A comparative study for reactive power capability of doubly fed induction generator and synchronous generator

被引:0
|
作者
Kumar, Sanjeev [1 ]
Singh, Omveer [2 ]
Aggarwal, S. K. [3 ]
机构
[1] Maharishi Markandeshwar Univ, Dept Elect Engn, Ambala, Haryana, India
[2] Gautam Buddh Univ, Dept Elect Engn, Greater Noida, Uttar Pradesh, India
[3] Thapar Univ, E&I Engn Dept, Patiala, Punjab, India
关键词
Wind generator; DFIG; Reactive power capability; RSC; GSC;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recent grid code particularly established for high penetration of renewable power generation in the power system demand the network support similar to conventional generator in steady state and dynamic operations. voltage instability is one of the major concerns with huge amount of wind power penetration in the existing power system which is due to insufficient amount of reactive power. Modern wind generator is used in variable speed applications equipped with power electronics converters have capability to deliver/consumer reactive power similar to conventional generator. In present work, reactive power capability possessed by doubly fed induction generator equipped wind turbine has been analyzed by considering various constraints and compared with the reactive capability of synchronous generator.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Nonlinear Adaptive Robust Control Strategy of Doubly Fed Induction Generator Based on Virtual Synchronous Generator
    Han, Jiangbei
    Liu, Zhijian
    Liang, Ning
    IEEE ACCESS, 2020, 8 : 159887 - 159896
  • [42] Active Control Scheme for Reactive Generation of Doubly Fed Induction Generator
    Feng Jinshuai
    Wang Fangzong
    2013 2ND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND MEASUREMENT, SENSOR NETWORK AND AUTOMATION (IMSNA), 2013, : 1059 - 1063
  • [43] Oscillation Damping for Wind Energy Conversion System with Doubly Fed Induction Generator Association with Synchronous Generator
    Abo-Elyousr, Farag K.
    Abbas, Hossam S.
    Yousef, Ali M.
    Quynh, Nguyen Vu
    Ali, Ziad M.
    Nazir, Muhammad Shahzad
    ENERGIES, 2020, 13 (19)
  • [44] VSC-based direct torque and reactive power control of doubly fed induction generator
    Hu, Jiabing
    Yuan, Xiaoming
    RENEWABLE ENERGY, 2012, 40 (01) : 13 - 23
  • [45] Real-Time Simulation for Active and Reactive Power Control of Doubly Fed Induction Generator
    Maharjan, Rabindra
    Kamalasadan, Sukumar
    2013 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2013,
  • [46] Reactive Power Dispatch for Loss Minimization of a Doubly Fed Induction Generator Based Wind Farm
    Zhang, Baohua
    Hu, Weihao
    Hou, Peng
    Chen, Zhe
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 1373 - 1378
  • [47] A Novel Doubly Fed Induction Generator System with Fault Ride through Capability
    Jiang, Yang
    Huang, Xiaoyan
    Fang, Youtong
    Gerada, Chris
    Goodman, Andrew
    2012 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2012), 2012,
  • [48] Fault ride through capability of doubly-FED induction generator wind power generation system
    Ma, Hongfei
    Xu, Dianguo
    Chen, Zhe
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (10): : 1228 - 1233
  • [49] Doubly-fed induction generator (DFIG) as a hybrid of asynchronous and synchronous machines
    Jiao, LW
    Ooi, BT
    Joós, G
    Zhou, FQ
    ELECTRIC POWER SYSTEMS RESEARCH, 2005, 76 (1-3) : 33 - 37
  • [50] Deadband Control of Doubly-Fed Induction Generator Around Synchronous Speed
    Tan, Yingjie
    Muttaqi, Kashem M.
    Meegahapola, Lasantha
    Ciufo, Phil
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1610 - 1621