Investigation of punching shear behavior of flat slabs with different types and arrangements of shear reinforcement

被引:16
|
作者
Shatarat, Nasim [1 ]
Salman, Donia [2 ]
机构
[1] Univ Jordan, Dept Civil Engn, Amman 11942, Jordan
[2] Al Zaytoonah Univ Jordan, Dept Civil Engn, Amman 11733, Jordan
关键词
Reinforced concrete slabs; Punching shear; Rectangular spiral stirrups; Circular spiral stirrups; ACI; 318-19; CONCRETE SLABS; STRENGTH; TESTS; BEAMS;
D O I
10.1016/j.cscm.2022.e01028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Punching shear behavior is experimentally investigated through testing a total of thirteen rein-forced concrete flat slabs. Four different types of punching shear reinforcement configurations are examined, namely, ordinary closed rectangular stirrups (ST group), rectangular spiral stirrups (RSP group), advanced rectangular spiral stirrups (ARSP group), and circular spiral stirrups (SP group). Each configuration included three different spacings of 100, 150 and 200 mm. In addi-tion, a reference slab specimen is cast without any punching shear reinforcement. The test results indicated that the circular spiral reinforcement scheme has the highest enhancement with regard to the punching shear capacity compared to the other reinforcement schemes. The percentage of enhancement of the SP group compared to the reference specimen ranges between 23% and 30%. For the other three different rectangular schemes, the enhancement of the punching shear strength for the RSP group and the ARSP group is in the range of 15-23% and 16-25%, respectively. Finally, the punching shear capacity of the ST group increased by 9-13% compared to the reference specimen. The shear carrying capacity of the specimens is also calculated using the ACI 318-19 code and Eurocode 2 equations. The results showed that both codes are capable of predicting the shear carrying capacity for all the schemes. Also, although both codes are con-servative, the Eurocode 2 gives a better estimate of the shear carrying capacity than the ACI 318-19 code.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Punching Shear Behavior of Two-Way Slabs Reinforced with FRP Shear Reinforcement
    Hassan, Mohamed
    Ahmed, Ehab A.
    Benmokrane, Brahim
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (01)
  • [42] The Maximum Punching Shear Resistance of Flat Slabs
    Halvonik, Jaroslav
    Fillo, L'udovit
    CONCRETE AND CONCRETE STRUCTURES 2013 - 6TH INTERNATIONAL CONFERENCE, SLOVAKIA, 2013, 65 : 376 - 381
  • [43] The maximum punching shear resistance of flat slabs
    Majtanova, L.
    Hanzel, J.
    Halvonik, J.
    ADVANCES AND TRENDS IN ENGINEERING SCIENCES AND TECHNOLOGIES II, 2017, : 193 - 199
  • [44] Punching shear of flat slabs subjected to earthquakes
    Megally, S
    Ghali, A
    CANADIAN SOCIETY FOR CIVIL ENGINEERING, VOL I, PROCEEDINGS, 1999, : 295 - 304
  • [45] Punching of Reinforced Concrete Flat Slabs with Double-Headed Shear Reinforcement
    Ferreira, Mauricio P.
    Melo, Guilherme S.
    Regan, Paul E.
    Vollum, Robert L.
    ACI STRUCTURAL JOURNAL, 2014, 111 (02) : 363 - 374
  • [46] Punching shear capacity of expanded polystyrene (EPS) lightweight concrete flat slabs without shear reinforcement
    Ahmed, Faris Rashied
    ADVANCES IN MECHANICAL ENGINEERING, 2023, 15 (09)
  • [47] Non-destructive inspection of punching shear reinforcement in concrete flat slabs
    Hugenschmidt, Johannes
    Fischer, Andreas
    Schiavi, Lucio
    BETON- UND STAHLBETONBAU, 2014, 109 (04) : 257 - U28
  • [48] Post-installed punching shear reinforcement for strengthening of flat-slabs
    Muttoni, A.
    Ruiz, M. Fernandez
    Kunz, J.
    BAUINGENIEUR, 2008, 83 : 503 - 511
  • [50] Effects of openings on the punching shear strength of RC flat-plate slabs without shear reinforcement
    Ha, Taehun
    Lee, Myung-Ho
    Park, Jonghwan
    Kim, Dae-Jin
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2015, 24 (15): : 895 - 911