
  • [25] Atherosclerotic Plaque Characterization by Coronary Computed Tomography Angiography: Comparison With Optical Coherence Tomography
    Li, Guanyu
    Li, Zehang
    Chen, Yankai
    Chu, Miao
    Li, Chunming
    Wang, Zhiqing
    Yan, Yuanming
    Luo, Yukun
    Cai, Wei
    Chen, Lianglong
    Tu, Shengxian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B185 - B185
  • [26] Optical Coherence Tomography of Coronary Arteries
    Roland, Robert
    Veselka, Josef
    INTERNATIONAL JOURNAL OF ANGIOLOGY, 2021, 30 (01) : 29 - 39
  • [27] Comparison between Iodixanol (Visipaque®) and Ioxaglate (Hexabrix®) for coronary angiography and ventriculography:: a double-blinded randomized study
    Roriz, R
    de Gevigney, G
    Finet, G
    Nantois-Collet, C
    Borch, KW
    Amiel, M
    Beaune, J
    JOURNAL DE RADIOLOGIE, 1999, 80 (07): : 727 - 732
  • [28] Comparison of an occlusive versus non-occlusive flush technique for imaging coronary arteries with optical coherence tomography
    Barlis, P.
    Del Furia, F.
    Dimopoulos, K.
    Ferrante, G.
    Tanigawa, J.
    D'Souza, S.
    Aguiar-Souto, P.
    Di Mario, C.
    EUROPEAN HEART JOURNAL, 2008, 29 : 849 - 849
  • [29] Optical coherence tomography and optical coherence tomography angiography imaging in Bietti crystalline dystrophy
    Tiryaki Demir, Semra
    Keles Yesiltas, Sumeyra
    Kacar, Hakan
    Akbas, Emine Betul
    Guven, Dilek
    OPHTHALMIC GENETICS, 2020, 41 (02) : 194 - 197
  • [30] In vivo macrophage Imaging of acute coronary syndromes with intracoronary optical coherence tomography
    MacNeill, BD
    Jang, IK
    Bouma, BE
    Iftimia, N
    Takano, M
    Yabushita, H
    Shishkov, M
    Tearney, GJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 33A - 33A