Mass diffusion coefficient measurement for vitreous humor using FEM and MRI

被引:8
|
作者
Rattanakijsuntorn, Komsan [1 ]
Penkova, Anita [2 ]
Sadhal, Satwindar S. [2 ]
机构
[1] Ubon Ratchathani Univ, Fac Engn, Dept Mech Engn, 85 Sathonlamark Rd, Warinchamrap 34190, Ubon Ratchathan, Thailand
[2] Univ Southern Calif, Aerosp & Mech Engn Dept, Los Angeles, CA 90089 USA
关键词
INTRAVITREAL; INJECTION; DELIVERY;
D O I
10.1088/1757-899X/297/1/012024
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In early studies, the 'contour method' for determining the diffusion coefficient of the vitreous humor was developed. This technique relied on careful injection of an MRI contrast agent (surrogate drug) into the vitreous humor of fresh bovine eyes, and tracking the contours of the contrast agent in time. In addition, an analytical solution was developed for the theoretical contours built on point source model for the injected surrogate drug. The match between theoretical and experimental contours as a least square fit, while floating the diffusion coefficient, led to the value of the diffusion coefficient. This method had its limitation that the initial injection of the surrogate had to be spherical or ellipsoidal because of the analytical result based on the point-source model. With a new finite element model for the analysis in this study, the technique is much less restrictive and handles irregular shapes of the initial bolus. The fresh bovine eyes were used for drug diffusion study in the vitreous and three contrast agents of different molecular masses: gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA, 938 Da), non-ionic gadoteridol (Prohance, 559 Da), and bovine albumin conjugated with gadolinium (Galbumin, 74 kDa) were used as drug surrogates to visualize the diffusion process by MRI. The 3D finite element model was developed to determine the diffusion coefficients of these surrogates with the images from MRI. This method can be used for other types of bioporous media provided the concentration profile can be visualized (by methods such as MRI or fluorescence).
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Vitreous Humor Diffusion Changes in Behcet's Disease and Multiple Sclerosis
    Inal, Mikail
    Sahan, Mehmet Hamdi
    Ergun, Ufuk
    Bilgili, Mirace Yasemin Karadeniz
    CURRENT MEDICAL IMAGING, 2018, 14 (06) : 933 - 937
  • [32] Diffusion MRI of normal pancreas: variations and reproducibility of the measurement of apparent diffusion coefficient at 1.5 and 3 Tesla
    Barral, M.
    Soyer, P.
    Ben Hassen, W.
    Gayat, E.
    Aout, M.
    Chiaradia, M.
    Rahmouni, A.
    Luciani, A.
    JOURNAL DE RADIOLOGIE DIAGNOSTIQUE ET INTERVENTIONNELLE, 2013, 94 (04) : 433 - 443
  • [33] Role of Diffusion MRI and Apparent Diffusion Coefficient Measurement in the Diagnosis, Staging and Pathological Classification of Bladder Tumors
    Daggulli, Mansur
    Onur, Mehmet Ruhi
    Firdolas, Fatih
    Onur, Rahmi
    Kocakoc, Ercan
    Orhan, Irfan
    UROLOGIA INTERNATIONALIS, 2011, 87 (03) : 346 - 352
  • [34] MEASUREMENT OF AN ANOMALOUS DIFFUSION COEFFICIENT
    THOMASSEN, KI
    PHYSICS OF FLUIDS, 1966, 9 (03) : 626 - +
  • [35] MEASUREMENT OF DIFFUSION COEFFICIENT OF RADIUM A
    RAABE, OG
    NATURE, 1968, 217 (5134) : 1143 - +
  • [36] VITREOUS HUMOR DIFFUSION MEASUREMENTS FROM DIFFUSION-WEIGHTED IMAGING IN IDIOPATHIC INTRACRANIAL HYPERTENSION
    Cagli, Bekir
    Tuncel, Sedat Alpaslan
    Yilmaz, Erdem
    Tekatas, Aslan
    Ermis, Veli
    IDEGGYOGYASZATI SZEMLE-CLINICAL NEUROSCIENCE, 2016, 69 (11-12): : 405 - 410
  • [37] MEASUREMENT OF DIFFUSION-COEFFICIENT USING A CLOSED CAPILLARY TECHNIQUE
    WRIGHT, JE
    STEVENS, GW
    KELLY, ED
    WHITE, LR
    AICHE JOURNAL, 1994, 40 (02) : 365 - 368
  • [38] Measurement of gas diffusion coefficient using photonic crystal fiber
    Hoo, YL
    Jin, W
    Ho, HL
    Wang, DN
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2003, 15 (10) : 1434 - 1436
  • [39] Measurement of enhanced mass transfer coefficient in tube by limiting diffusion current technique
    College of Chemistry and Chemical Engineering, Nanjing University of Technology, Nanjing 210009, China
    Shiyou Huagong, 2007, 7 (712-715):
  • [40] Impact of measurement method on interobserver variability of apparent diffusion coefficient of lesions in prostate MRI
    Takahashi, Hiroaki
    Yoshida, Kotaro
    Kawashima, Akira
    Lee, Nam Ju
    Froemming, Adam T.
    Adamo, Daniel A.
    Khandelwal, Ashish
    Bolan, Candice W.
    Heller, Matthew T.
    Hartman, Robert P.
    Kim, Bohyun
    Philbrick, Kenneth A.
    Carter, Rickey E.
    Mynderse, Lance A.
    Humphreys, Mitchell R.
    Cai, Jason C.
    Takahashi, Naoki
    PLOS ONE, 2022, 17 (05):