Noise level analysis in buffer rod geometries for ultrasonic sensors

被引:5
|
作者
Garcia-Alvarez, J. [1 ]
Yanez, Y. [1 ]
Prego, J. L. [1 ]
Turo, A. [1 ]
Chavez, J. A. [1 ]
Garcia, M. J. [1 ]
Salazar, J. [1 ]
机构
[1] Politech Univ Catalonia, Dept Elect Engn, EUETIB, Barcelona 08036, Spain
关键词
ultrasound; sensor; buffer rod; noise level; batter;
D O I
10.1016/j.ultras.2006.05.106
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This work presents an ultrasonic sensor for on-line batter monitoring with low-noise design considerations. The density and the compressibility of the batter vary as a function of mixing time and are strongly related to the quality of the final product. Traditionally, a batter sample of a fixed volume is removed and weighted in order to determine its density. This is a time consuming process. Benefits to the industry of on-line measuring techniques include better control of product quality, improving processing efficiencies and reduction in wastage. In this paper low-noise design considerations are accounted for an ultrasonic sensor based on a piezoceramic disk mounted between two reference buffer rods of acrylic resin to measure the acoustic impedance of the batter. Measuring the acoustic impedance changes of the batter its compressibility and density can be monitored. Spurious echoes generated at different parts of the buffer rods boundary strongly affect accuracy and reliability of the measurements, and are considered as noise. The influence of buffer rods geometry on noise level is studied using simulations and afterwards justified experimentally. Design aspects such as buffer rods length and radius, piezoceramic disk frequency and radius are discussed and their influence on noise level is shown. Finally, strategies for optimum geometry design of the ultrasonic sensor are given. (c) 2006 Elsevier B. V. All rights reserved.
引用
收藏
页码:E1093 / E1100
页数:8
相关论文
共 50 条
  • [1] Optimization of buffer rod geometry for ultrasonic sensors with reference path
    Hoppe, N
    Püttmer, A
    Hauptmann, P
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (02) : 170 - 178
  • [2] Clad buffer rod sensors for liquid metals
    Jen, CK
    Ihara, I
    ADVANCED SENSORS FOR METALS PROCESSING, 1999, : 275 - 285
  • [3] Ultrasonic Level Sensors
    不详
    ATP EDITION, 2008, (11): : 85 - 85
  • [4] Development of ultrasonic techniques with buffer rod in molten aluminum
    Ono, Y
    Moisan, JF
    Jen, CK
    França, DR
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 805 - 810
  • [5] Development of the ultrasonic buffer rod for the molten glass measurement
    Ihara, Tomonori
    Tsuzuki, Nobuyoshi
    Kikura, Hiroshige
    PROGRESS IN NUCLEAR ENERGY, 2015, 82 : 176 - 183
  • [6] BUFFER-ROD SYSTEM FOR ULTRASONIC ATTENUATION MEASUREMENTS
    PAPADAKIS, EP
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1968, 44 (05): : 1437 - +
  • [7] Noise analysis in air-coupled PVDF ultrasonic sensors
    Fiorillo, AS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (06) : 1432 - 1437
  • [8] UTILIZATION OF A BUFFER ROD WITH ULTRASONIC PULSE-ECHO-OVERLAP TECHNIQUE
    TRIVISONNO, J
    FELICE, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (10): : 1545 - 1545
  • [9] Effect of Boundary Shape on Performance of the Ultrasonic Buffer Rod Without Clad
    Wu, M.
    Zhang, D.
    Chen, Z.
    Li, Y.
    JOURNAL OF TESTING AND EVALUATION, 2017, 45 (04) : 1222 - 1230
  • [10] Ultrasonic studies of n-Ge sample by buffer-rod
    Petculescu, P.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2006, 8 (04): : 1507 - 1511