Intravascular Ultrasound Findings in Patients With Very Late Stent Thrombosis After Either Drug-Eluting or Bare-Metal Stent Implantation

被引:129
|
作者
Lee, Cheol Whan
Kang, Su-Jin
Park, Duk-Woo
Lee, Seung-Hwan
Kim, Young-Hak
Kim, Jae-Joong
Park, Seong-Wook
Mintz, Gary S. [2 ]
Park, Seung-Jung [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Div Cardiol, Dept Med, Seoul 138736, South Korea
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
imaging; stent; thrombosis; MALAPPOSITION; APPOSITION; EFFICACY; SAFETY; RISK;
D O I
10.1016/j.jacc.2009.10.077
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study compared intravascular ultrasound (IVUS) findings at drug-eluting stent (DES) and bare-metal stent (BMS) sites in patients with very late stent thrombosis (VLST). Background VLST is being increasingly identified since the introduction of DES. VLST can also develop after BMS placement, but the underlying mechanisms remain unknown. Methods A total of 30 consecutive VLST patients with acute myocardial infarction (DES, n = 23; BMS, n = 7) were enrolled. Patients underwent IVUS examination before coronary angioplasty. Results The baseline characteristics were similar for the 2 groups, with the exception of reference vessel size, lesion length, stent length, minimal lumen diameter, and diameter stenosis after the procedure. Overall, VLST occurred at a mean 50.8 +/- 36.2 months after the index procedure, and occurred earlier after DES than BMS (33.2 +/- 12.5 months vs. 108.4 +/- 26.5 months, p < 0.001). IVUS variables were generally similar for the 2 groups. However, plaque burden at the distal reference segment, stent, and neointimal area of the in-stent segment were smaller in the DES group. Stent malapposition was observed in 73.9% of DES patients, but in no BMS patients (p = 0.001). Disease progression with neointimal rupture within the stent was observed in 10 DES patients (43.5%) and 7 BMS patients (100%; p = 0.010). Conclusions Stent malapposition was unique to DES-related VLST, whereas disease progression with neointimal rupture was more common in BMS patients. These findings suggest that different biological mechanisms underlie VLST development depending upon the stent type. (J Am Coll Cardiol 2010;55:1936-42) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1936 / 1942
页数:7
相关论文
共 50 条
  • [21] Predictors for very late stent thrombosis after drug-eluting stent implantation in diabetic patients
    Voudris, Vassilis
    Karyofillis, Panagiotis
    Thomopoulou, Sophia
    Patsilinakos, Sotitrios
    Manginas, Athanasios
    Spargias, Constantinos
    Pavides, Gregory
    Cokkinos, Dennis V.
    CIRCULATION, 2007, 116 (16) : 567 - 567
  • [22] Predictors for very late stent thrombosis after drug-eluting stent implantation in diabetic patients
    Vouidris, Vassilis
    Kariofillis, Panagiotis
    Thomopoulou, Sophia
    Patsilinakos, Sotiris
    Manginas, Athanasios
    Spargias, Constantinos
    Pavlides, Gregory
    Cokkinos, Dennis V.
    EUROINTERVENTION, 2009, 4 (04) : 485 - 491
  • [23] Incidence and very long- term outcomes of stent thrombosis after bare-metal or drug-eluting stent implantation: a retrospective analysis
    Pullara, A.
    Longo, G.
    Gonella, A.
    D'Ascenzo, F.
    Zoccai, G. Biondi
    Moretti, C.
    Sciuto, F.
    Omede, P. L.
    Bollati, M.
    Gaita, F.
    Sheiban, I.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (01): : 1 - 9
  • [24] Difference in Clinical and Angiographic Characteristics of Very Late Stent Thrombosis Between Drug-Eluting and Bare-Metal Stent Implantations
    Kubo, Shunsuke
    Kadota, Kazushige
    Ozaki, Masatomo
    Ichinohe, Tahei
    Eguchi, Haruki
    Miyake, Koshi
    Hyodo, Yusuke
    Saito, Naoki
    Otsuji, Hideaki
    Otsuru, Suguru
    Hasegawa, Daiji
    Shigemoto, Yoshikazu
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Katoh, Harumi
    Yamamoto, Hiroyuki
    Fujii, Satoki
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    CIRCULATION JOURNAL, 2013, 77 (06) : 1453 - 1460
  • [25] Late Acquired Stent Malapposition is Higher After Drug-Eluting Stent Compared to Bare-Metal Stent Implantation and is Associated with (Very) Late Stent Thrombosis: Meta-Analysis and Systematic Review
    Hassan, Ayman K. M.
    Bergheanu, Sandrin
    Stijnen, Theo
    Van der Hoeven, Bas
    Snoep, Jaapjan
    Plevier, Josepha
    Schalij, Martin
    Jukema, J. Wouter
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 198I - 198I
  • [26] Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    Cook, Stephane
    Wenaweser, Peter
    Togni, Mario
    Billinger, Michael
    Morger, Cyrill
    Seiler, Christian
    Vogel, Rolf
    Hess, Otto
    Meier, Bernhard
    Windecker, Stephan
    CIRCULATION, 2007, 115 (18) : 2426 - 2434
  • [27] Restenosis in a Bare-Metal Stent: Drug-Eluting Balloon or Drug-Eluting Stent?
    Colombo, Antonio
    Jabbour, Richard J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04)
  • [28] Stent thrombosis with drug-eluting and bare-metal stents Reply
    Palmerini, Tullio
    Zoccai, Giuseppe Biondi
    Della Riva, Diego
    Stone, Gregg W.
    LANCET, 2012, 380 (9842): : 646 - 647
  • [29] Very Late Stent Thrombosis 11 Years after Implantation of a Drug-Eluting Stent
    Liou, Kevin
    Jepson, Nigel
    TEXAS HEART INSTITUTE JOURNAL, 2015, 42 (05) : 487 - 490
  • [30] Incidence and predictors of very late Stent thrombosis after drug-eluting stent implantation
    Suh, Jon
    Lee, Seung-Whan
    Kim, Jeong-Hoon
    Park, Duk-Woo
    Lee, Jong-Young
    Kim, Young-Hak
    Lee, Cheol Whan
    Hong, Mveong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 113L - 113L