Relationship of blood pressure and pump flow in an implantable centrifugal blood pump during hypertension

被引:13
|
作者
Akimoto, T
Yamazaki, K
Litwak, P
Litwak, KN
Tagusari, O
Mori, T
Antaki, JF
Kameneva, MV
Watach, MJ
Umezu, M
Tomioka, J
Kormos, RL
Koyanagi, H
Griffith, BP
机构
[1] Univ Pittsburgh, Dept Surg, McGowan Ctr, Pittsburgh, PA 15219 USA
[2] Tokyo Womens Med Coll, Dept Cardiovasc Surg, Tokyo 162, Japan
[3] SunMed Technol Res Corp, Nagano, Japan
[4] Waseda Univ, Dept Mech Engn, Tokyo, Japan
关键词
D O I
10.1097/00002480-200009000-00018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to evaluate the real time relationship between pump flow and pump differential pressure (D-P) during experimentally induced hypertension (HT). Two calves (80 and 68 kg) were implanted with the EVA-HEART centrifugal blood pump (SunMedical Technology Research Corp., Nagano, Japan) under general anesthesia. Blood pressure (BP) in diastole was increased to 100 mm Hg by norepinephrine to simulate HT. Pump flow, D-P, EGG, and BP were measured at pump speeds of 1,800, 2,100, and 2,300 rpm. All data were separated into systole and diastole, and pump flow during HT was compared with normotensive (NT) conditions at respective pump speeds. Diastolic BP was increased to 99.3 +/- 4.1 mm Hg from 66.5 +/- 4.4mm Hg (p < 0.01). D-P in systole was under 40 mm Hg (range of change was 10 to 40 mm Hg) even during HT. During NT, the average systolic pump flow volume was 60% of the total pump flow. However, during HT, the average systolic pump flow was 100% of total pump flow volume, although the pump flow volume in systole during HT decreased (33.1 +/- 5.7 vs 25.9 +/- 4.0 ml/systole, p < 0.01). In diastole, the average flow volume through the pump was 19.6 +/- 6.9 ml/diastole during NT and -2.2 +/- 11.1 ml/diastole during HT (p < 0.01). The change in pump flow volume due to HT, in diastole, was greater than the change in pump flow in systole at each pump speed (p < 0.001). This study suggests that the decrease of mean pump flow during HT is mainly due to the decrease of the diastolic pump flow and, to a much lesser degree, systolic pump flow.
引用
收藏
页码:596 / 599
页数:4
相关论文
共 50 条
  • [1] Establishment of flow estimation for an implantable centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Takano, H
    ASAIO JOURNAL, 1997, 43 (05) : M659 - M662
  • [2] THE VIENNA IMPLANTABLE CENTRIFUGAL BLOOD PUMP
    SCHIMA, H
    TRUBEL, W
    WIESELTHALER, G
    SCHMIDT, C
    MULLER, MR
    SIEGL, H
    LOSERT, U
    WOLNER, E
    ARTIFICIAL ORGANS, 1994, 18 (07) : 500 - 505
  • [3] Mapping of pump efficiency on the pressure-flow curve of a centrifugal blood pump
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Glueck, J
    Benkowski, R
    Nose, Y
    ARTIFICIAL ORGANS, 1997, 21 (08) : 953 - 957
  • [4] Noninvasive pump flow estimation of a centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Nakatani, T
    Tatsumi, E
    Nishimura, T
    Takewa, Y
    Ohno, T
    Takano, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 651 - 654
  • [5] Flow rate and pressure head estimation in a centrifugal blood pump
    Funakubo, A
    Ahmed, S
    Sakuma, I
    Fukui, Y
    ARTIFICIAL ORGANS, 2002, 26 (11) : 985 - 990
  • [6] Design, Manufacturing and Tests of an Implantable Centrifugal Blood Pump
    Bock, Eduardo
    Antunes, Pedro
    Uebelhart, Beatriz
    Leao, Tarcisio
    Fonseca, Jeison
    Cavalheiro, Andre
    Santos Filho, Diolino
    Cardoso, Jose Roberto
    Utiyama, Bruno
    Leme, Juliana
    Silva, Cibele
    Andrade, Aron
    Arruda, Celso
    TECHNOLOGICAL INNOVATION FOR SUSTAINABILITY, 2011, 349 : 410 - +
  • [7] Performances of a newly developed implantable centrifugal blood pump
    Tsukiya, T.
    Taenaka, Y.
    Tatsumi, E.
    Takano, H.
    Konishi, Y.
    Murai, G.
    Masuzawa, T.
    Okada, Y.
    ASAIO Journal, 2000, 46 (02)
  • [8] Performance of a newly developed implantable centrifugal blood pump
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2001, 47 (05) : 559 - 562
  • [9] Development of an implantable centrifugal blood pump for circulatory assist
    Wakisaka, Y
    Taenaka, Y
    Chikanari, K
    Okuzono, Y
    Endo, S
    Takano, H
    ASAIO JOURNAL, 1997, 43 (05) : M608 - M614
  • [10] The role of diastolic pump flow in centrifugal blood pump hemodynamics
    Akimoto, T
    Litwak, KN
    Yamazaki, K
    Litwak, P
    Kihara, S
    Tagusari, J
    Yamazaki, S
    Kameneva, MV
    Watach, MJ
    Umezu, M
    Tomioka, J
    Kormos, RL
    Koyanagi, T
    Griffith, BP
    ARTIFICIAL ORGANS, 2001, 25 (09) : 724 - 727