Prediction of entrained droplet fraction in co-current annular gas-liquid flow in vertical pipes

被引:34
|
作者
Aliyu, Aliyu M. [1 ]
Almabrok, Almabrok A. [2 ]
Baba, Yahaya D. [3 ]
Archibong, Archibong-Eso [4 ]
Lao, Liyun [4 ]
Yeung, Hoi [4 ]
Kim, Kyung Chun [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, Busan 609735, South Korea
[2] Sirte Univ, Fac Engn, Dept Petr Engn, Sirte, Libya
[3] Afe Babalola Univ, Dept Chem & Petr Engn, PMB 5454, Ado Ekiti, Nigeria
[4] Cranfield Univ, Oil & Gas Engn Ctr, Cranfield MK43 0AL, Beds, England
基金
新加坡国家研究基金会;
关键词
Droplet entrainment; Large diameter pipes; Two-phase flow; Sauter mean diameter; Wire Mesh Sensor; 2-PHASE FLOW; MODEL; PHASE; DIAMETER; TRANSITIONS; DEPOSITION; STEADY; WAVES; ONSET; RATES;
D O I
10.1016/j.expthermflusci.2017.03.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The entrained droplet fraction is an important parameter in annular two-phase flow, as its correlations are key inputs in flow simulation codes for the prediction of pressure drop and critical heat flux or dryout. Investigators have stressed the importance of extending the validity range of current correlations so that more conditions are covered. This could be achieved for example by including fluids with higher viscosities, a wider range of operating pressures, and increase in the size of pipes used for experiments (most of the data in the literature are from pipes of 50 mm diameter and below). In attempt to improve the latter, experiments were conducted in a 101.6 mm gas liquid flow loop at Cranfield University's Oil and Gas Engineering Laboratory and data on the fraction of droplets were collected in the annular flow regime by measuring the film velocity, from which the droplet fraction was calculated. Comparison of the film velocity by this method and by a mass balance showed close agreement. A capacitance Wire Mesh Sensor was used for flow visualisation in order to distinguish between annular and churn flow. In order to arrive at an improved correlation, over 1300 data points were gathered from other published works. These include air water studies where large pipes of up to 127 mm in diameter were used. The others were from small-diameter pipes and for refrigerant, steam water, air water, and air glycerine flows. Since in the annular regime, the gas flow entrains liquid droplets into the core, their presence alters the properties of the gas core. Therefore, accurate predictions are pivotal for the energy efficient design and operation of facilities in the petroleum and nuclear power industry. The correlation obtained here showed good agreement with the collected databank. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:287 / 304
页数:18
相关论文
共 50 条
  • [21] Study on void fraction in vertical co-current upward and downward two-phase gas-liquid flow - I: Experimental results
    Jiang, Yijun
    Rezkallah, Kamiel S.
    Chemical Engineering Communications, 1993, 126 : 221 - 243
  • [22] Droplet entrainment correlation in vertical upward co-current annular two-phase flow
    Sawant, Pravin
    Ishii, Mamoru
    Mori, Michitsugu
    NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (06) : 1342 - 1352
  • [23] A prediction method for entrained liquid fraction in adiabatic gas-liquid flow at high reduced pressure
    Minko, M. V.
    Yagov, V. V.
    INTERNATIONAL CONFERENCE PROBLEMS OF THERMAL PHYSICS AND POWER ENGINEERING (PTPPE-2017), 2017, 891
  • [24] Modeling Liquid Droplet Sizes in Gas-Liquid Annular Flow
    Karatayev, Kanat
    Fan, Yilin
    ENERGIES, 2024, 17 (13)
  • [25] Dynamics of co-current gas-liquid film flow through a slippery channel
    Vellingiri, Rajagopal
    PHYSICS OF FLUIDS, 2023, 35 (03)
  • [26] ONSET OF INTERFACIAL WAVE FORMATION IN CO-CURRENT GAS-LIQUID STRATIFIED FLOW
    CHOU, CH
    CHARLES, ME
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1968, 46 (02): : 143 - &
  • [27] CO-CURRENT STRATIFIED GAS-LIQUID FLOW IN A HORIZONTAL PIPE WITH DISCHARGING BRANCHES
    Bowden, Robert
    Saleh, Wael F.
    Hassan, Ibrahim
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 9, PTS A-C, 2010, : 1795 - 1802
  • [28] Flow characteristic and separation performance of co-current gas-liquid vortex separator
    Gao, Jinming
    Jin, Weixing
    E, Chenglin
    Fan, Yipin
    Lu, Chunxi
    POWDER TECHNOLOGY, 2024, 443
  • [29] Experimental study on a co-current gas-liquid down flow contactor with gas entrainment by a liquid jet
    Maalej, S
    Benadda, B
    Dabaliz, A
    Otterbein, M
    CHEMICAL ENGINEERING & TECHNOLOGY, 1999, 22 (12) : 1043 - 1049
  • [30] Experimental study on a co-current gas-liquid down flow contractor with gas entrainment by a liquid jet
    Laboratoire d'Analyse Environementale des Procedes et des Systemes Industriels LAEPSI - INSA de Lyon, 20 av. A. Einstein, 69621, villeurbanne, France
    Chem. Eng. Technol., 12 (1043-1049):