In view of STATCOM operation analysis, special attention must be paid to the operation with unbalanced network voltages. In this paper a control algorithm that enables STATCOM operation with unbalanced voltages is presented. The algorithm is based on the compensator mathematical model in the d-q coordinate system. In case of an unbalanced voltage sag the compensator unbalances the generated voltages to limit the negative sequence currents. The problem of low-order harmonics generation is solved with the use of appropriate switching function modulation that enables the use of a relatively small capacitor on the dc side. The proposed algorithm was tested by means of simulation of STATCOM operation in the PSCAD program. The algorithm shows a good transient response also in the case of relatively deep voltage sags.
引用
收藏
页码:149 / +
页数:3
相关论文
共 50 条
  • [21] Grid Current Control Methods by Using Compensation Voltages Under Distorted and Unbalanced Grid Voltages
    Thanh-Vu Tran
    Chun, Tae-Won
    Lee, Hong-Hee
    Kim, Heung-Geun
    Nho, Eui-Cheol
    2014 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2014, : 901 - 906
  • [22] Research on Control Strategy of Cascade STATCOM under Unbalanced System Voltage
    Zhang Jiao
    Niu Xingyan
    Du Mingjun
    Qi Zefeng
    Li Qirui
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [23] Software Sensor-Based STATCOM Control Under Unbalanced Conditions
    Leon, Andres E.
    Manuel Mauricio, Juan
    Solsona, Jorge A.
    Gomez-Exposito, Antonio
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1623 - 1632
  • [24] A novel control method for D-STATCOM under unbalanced conditions
    Fu, Xiangyun
    Wang, Jianze
    Ji, Yanchao
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2048 - +
  • [25] Individual phase control of D-STATCOM under unbalanced compensation
    Wang, Jian-Ze
    Fu, Xiang-Yun
    Ji, Yan-Chao
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2007, 27 (09): : 27 - 30
  • [26] A Control Scheme for H-bridge STATCOM Under Unbalanced System
    Jie, Zhou
    Yong, Wang
    Liu Ruidong
    Shi Zhiyong
    2012 2ND INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2012, : 98 - 101
  • [27] A DC Capacitor Voltages Balancing Control Strategy for Cascade D-STATCOM
    Xie, Pengkang
    Yang, Kun
    Zhao, Chun
    Chen, Guozhu
    2013 1ST INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC 2013), 2013, : 859 - 863
  • [28] Control of Active and Reactive Power Ripple to Mitigate Unbalanced Grid Voltages
    Kabiri, Roozbeh
    Holmes, Donald Grahame
    McGrath, Brendan Peter
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (02) : 1660 - 1668
  • [29] Control an active filter in unbalanced non-sinusoidal source voltages
    Kim, HS
    PCC-OSAKA 2002: PROCEEDINGS OF THE POWER CONVERSION CONFERENCE-OSAKA 2002, VOLS I - III, 2002, : 766 - 771
  • [30] Direct power control of voltage source inverters with unbalanced grid voltages
    Eloy-Garcia, J.
    Arnaltes, S.
    Rodriguez-Amenedo, J. L.
    IET POWER ELECTRONICS, 2008, 1 (03) : 395 - 407