Portable detection of Staphylococcus aureus using personal glucose meter based on hybridization chain reaction strategy

被引:35
|
作者
Yang, Yuemeng [1 ]
Wu, Tingting [1 ]
Xu, Li-Ping [1 ]
Zhang, Xueji [1 ,2 ]
机构
[1] Univ Sci & Technol Beijing, Res Ctr Bioengn & Sensing Technol, Sch Chem & Biol Engn, Beijing Key Lab Bioengn & Sensing Technol, Beijing 100083, Peoples R China
[2] Shenzhen Univ, Hlth Sci Ctr, Sch Biomed Engn, Shenzhen 518060, Guangdong, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Personal glucose meter; Staphylococcus aureus; Hybridization chain reaction strategy; Portable; QUANTITATIVE DETECTION; METHICILLIN-RESISTANT; NANOPARTICLES; BIOSENSOR; APTASENSOR; READOUT; SENSOR;
D O I
10.1016/j.talanta.2021.122132
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Staphylococcus aureus is one of the most important food-borne bacterial pathogens and causes numerous illnesses. In this work, we report a sensitive and highly selective magnetic-aptamer biosensor based on a personal glucose meter (PGM) platform for the detection of Staphylococcus aureus. The aptamer for Staphylococcus aureus was immobilized on the magnetic bead by hybridization with the capture probe P. In the presence of Staphylococcus aureus, the aptamer was dissociated from the magnetic bead. Then the capture probe was exposed and could be hybridized with a biotinylated probe to trigger the DNA hybridization chain reaction (HCR), thus achieving the signal amplification. The concentration of streptavidin-labeled invertase can be read by PGM, thus can lead to the portable quantitative detection of Staphylococcus aureus. After optimization of various conditions, 5 mu M probe P, the MB-P reaction time for 36 h, the competition time for 60 min, 0.5 mu M H1 & H2, 0.5 M sucrose and the sucrose invertase catalytic reaction time for 50 min was chosen to achieve the better sensor performance. Under the optimal conditions, the fabricated sensor offers high sensitivity with the limit of detection about 2 CFU/mL. This sensitive PGM based sensor could successfully evaluate the Staphylococcus aureus concentration in real food samples, and the results are consistent with those obtained by using plate counting methods. Moreover, the PGM sensor can greatly reduce the required time compared to the plate counting methods. The fabricated sensor supplies an ideal solution for rapid portable detection of bacterial pathogens and holds its potential use in the quality control for agriculture and food enterprises, entry-exit inspection and quality testing for food.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] DETECTION OF STAPHYLOCOCCUS-EPIDERMIDIS AND STAPHYLOCOCCUS-AUREUS IN VITREOUS BY POLYMERASE CHAIN-REACTION
    JETT, BD
    SHEPARD, B
    GILMORE, MS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S788 - S788
  • [42] Facile method for enrofloxacin detection in milk using a personal glucose meter
    Kwon, Donghoon
    Lee, Hyeonjeong
    Yoo, Hojin
    Hwang, Jeongin
    Lee, Dongkyu
    Jeon, Sangmin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 935 - 939
  • [43] Portable and sensitive detection of non-glucose target by enzyme-encapsulated metal-organic-framework using personal glucose meter
    Cao, Yunzhe
    Mo, Fengye
    Liu, Yahua
    Liu, Yu
    Li, Gaiping
    Yu, Wenqian
    Liu, Xiaoqing
    BIOSENSORS & BIOELECTRONICS, 2022, 198
  • [44] Highly sensitive detection of lipopolysaccharides using an aptasensor based on hybridization chain reaction
    Xie, Peiyan
    Zhu, Longjiao
    Shao, Xiangli
    Huang, Kunlun
    Tian, Jingjing
    Xu, Wentao
    SCIENTIFIC REPORTS, 2016, 6
  • [45] Highly sensitive detection of lipopolysaccharides using an aptasensor based on hybridization chain reaction
    Peiyan Xie
    Longjiao Zhu
    Xiangli Shao
    Kunlun Huang
    Jingjing Tian
    Wentao Xu
    Scientific Reports, 6
  • [46] An Insulated Isothermal Polymerase Chain Reaction Method for Detection of Staphylococcus aureus in Foods
    Li C.
    Zeng B.
    Zhao Y.
    Tang C.
    Chen J.
    Liu J.
    Zhu C.
    Zeng Y.
    Yu J.
    Tang J.
    Shipin Kexue/Food Science, 2022, 43 (02): : 339 - 345
  • [47] A novel method for sensitive, low-cost and portable detection of hepatitis B surface antigen using a personal glucose meter
    Taebi, Saeed
    Keyhanfar, Mehrnaz
    Noorbakhsh, Abdollah
    JOURNAL OF IMMUNOLOGICAL METHODS, 2018, 458 : 26 - 32
  • [48] Magnetic bead-liposome hybrids enable sensitive and portable detection of DNA methyltransferase activity using personal glucose meter
    Zhang, Youna
    Xue, Qingwang
    Liu, Jifeng
    Wang, Huaisheng
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 537 - 544
  • [49] Detection of methicillin-resistant Staphylococcus aureus using a gold nanoparticle-based colourimetric polymerase chain reaction assay
    Chan, Wai-Sing
    Tang, Bone S. F.
    Boost, Maureen V.
    Chow, Chit
    Leung, Polly H. M.
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 105 - 111
  • [50] A highly sensitive and specific fluorescent strategy for the detection of Visfatin based on nonlinear hybridization chain reaction
    Liu, Feifei
    Yuan, Yin
    Zhang, Wanliang
    Fu, Yafei
    Yang, Mengliu
    Yang, Gangyi
    Liu, Hua
    Shen, Huawei
    Li, Ling
    MICROCHEMICAL JOURNAL, 2023, 190