Streak Metal Artifact Reduction Based on Sinogram Fusion and Tissue-Class Model in CT Images

被引:0
|
作者
Deng, Shuwen [1 ]
Li, Yuanjin [2 ]
Wang, Dianhua [1 ]
机构
[1] Hubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
[2] Chuzhou Univ, Comp Dept, Chuzhou 239000, Peoples R China
基金
中国国家自然科学基金;
关键词
ALGORITHM;
D O I
10.1155/2022/8021862
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The presence of streak metal artifacts seriously degrades the diagnostic value and deteriorates the qualities of CT images. Analyzing the causes and classical streak metal artifact reduction (MAR) methods, the paper proposes the streak metal artifact reduction method based on sinogram fusion and tissue-class mode for CT images (F-MAR). Firstly, the original CT images are corrected using a linear interpolation streak metal artifact reduction (L-MAR) scheme in the raw data domain. Subsequently, to preserve the edge information, the metal artifact-reduced images are then smoothed into smoothed images (tissue-class model) by using the mean filter. Segment the original CT image that contained the streak artifacts. The original CT image and the CT image that contained high-density material are projected into the original sinogram and the high density material sinogram, respectively. Secondly, the simple linear interpolation is used to correct the CT original CT image into the corrected CT image. The mean filter is applied in the corrected CT image. The corrected CT image is projected into the corrected sinogram. Thirdly, according to the position of the high density material sinogram located in the original sinogram and the corrected sinogram, the original position sinogram included in the original sinogram and the corrected position sinogram included in the corrected sinogram are, respectively, obtained. The two sinograms are fused into the fused sinogram. The fused sinogram, the original sinogram, and the high-density material sinogram are fused into the final sinogram. Finally, the filtered back projection reconstruction algorithm is used to reconstruct the final sinogram into the reconstructed CT image. The reconstructed CT image and high density material image are fused into the final image. The experimentation results show that the method proposed in the paper can obtain better correction effect than the classical correction methods in vision.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Metal Artifact Reduction in CT Using Deformable Tissue-Class Modeling
    Zhuge, Y.
    Ning, H.
    Cheng, J.
    Arora, B.
    Xie, H.
    Miller, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    Bal, Matthieu
    Spies, Lothar
    MEDICAL PHYSICS, 2006, 33 (08) : 2852 - 2859
  • [3] Metal Artifact Reduction in CT images by Sinogram TV inpainting
    Duan, Xinhui
    Zhang, Li
    Xiao, Yongshun
    Cheng, Jianping
    Chen, Zhiqiang
    Xing, Yuxiang
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3450 - +
  • [4] Metal Artifact Reduction Based on Sinogram Correction in CT
    Jeong, Kye Young
    Ra, Jong Beom
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3480 - 3483
  • [5] A metal artifact reduction scheme in CT by a Poisson fusion sinogram based postprocessing method
    Tang, Hui
    Lin, Yu Bing
    Sun, Guo Yan
    Bao, Xu Dong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (02) : 245 - 257
  • [6] A CT metal artifact reduction algorithm based on sinogram surgery
    Jeon, Soomin
    Lee, Chang-Ock
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (03) : 413 - 434
  • [7] Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images
    Yu, Lequan
    Zhang, Zhicheng
    Li, Xiaomeng
    Xing, Lei
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (01) : 228 - 238
  • [8] Metal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentation
    Kaewlek, Titipong
    Koolpiruck, Diew
    Thongvigitmanee, Saowapak
    Mongkolsuk, Manus
    Thammakittiphan, Sastrawut
    Tritrakarn, Siri-on
    Chiewvit, Pipat
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (06) : 649 - 666
  • [9] Metal Artifact Reduction in CT Based on Adaptive Steering Filter and Nonlocal Sinogram Inpainting
    Li, Yinsheng
    Bao, Xudong
    Yin, Xindao
    Chen, Yang
    Luo, Limin
    Chen, Wufan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 380 - 383
  • [10] Metal Artifact Reduction in Dual Energy CT by Sinogram Segmentation Based on Active Contour Model and TV Inpainting
    Xue, Hui
    Zhang, Li
    Xiao, Yongshun
    Chen, Zhiqiang
    Xing, Yuxiang
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 904 - 908