Comparison of Iodixanol and Ioxaglate for Coronary Optical Coherence Tomography Imaging

被引:0
|
作者
Christakopoulos, Georgios E.
Kotsia, Anna P.
Christopoulos, Georgios
Abdullah, Shuaib M.
Rangan, Bavana V.
Roesle, Michele
Banerjee, Subhash
Brilakis, Emmanouil S.
机构
[1] VA North Texas Hlth Care Syst, Dallas, TX USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2015年 / 27卷 / 12期
关键词
coronary artery disease; cardiac imaging; radiographic contrast; iodixanol; ioxaglate; MOLECULAR-WEIGHT DEXTRAN; INTRAVASCULAR ULTRASOUND; CONTRAST-MEDIA; ATHEROSCLEROSIS; OCCLUSION; PLAQUE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The impact of contrast type on coronary imaging using optical coherence tomography (OCT) has received limited study. We compared OCT imaging obtained using the non-ionic, iso-osmolar iodixanol with the ionic, low-osmolar ioxaglate. Methods. Twenty-two vessels in 20 patients were imaged twice using manual injection of iodixanol and ioxaglate in random order. OCT images were analyzed at 1 mm intervals to determine lumen area, artifact diameter and area, as well as stent strut coverage and malapposition in OCT pullbacks that included stents. Results. There were no complications related to OCT imaging or to contrast administration. A total of 2184 cross-sections (1092 with iodixanol and 1092 with ioxaglate) were analyzed. Compared with iodixanol, imaging using ioxaglate provided similar mean lumen area (6.21 +/- 2.83 mm(2) vs 6.27 +/- 2.83 mm(2); Spearman's rho, 0.982), mean minimum lumen diameter (2.47 +/- 0.59 mm vs 2.50 +/- 0.58 mm; Spearman's rho, 0.939), and mean maximum lumen diameter (2.99 +/- 0.71 mm vs 3.01 +/- 0.70 mm; Spearman's rho, 0.964), but lower mean artifact area per cross-section (0.099 +/- 0.325 mm(2) vs 0.068 +/- 0.329 mm(2); P<.001). Analyses of 3303 stent struts in 388 cross-sections (194 with iodixanol and 194 with ioxaglate) demonstrated similar strut malapposition rates (11.82% vs 13.90%; P=.10) and strut coverage (41.92% vs 40.33%; P=.35). Conclusions. Compared with iodixanol, OCT imaging using ioxaglate provided similar lumen and diameter measurements and stent strut characterization, but smaller area of artifact.
引用
收藏
页码:E287 / E290
页数:4
相关论文
共 50 条
  • [1] Evaluation and comparison between visipaque (iodixanol) and hexabrix (ioxaglate) in coronary angiography
    Persson, Pontus
    Liss, Per
    Hansell, Peter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (15) : 1668 - 1669
  • [2] Iodixanol and ioxaglate in percutaneous transluminal coronary angioplasty
    Bertrand, ME
    Esplugas, E
    Plessens, J
    CIRCULATION, 1998, 98 (17) : 87 - 88
  • [3] Evaluation and comparison between visipaque (iodixanol) and hexabrix (ioxaglate) in coronary angiography - Reply
    Jo, Sang-Ho
    Koo, Bon-Kwon
    Youn, Tae-Jin
    Kim, Hyo-Soo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (15) : 1669 - 1670
  • [4] Micro Optical Coherence Tomography for Coronary Imaging
    Nishimiya, Kensuke
    Tearney, Guillermo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [5] Immediate and late adverse reactions in coronary angiography. A comparison between iodixanol and ioxaglate
    Fransson, SG
    Stenport, G
    Andersson, M
    ACTA RADIOLOGICA, 1996, 37 (02) : 218 - 222
  • [6] Imaging and characterization of coronary lesions with optical coherence tomography
    Schmitt, JM
    Petersen, CL
    Mont, E
    Virmani, R
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 106 - 109
  • [7] Optical Coherence Tomography Imaging in Acute Coronary Syndromes
    Kubo, Takashi
    Ino, Yasushi
    Tanimoto, Takashi
    Kitabata, Hironori
    Tanaka, Atsushi
    Akasaka, Takashi
    CARDIOLOGY RESEARCH AND PRACTICE, 2011, 2011
  • [8] Optical Coherence Tomography Imaging of Takayasu Coronary Arteritis
    Amsallem, Myriam
    Henry, Patrick
    Silberman, Stephane Manzo
    CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (04) : 464.e13 - 464.e14
  • [9] Porcine coronary imaging in vivo by optical coherence tomography
    Tearney, GJ
    Jang, IK
    Kang, DH
    Aretz, HT
    Houser, SL
    Brady, TJ
    Schlendorf, K
    Shishkov, M
    Bouma, BE
    ACTA CARDIOLOGICA, 2000, 55 (04) : 233 - 237
  • [10] Comparison of scanning electron microscopy and optical coherence tomography for imaging of coronary bifurcation stents
    Silva, Guilherme V.
    Gahremanpour, Amir
    Attizzani, Guilherme F.
    Zeng, Yi
    Wang, Wei
    Yamamoto, Hirosada
    Kanaya, Tomoaki
    Rippy, Marian K.
    Bezerra, Hiram G.
    Costa, Marco A.
    Perin, Emerson
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (07) : 1141 - 1149