Streak Metal Artifact Reduction Based on Sinogram Fusion and Tissue-Class Model in CT Images

被引:0
|
作者
Deng, Shuwen [1 ]
Li, Yuanjin [2 ]
Wang, Dianhua [1 ]
机构
[1] Hubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
[2] Chuzhou Univ, Comp Dept, Chuzhou 239000, Peoples R China
基金
中国国家自然科学基金;
关键词
ALGORITHM;
D O I
10.1155/2022/8021862
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The presence of streak metal artifacts seriously degrades the diagnostic value and deteriorates the qualities of CT images. Analyzing the causes and classical streak metal artifact reduction (MAR) methods, the paper proposes the streak metal artifact reduction method based on sinogram fusion and tissue-class mode for CT images (F-MAR). Firstly, the original CT images are corrected using a linear interpolation streak metal artifact reduction (L-MAR) scheme in the raw data domain. Subsequently, to preserve the edge information, the metal artifact-reduced images are then smoothed into smoothed images (tissue-class model) by using the mean filter. Segment the original CT image that contained the streak artifacts. The original CT image and the CT image that contained high-density material are projected into the original sinogram and the high density material sinogram, respectively. Secondly, the simple linear interpolation is used to correct the CT original CT image into the corrected CT image. The mean filter is applied in the corrected CT image. The corrected CT image is projected into the corrected sinogram. Thirdly, according to the position of the high density material sinogram located in the original sinogram and the corrected sinogram, the original position sinogram included in the original sinogram and the corrected position sinogram included in the corrected sinogram are, respectively, obtained. The two sinograms are fused into the fused sinogram. The fused sinogram, the original sinogram, and the high-density material sinogram are fused into the final sinogram. Finally, the filtered back projection reconstruction algorithm is used to reconstruct the final sinogram into the reconstructed CT image. The reconstructed CT image and high density material image are fused into the final image. The experimentation results show that the method proposed in the paper can obtain better correction effect than the classical correction methods in vision.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Metal Artifact Reduction in CT-Based Attenuation Correction of PET using Sobolev Sinogram Restoration
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2936 - 2942
  • [22] Fully Convolutional Networks Based Sinogram Correction for Metal Artifact Reduction
    Zhu, Linlin
    Han, Yu
    Li, Ziheng
    Xi, Xiaoqi
    Li, Lei
    Yan, Bin
    Zhu, Mingwan
    AI IN OPTICS AND PHOTONICS (AOPC 2019), 2019, 11342
  • [23] Clough-Tocher interpolation of virtual sinogram in a Delaunay triangulated grid for metal artifact reduction of PET/CT images
    Abdoli, M.
    de Long, J. R.
    Pruim, J.
    Dierckx, R. A. J. O.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3197 - 3201
  • [24] Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction
    Peng, Chengtao
    Qiu, Bensheng
    Li, Ming
    Guan, Yihui
    Zhang, Cheng
    Wu, Zhongyi
    Zheng, Jian
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [25] Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction
    Chengtao Peng
    Bensheng Qiu
    Ming Li
    Yihui Guan
    Cheng Zhang
    Zhongyi Wu
    Jian Zheng
    BioMedical Engineering OnLine, 16
  • [26] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Watzke, O
    Kalender, WA
    EUROPEAN RADIOLOGY, 2004, 14 (05) : 849 - 856
  • [27] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Oliver Watzke
    Willi A. Kalender
    European Radiology, 2004, 14 : 849 - 856
  • [28] Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques
    Selles, Mark
    van Osch, Jochen A. C.
    Maas, Mario
    Boomsma, Martijn F.
    Wellenberg, Ruud H. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [29] Metal artifact reduction in CT-based attenuation correction of PET data using the virtual sinogram concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    3rd International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2009, 2009,
  • [30] Metal Artifact Reduction in CT-Based Attenuation Correction of PET Data Using the Virtual Sinogram Concept
    Abdoli, Mehrsima
    Ay, Mohammad Reza
    Ahmadian, Alireza
    Zaidi, Habib
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1848 - +